Latest ArticlesThe meltable polytetrafluoroethylene (PFA) was used as the matrix resin. Firstly, the PFA resin was modified by blending and filling with polymer and inorganic fillers to prepare suspension. Then, the suspension was coated and sintered in turn to prepare fluororesin-based film. Finally, the fluororesin-based film and copper foil were pressed together to prepare flexible copper clad laminate (FCCL). The results show that the prepared FCCL has 0.001 5 (10 GHz) of dielectric loss, 38 MPa of tensile strength, 0.05% of water absorption rate, greater than 1.0 kgf/cm of peel strength, and there is no delamination, oxidation, foaming in the soldering resistance test (300℃, 10 s, 3 times), which indicates that the FCCL has better overall performance.
Infrared temperature rise detection is an effective means to screen faulty composite insulators. However, the causes of abnormal heating of composite insulators are diverse, and not all causes will evolve into malignant faults. Therefore, it is particularly important to distinguish the abnormal heating caused by different causes for the safe, stable, and economic operation of power grid. In this paper, the physical and chemical properties of two 220 kV retreated composite insulators with different heating characteristics were studied by SEM and FTIR, and their dielectric properties were also studied. The results show that the causes of different abnormal temperature rise are different. For the composite insulator whose heating part is concentrated at the end of high-voltage end and temperature rise is lower than 5℃, the epoxy resin of the core rod at the heating part has no obvious degradation, and the dielectric constant and dielectric loss factor have no obvious increase, while the sheath has holes and shallow microcracks, and the dielectric constant and dielectric loss factor increase with the increase of humidity. For the composite insulator whose heating part extends to multiple umbrella skirts and temperature rise is up to 40 ℃, the epoxy resin of the core rod has obvious degradation, and the dielectric constant and dielectric loss factor are 3.67 times and 79.4 times bigger than those of the normal part, respectively.
On the basis of the statistics of bird damage accidents and drainage line faults in Ningxia, the causes of drainage line faults caused by bird dropping were analyzed. The metal conductor was used to simulate bird dropping. Under the condition of power frequency, the flashover characteristics of insulated drainage lines with different structural parameters were studied. Combined with simulation analysis, the influence of insulation thickness, conductor diameter, end shape and other parameters on the flashover characteristics of insulated drainage lines was obtained. The results show that compared with the diameter of conductor, the thickness of insulation layer has big effect on the flashover characteristics of the insulation drainage line, and within a certain range, the greater the thickness of insulation layer, the greater the flashover voltage. The flashover voltage along the insulation drainage line is not always positively correlated with the increase of surface distance. Within a certain range, the flashover voltage increases with the increase of surface distance d and then tends to stable and close to a peak value. The installation of terminal head can increase the creepage distance along the surface of insulation drainage line, effectively improve the flashover voltage of the insulation drainage line, and effectively hinder the development of surface arc, which has a significant improvement on the surface flashover of insulation drainage line.
In order to study the surface potential and electric field variation law of porcelain insulators under suspended sand and dust weather, a simulation model of xp-70 ceramic suspension insulator was established on the basis of electrostatic field model of finite element method, and the potential and electric field distribution law of porcelain insulators in various suspended sand and dust environments was summarized on the basis of finite element software calculation. The results show that the electrically neutral sand particles in the air can cause small distortion of the surface potential and electric field of porcelain insulator. When the sand and dust around the insulator are all positively charged, the surface potential will increase, and the surface electric field will decrease near the high voltage end and will increase near the low voltage end. When the sand and dust around the insulator are all negatively charged, the surface potential will decrease as a whole, the surface electric field will increase near the high voltage side of insulator string and will decrease near the low voltage side, and its distortion amplitude is proportional to the absolute value of dust particle size, concentration, and charge-mass ratio. When the insulator is in a mixed sand and dust environment of half charged and half electro-neutral, its surface potential and electric field will be distorted, and its distortion amplitude is less than that when the entire sand and dust are charged, and greater than that of the insulator alone in the sand and dust environment. When the insulator is in a "positive and negative" sand and dust environment, the distortion amplitude of surface potential and electric field is similar to the distortion amplitude in the electro-neutral sand and dust environment.
External force is the significant factor affecting the buffer layer ablation faults development of high voltage cables. The actual cable laying conditions and cable core gravity will lead to inhomogeneous force on the buffer layers. However, the influence of inhomogeneous force on the development process of buffer layer ablation faults is still unclear. In this paper, a simulating ablation experiment platform of buffer layers under inhomogeneous force was built. The influence of local inhomogeneous force on the buffer layer ablation development process was studied under dry and wet conditions. Then combining with the variation of buffer layer local volume conductivity, micromorphology and the components of ablation products, the affecting mechanisms of inhomogeneous force on the fault development were analyzed. The results show that in the dry condition, the current density of buffer layer decreases gradually with the ablation time, and the decreasing rate is higher in the force concentration region. While in the wet condition, the current density of buffer layer surges dramatically in the initial ablation stage, and then drops rapidly, exhibiting the characteristic of a current density peak. In the local force concentration region, the peak value of current density is larger, and the current density variation rate inner the peak is faster. It is analyzed that the local force concentration could increase the effective contact area between the buffer layer semi-conductive fibers, leading to the rising of current density and aggravating of ablation process.
Polymer film capacitors are widely used in many fields, such as high-pulse power technology, aerospace technology, and new energy vehicles due to their ultra-high charge and discharge efficiency. Polymer dielectrics used in energy storage applications often require high energy density and energy storage efficiency, and biaxial tensile polypropylene (BOPP) films, which are widely used in commercial thin-film capacitors, cannot meet the increasing demand for energy storage. Among many polymer dielectric materials, polymethyl methacrylate (PMMA) has attracted extensive attention due to its high breakdown strength, low dielectric loss, and easy processing. In this paper, the research progress of PMMA basic characteristic and composite dielectric materials in the field of energy storage was reviewed. The methods to improve the energy density and energy storage efficiency of polymer dielectric materials through chemical modification and physical modification were summarized, and the future development direction of dielectric materials was prospected.
Composite cross arm has wide application prospect because of its good insulation performance, light weight, and saving transmission corridor. However, the research on the production design, test acceptance, construction operation and maintenance, standards and specifications of composite cross arms, especially for 500 kV and above of composite cross arms is still blank at home and abroad. The electric field distribution characteristics of high-voltage composite cross arm during operation is a problem that must be solved in the process of design and acceptance of composite cross arm. In view of the above situation, an electric field distribution and potential calculation model of 500 kV composite cross arm was established in this paper. The 500 kV composite cross arm and its connected tower were simulated and analyzed by the finite element analysis software. In addition, for the convenience and operability of subsequent ageing and insulation experiments, a 500 kV composite insulation cross arm scaling model was established and its test voltage was determined. The results show that the maximum field strength on the surface of composite insulated cross arm occurs at the high voltage of cross arm, and the electric field strength is 3.82×105 V/m. The maximum electric field strength on the surface of the cable-stayed insulator is 86.38% of maximum electric field strength of the strut cross arm, and the maximum electric field strength is 3.3×105 V/m. The test voltage, which make the maximum surface electric field strength reach expected electric field strength, is determied as 60 kV when the scale model is reduced according to 1∶5, which provides theoretical basis for the initial test of composite cross arm.
Insulating materials are more prone to early failure under pulsed voltage, which seriously threatens the stability of power electronic devices and equipment. In order to explore the microscopic mechanism of insulation failure under pulsed voltage, the effect of space charge density in polyimide on the charge-excited molecular vibration at the pulse edge was explored in this paper, and the molecular vibration mechanism at the pulse voltage edge was expounded from the perspective of frequency domain. The results show that there is a large amount of heteropolar space charges accumulated inside the polyimide sample under DC voltage, which leads to the reversal of polarity of the molecular vibration waveform. In the frequency spectrum of pulse voltage rising edge, the voltage component in the frequency band of 5×106-1×107 Hz plays a major role in the molecular vibration. The charge-excited molecular vibration will expand the insulation defects and eventually lead to insulation failure.
The thermal effect in the long-term operation of pumped storage generator sets will cause adverse effect on the main insulation performance of stator bars. Taking the VPI stator bar of an 18 kV pumped storage generator as the research object, we prepared samples and designed thermal ageing scheme. By means of dielectric property test, conductivity test, and breakdown characteristic test, the electrical properties of stator insulation under different ageing temperatures and different ageing cycles were explored. The test results show that there is obvious and complete loss peak in the bending section of stator bar. During the thermal ageing process, the dielectric constant frequency spectrum of insulating material shows an increasing trend with the increase of ageing period, and the dielectric constant of the bending section shows a stepwise decreasing trend with the increase of frequency. As thermal ageing progresses, the conductivity of samples increases gradually, and the absorption ratio and polarization index both show a decreasing trend. The breakdown strength of the straight section sample and the bending section sample continues to decrease, and the breakdown strength of the bending section sample decreases more significantly.
EVA resin insulating blankets are widely used in distribution network non-stop operations, and they often suffer from thermal melting and mechanical damage under high temperature and high load conditions, which will lead to insulation failure. In order to analyze the effect of high temperature on the mechanical properties of EVA insulating blankets, EVA insulating blankets were conducted tensile test, X-ray diffraction analysis (XRD), and dynamic mechanical thermal analysis (DMA) analysis at different temperatures, and their mechanical properties and aggregated structure changes at high temperatures were characterized by parameters such as elongation at break, tensile strength, and storage modulus. The results show that with the increase of temperature, the crystal type in the structure of EVA insulating blanket remains unchanged, and the crystallinity tends to increase, the grain size in the main crystallization area decreases at first and then increases, and the corresponding grain spacing gradually increases, which results in the elongation at break of EVA insulating blanket showing the trend of increasing at first and then decreasing. However, the tensile strength of EVA insulating blanket tends to decrease. Under high temperature, the storage modulus of EVA insulating blanket shows a decreasing trend, which indicates that the EVA insulating blanket is less resilient and less rigid under high temperature, and 40℃ is an appropriate operating temperature for the EVA insulating blanket.