收藏切换
Influence of fluorescent fibers layout methods on detection of partial discharge signals
收藏切换
PDF
Shaorui QIN1, Shuo QIN2, Yanguo KE3, Bingbing LI1, Chao PAN3, 4, Jinfei QIN1, Cheng PAN2
Insulating Materials | 2023, 56(8) : 64 - 72
Less
收藏切换
Insulating Materials | 2023, 56(8): 64-72
Insulation Technology
Influence of fluorescent fibers layout methods on detection of partial discharge signals
Full
Shaorui QIN1, Shuo QIN2, Yanguo KE3, Bingbing LI1, Chao PAN3, 4, Jinfei QIN1, Cheng PAN2
Affiliations
  • 1State Grid Anhui Electric Power Corporation Research Institute, Hefei 230601, China
  • 2School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
  • 3State Grid Anhui Electric Power Corporation, Hefei 230022, China
  • 4School of Electrical Engineering, Xi′an Jiaotong University, Xi′an 710049, China
Published: 2023-08-20 doi: 10.16790/j.cnki.1009-9239.im.2023.08.010
Outline
收藏切换

Partial discharge optical measurement method has strong anti-interference ability and high sensitivity, becoming one of the most important and effective methods to evaluate the insulation condition of electrical equipment, whose signal detection capability is closely related to the layout way of fluorescent fiber sensor. An experimental platform for fluorescent fiber PD detection was built in this paper. The influence of the relative distance between sensor and insulation defect on the PD detection effect was studied in linear layout and Archimedean layout, and then compared with the commonly used UHF method. The results show that the sensitivity of the Archimedes layout is better than the linear layout. When the distance between fluorescent fiber and PD defect is less than 45 cm, the two layout methods of fluorescent fiber sensors have higher detection sensitivity than that of the UHF sensors. For the linear layout, increasing horizontal distance has a more detrimental effect on PD detection than increasing vertical distance. For the Archimedean layout, the lateral offset of fluorescent fiber has a greater effect on the detection PD than the horizontal distance. Finally, according to the characteristics of the two layouts and the location of switchgear where PD is likely to occur, recommendations for placing fluorescent fibers in the switchgear were given.

fluorescent fiber  /  layout method  /  optical signal  /  partial discharge
Shaorui QIN, Shuo QIN, Yanguo KE, Bingbing LI, Chao PAN, Jinfei QIN, Cheng PAN. Influence of fluorescent fibers layout methods on detection of partial discharge signals[J]. Insulating Materials, 2023 , 56 (8) : 64 -72 . DOI: 10.16790/j.cnki.1009-9239.im.2023.08.010
Year 2023 volume 56 Issue 8
PDF
121
56
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2023.08.010
  • Receive Date:2022-10-24
  • Online Date:2025-11-24
  • Published:2023-08-20
Article Data
Affiliations
History
  • Received:2022-10-24
  • Revised:2022-12-05
Funding
Affiliations
    1State Grid Anhui Electric Power Corporation Research Institute, Hefei 230601, China
    2School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
    3State Grid Anhui Electric Power Corporation, Hefei 230022, China
    4School of Electrical Engineering, Xi′an Jiaotong University, Xi′an 710049, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2023.08.010
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT