• Suke Jin , Xuan Huang , Dongliang Shao , Meng Yu , Junlong Xie , Jianye Chen
    Journal of Refrigeration. 2025, 46(5): 32 -38.

    In this study, an experimental platform for cryo-adsorption and hydrogen storage systems was constructed to investigate the cryo-adsorption hydrogen storage law in the system and explore the kinetic and thermodynamic properties of cryo-adsorption hydrogen storage and the hydrogen storage performance of the entire system. The experimental results demonstrated that the adsorbent material exhibited an excellent hydrogen storage capacity under liquid nitrogen temperature zone conditions, and the adsorbent material demonstrated a high hydrogen storage capacity reaching mass-weight ratio of 5.02%, equivalent to the total hydrogen storage density of 16.63 kg/m3 under a charging pressure of 5 MPa and final storage pressure of 3.04 MPa. Through experimental research, the key factors affecting the hydrogen storage performance were revealed. These factors include the microstructural properties of the adsorbent materials, thermodynamic effects during the adsorption process, and experimental operating conditions. This experimental basis provides a foundation for optimizing the performance of hydrogen storage systems.

  • Jianing He , Jie Lu , Yang Zhao
    Journal of Refrigeration. 2025, 46(5): 115 -123.

    The high redundancy of the measured data from heating, ventilation, and air conditioning (HVAC) systems significantly reduces the computational efficiency of model calibration. To address this challenge, a model calibration method based on mining feature operating conditions and a priori probability guidance was introduced in this study. Correlation analysis was conducted on the operational data for mining feature operating conditions. Feature variables related to HVAC system operation were selected, and a grid sampling technique based on these characteristic variables was employed to obtain representative operating conditions, enhancing the efficiency of the model calculations. Additionally, a prior probability model was established for the parameters to be calibrated during the model calibration process. A priori interval estimation was then performed, and the objective function was improved based on the prior probability to guide the model towards faster convergence. The proposed method was validated using a one-month operational dataset from a cooling plant in an industrial building located in Wuhan, China. The results indicated that the proposed method achieved significant improvements in performance metrics. Specifically, mean absolute percentage error (MAPE) and cross-validated root mean square error (CV-RMSE) were reduced by 16.0% and 12.0%, respectively, compared to the K-means clustering-based method, and by 20.9% and 15.2%, respectively, compared to the baseline data-based method. Furthermore, the normalized mean bias error (NMBE) was closer to zero, and the coefficient of determination (R2) increased by 4.7% and 8.5%, respectively, compared to the two aforementioned methods. Additionally, our method enhanced the computational efficiency by approximately 39.3%. This method provides technical guidance and data support for achieving an efficient and accurate modeling of HVAC systems.

  • Jiajun Pan , Huafu Zhang , Zhentao Zhang , Junling Yang , Xiangwen Meng , Hongwei Wu
    Journal of Refrigeration. 2025, 46(5): 58 -68.

    Mechanical vapor compression (MVC) systems are energy-saving technologies that recover and reuse low-temperature waste heat resources, achieving energy conservation and carbon reduction. As the core equipment in MVC systems, the compressor directly affects the overall performance of the system. This article primarily reviews the thermodynamic and structural performance of vapor compressors, proposes relevant enhancement suggestions and improvement ideas, and provides a reference and assistance for the subsequent optimization of vapor compressor performance.

  • Fujun Ju , Lihao Hou , Qinglei Liu , Haoran Wang , Chengjie Xiao , Xiaowei Fan
    Journal of Refrigeration. 2025, 46(5): 69 -76.

    R1270 and R290 are alternative refrigerants with great potential. In this study, the influence of the refrigerant charge on the performance of the heat-pump water heater with R1270 and R290, the temperature distribution of the heat transfer fluids in the condenser, and the feasibility of replacing R22 with natural refrigerants were investigated. The results indicate that the refrigerant charge has a considerable influence on the cycle performance and the temperature distribution of the heat-transfer fluids in both systems. At the same optimal charge (0.90 kg), the R1270 and R290 systems achieved a maximum coefficient of performance (COP) of 4.443 and 4.317, respectively. At different refrigerant charges, two heat transfer pinch points and two maximum heat transfer temperature differences occurred in the condensers of both systems, and the locations of the first pinch point and the second maximum temperature difference point showed similar migrations with changes in refrigerant charge. Compared with the R22 system, both the R1270 and R290 systems, at optimal charge, achieved significantly better COP and discharge temperatures, exhibited relatively equivalent discharge pressures, and their heating capacities increased by 7.05% and decreased by 10.65%, respectively. Hence, R1270 can be preferred over R290 for replacing R22 in a heat-pump water heater.

  • Chaohui Zhou , Yuce Liu , Yue Hu , Jicheng Zhang , Zhiyong Tian , Yu Ruan , Huiheng Luo , Yongqiang Luo , Guozhi Xu
    Journal of Refrigeration. 2025, 46(5): 133 -141.

    Seasonal thermal energy storage (STES) can effectively mitigate the supply and demand imbalance of solar energy between winter and summer. Large-scale water pit thermal storage systems require efficient and accurate computational simulations to avoid investment waste. This study proposes a simplified numerical analysis method and establishes a cylindrical underground pit with a total volume of 11 304 m3 to describe the operation of a STES system. The model establishes a one-dimensional heat transfer model for the water body and a two-dimensional heat transfer model for the soil, separately solving for the water and the soil temperature field. The two models are connected through the temperature boundary at the pool wall to simulate the entire system. To comprehensively verify the accuracy of the numerical simulation model, validation was conducted under standby, charging, and discharging modes. The results indicate that the developed model has good accuracy and reliability. Under the standby mode, the temperature error of the five water layers in the sandbox test is less than 10%, with the highest accuracy in the middle and lower-middle water layers, with an average absolute error of 1.75% and 1.24%, respectively. Under the charging mode, the average relative error is 1.57%, and the average temperature error is 0.44 ℃. Under the discharging mode, the average relative error is 0.46%, and the average temperature error is 0.24 ℃.

  • Yihuai Hua , Qiuying Li , Hao Cheng , Haochuan Bai , Hanwei Zhang , Wenrui Liu , Kai Wang , Limin Qiu
    Journal of Refrigeration. 2025, 46(5): 12 -23.

    Ortho-para hydrogen conversion in the hydrogen liquefaction process is significant for the long-term storage and long-distance transportation of liquid hydrogen. This paper outlines the differences in the properties of orthohydrogen and parahydrogen, reviews the research progress on the physical mechanisms and reaction kinetic models of the ortho-para hydrogen catalytic conversion process, and summarizes the performance of common catalysts. Finally, three mainstream schemes for ortho-para hydrogen conversion are compared. Research on the internal physical mechanisms and reaction kinetic models explores the conversion process from microscopic and macroscopic perspectives, respectively. Owing to the lack of experimental data, scholars have not yet formed a unified explanation for the surface characteristics of catalysts, which must be quantitatively validated. Furthermore, although nickel-based catalysts have higher catalytic efficiency, iron hydroxides and oxide catalysts are the main catalyst choices for ortho-para hydrogen conversion, considering the preparation, activation, and deactivation of catalysts and the characteristics of the liquefier. Among the three mainstream ortho-para hydrogen conversion schemes, the hydrogen liquefaction process with continuous conversion has the lowest energy consumption and is the future direction. Relevant research in China is still in its early stages and has great potential for development. This study provides theoretical guidance for the design and construction of ortho-para hydrogen catalytic conversion test benches.

  • Jian Sun , Fan Ye , Chao Zhong , Jie Li
    Journal of Refrigeration. 2025, 46(5): 166 -174.

    With the development of computer technology and the application of artificial intelligence, electronic chips are becoming increasingly miniaturized and integrated, leading to a rapid increase in their volumetric heating power, thus affecting their normal operation. To address this problem, a heat sink with an array of finned porous microjets was designed, and HFE-7100, which has good thermal stability and electrical insulation, was selected as the cooling medium. Through a combination of numerical simulations and experimental research, the influence of factors such as the longitudinal aspect ratio of the slotted fins, inlet subcooling, inlet volumetric flow rate, and jet Reynolds number on the heat transfer process of microjet boiling was investigated. The results showed that the optimized structure with an aspect ratio of 0.5 met the requirements of chip cooling and had a better cooling effect. In the single-phase convection heat transfer stage, under the same working condition, the inlet subcooling degree had little effect on heat transfer, and increasing the volume flow rate or jet Reynolds number could strengthen the convection heat transfer, and the maximum heat transfer coefficient could reach 15 724.40 W/(m2·K). However, in the jet boiling stage, the heat flux corresponding to the onset of nucleate boiling (ONB), and it decreased with a decrease in the inlet subcooling degree. Increasing the inlet volume flow rate or jet Reynolds number inhibited the occurrence of boiling, thus weakening the heat transfer. However, compared with the single-phase convective heat transfer stage, the heat transfer coefficient increased by 20.6%.

  • Bowen Zhang , Zhiqiang Zhang , Hongxia Zhao , Gongming Xin , Yiguang Cheng , Guangpeng Li
    Journal of Refrigeration. 2025, 46(5): 86 -95.

    Quantitative research on the industrial application of direct cooling ice makers is limited, resulting in a lack of clarity in control mechanisms and inadequate heat transfer capability and uniformity in ice making. A mathematical model focusing on the refrigerant side of the ice mold evaporator was established, and a MATLAB simulation model was used to analyze the changes in heat transfer and flow parameters in the flow direction throughout the ice-making process, with comparisons drawn between the experimental data and the simulation results. The heat transfer rate before water icing was approximately 30% higher than that after water icing, and the refrigerant flow rates were significantly different. The heat flux in the superheat region decreased by 40.9% compared to that in the two-phase region, and reducing the superheat section can significantly enhance heat transfer and improve temperature uniformity. The thermal resistances of the water and ice sides accounted for 93.4% and 91.7% of the total resistance, respectively. Thus, the heat transfer of the water side or ice side should first be improved to optimize heat transfer. The simulation model can predict the change in the flow rate and simulate the superheat section, which provides a theoretical basis and practical guidance for the design and operation control of an ice-making machine and helps to improve the product performance and accelerate the ice-making process.

  • Weijie Lin , Jiwen Cen , Abdullah Hassan , Fangming Jiang
    Journal of Refrigeration. 2025, 46(5): 105 -114.

    The combination of a super-long gravity heat pipe and a heat pump system for harvesting deep geothermal heat has the advantages of low cost, high efficiency, and no groundwater contamination. Direct heat exchange between the evaporator of the heat pump system and the condenser of the gravity heat pipe can simplify the heat exchange process and improve the heating efficiency of the system. Therefore, a U-shaped evaporator-condenser was developed, and its heat transfer performance was studied by building an experimental platform combining a heat pump and a heat pipe. Notably, the heat transfer coefficient of the U-shaped evaporator-condenser reached 2 037.92 W/(m2·℃) when the working fluid on the heat pump side passed through the tube. Based on the homogeneous flow model, a one-dimensional steady-state evaporator-condenser heat transfer model was established by integrating the mass, energy, and momentum conservation equations with empirical formulas for condensation outside the tube and boiling heat transfer inside the tube. Using Python, the simulation results were compared with experimental data. Notably, the average deviation of the heat transfer in the evaporator-condenser was 18.91%, confirming the accuracy of the model and providing a theoretical calculation method for designing an efficient evaporator-condenser.

  • Qinghua Chen , Baixue Peng , Yu Lu , Jiadong Ji
    Journal of Refrigeration. 2025, 46(5): 96 -104.

    Frosting is one main adverse factor hindering the application of finned tube evaporators in refrigeration systems. To accurately predict the growth characteristics of the frost layer, its growth behavior on the surface of a three-dimensional finned tube under forced convection conditions was numerically simulated based on the coupled VOF (volume of fluid) multiphase flow and phase change mass transfer rate model method. The maximum difference between the simulated frost layer thickness and the experimental results was within 15%. The estimated value of the frost layer density was within a confidence interval of up to 90%; this is in good agreement. By building a visualization experimental platform for frosting on the surface of the finned tube of the evaporator, the influences of ambient temperature, relative humidity, and frontal wind speed on frost growth characteristics under single-factor changes were analyzed. The results showed that the thickness of the frost layer gradually decreased from front to back in the direction of the airflow. The lower the air temperature, the greater the wind speed, the higher the relative humidity, the larger the thickness of the frost layer, the more frost, and the larger the thermal resistance of the frost layer. The thickness of the frost layer reached its highest value of 2.344 mm at 85% relative humidity. According to the Morris sensitivity analysis, the relative humidity had the greatest influence on the frost layer thermal resistance, and the sensitivity coefficient reached 2.41. The correlation of the frost layer thermal resistance with different environmental parameters was obtained using the least squares regression method.

More