Home Latest Articles
Latest Articles
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 10-20.
    Compared with the individual combustion process, the mixed combustion of methane and hydrogen has the advantages of reducing carbon emissions and improving energy flexibility. A molecular simulation method was used to study the co-combustion characteristics of methane and hydrogen in reaction systems of air and oxygen-enriched atmospheres. The results show that the consumption rate of CH4 under a high volume fraction of CO2 is smaller than that in an air atmosphere, because CO2 is chemically inert at low temperatures. Whereas under high-temperature conditions, the rapid oxidizing property of CO2 accelerates the consumption of methane and hydrogen. In both air and oxygen-enriched atmospheres, when the hydrogen blending ratio is 0.5, hydrogen promotes the combustion of methane. The elevation of ambient pressure can accelerate the combustion of methane and hydrogen, but under oxygen-enriched conditions, the CH4 consumption rate is lower than in the air atmosphere, with the main reason being that the increase in pressure strengthens the intermolecular forces of CO2, causing it to exhibit chemical inertness. With the increase of O2 volume fraction, the combustion rates of CH4 and H2 increase in both atmospheres, but the consumption rate of CH4 in the air atmosphere is greater than that in the oxygen-enriched atmosphere. Temperature, hydrogen blending ratio, pressure, and equivalence ratio have a relatively small effect on the overall reaction pathway of methane-hydrogen blended combustion, but the reaction atmosphere affects the gas combustion rate by influencing the initial reaction time of certain key reactions.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 1-9.
    Soot is a crucial radiative product in combustion processes, exerting a significant influence on energy efficiency and pollutant emissions. However, the complexity of the soot formation process has led most existing models to rely on complex chemical reaction mechanisms, resulting in high computational costs and limiting corresponding widespread adoption in engineering applications. To address this issue, a laminar smoke point model and a full-spectrum k-distribution radiation model were embedded using user-defined functions in ANSYS-Fluent software to efficiently simulate soot formation and radiation characteristics in ethylene laminar diffusion flames. The soot concentration fields and spectral radiative intensities under different blending ratios were measured by using a complementary metal oxide semiconductor (CMOS) camera and a Fourier-transform infrared spectrometer, so as to validate the effectiveness of the overall model. Results demonstrate that, through a single-step chemical reaction and an additional species transport equation, the proposed model can accurately capture the morphological characteristics of soot distribution within the flame. The radial average volume fraction distributions of soot at different heights exhibit good agreement with experimental data. Meanwhile, the simulated spectral radiative intensities at different heights match well with the measured values, validating the efficiency and accuracy of the overall model. This provides a reliable tool for engineering calculations of soot formation and radiation characteristics in flames.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 18-26,36.
    The tips of the first-stage rotor blades in heavy-duty gas turbines often suffer damage such as ablation and cracking due to excessive thermal load concentration and large temperature gradients in these regions. Taking the first-stage rotor blades of a heavy-duty gas turbine as the research object, an initial layout scheme combining grooved tips with film holes was established based on tip leakage flow, heat transfer characteristics and temperature distribution. Subsequently, the film hole positions were optimized using a Kriging surrogate model combined with genetic algorithm, and the optimized scheme was validated through thermo-mechanical coupling analysis. Results show that the optimized scheme reduces the maximum tip temperature from 1 220.67 K to 1 167.95 K with a decrease exceeding 50 K, while effectively improving the temperature distribution at the pressure-side shoulder. The optimized scheme prevents cold gas waste and stress concentration. This study provides theoretical foundations and engineering references for optimizing cooling structures at the tips of rotor blades in heavy-duty gas turbines.
  • WANG Long, HE Yingjing, ZHANG Hongze, LI Yang, TIAN Xueqin, CHEN Qingyue
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 161-172.
    Wind and photovoltaic power generation, as mature renewable technologies, have been widely applied in power systems. However, their intermittency and uncertainty severely limit long-term supply reliability. To improve the economic performance of multi-energy power systems during the planning stage and enhance renewable energy accommodation, an optimal capacity configuration model for wind-PV-pumped storage considering construction sequencing and a flexibility retrofit scheme for thermal power units were proposed. First, an optimal capacity configuration model for wind-PV-pumped storage considering construction sequencing and a flexibility retrofit model for thermal power units were established, and the objective function as well as various constraints of the optimization model were formulated. The nonlinear parts were linearized using special ordered set of type 2 (SOS2) and McCormick convex envelope relaxation, transforming the original nonlinear problem into a mixed-integer linear programming problem. Based on historical wind, solar, and load data from a multi- energy power system, typical daily scenarios were generated using density peak clustering. Results verify the rationality of the proposed model and retrofit scheme.
  • Journal of Chinese Society of Power Engineering. 2026, 46(1): 1-9.
    In order to study the dynamic characteristics of the cooling wall in the ultra-supercritical boiler, a dynamic simulation model of the cooling wall in a 1 100 MW ultra-supercritical boiler was established under the condition that the heat load distribution along the height of the cooling wall was uneven. The distribution of the working fluid temperature and the metal wall temperature along the height of the cooling wall were simulated. The dynamic response characteristics of the main thermodynamic parameters of the working fluid and the metal wall temperature were analyzed when the flow rate at the cooling wall inlet was step-disturbed. Results show that under the design condition of 50%THA(turbine heat acceptance), the dryness of the working fluid at the height of 37.5 m in the cooling wall reaches 0.994, and the inner wall temperature reaches up to 466.1 ℃. At 30%THA, the peak temperature of the inner wall at 42.0 m reaches 375.3 ℃. The larger the flow steps, the longer the dynamic response time is, the heat transfer deterioration is aggravated, and the wall temperature in the evaporation and drying region increases. At 50%THA, after the flow step is reduced by 5.0%, the wall temperature at 36.0 m reaches 547.9 ℃ in this process, and no overheating occurs. After the flow stability, compared with the design flow, when the flow step is reduced by 2.5% and 5.0%, the inner wall temperature at 50%THA and 34.5 m will be increased by 5.6 and 17.2 K respectively.
  • Journal of Chinese Society of Power Engineering. 2026, 46(1): 10-18.
    To investigate the effect of biomass co-firing on the lowest steady combustion load of the boiler, a 1 000 MW ultra-supercritical swirl-opposed boiler was taken as the research object. The combustion conditions of pure coal and the addition of cotton stalk(CS) with a co-firing ratio of 10% were simulated under different loads in the boiler. The temperature distribution and oxygen concentration distribution in the furnace under different loads were analyzed, and the evolution of the minimum stable combustion load of the boiler after co-firing biomass was explored. Results show that compared with pure coal conditions, the area with the temperature above 1 400 K of the central section of the burner increases after co-firing cotton stalks, the ignition distance is shortened by 0.24%-3.45%, the oxygen concentration at the furnace outlet increases by 0.22%-0.24%, and the combustion stability is greatly enhanced. The lowest steady combustion load of the designed coal is 40%, and the lowest steady combustion load of the boiler mixed with CS can be reduced to 30%. Therefore, biomass-mixed combustion can effectively enhance the steady combustion performance and decrease the lowest steady combustion load of the swirl-opposed boiler, and thus the peaking capability of the boiler can be promoted.
  • Journal of Chinese Society of Power Engineering. 2026, 46(1): 19-31.
    To address the technical difficulties of slow load response in circulating fluidized bed (CFB) power units due to the presence of large amounts of inert bed material on the fuel side of the boiler, a CFB power unit primarily fueled by coal gangue was focused on. A dynamic simulation model of the power unit's thermal system was established and validated, obtaining performance of key thermodynamic parameters such as output power, main steam temperature, main steam pressure, bed temperature, boiler evaporation rate and cycle efficiency during the load ramp-up process. To improve the power unit's load ramp-up capability, an optimization scheme involving dynamic co-firing of pulverized coal in the upper part of the CFB furnace was proposed to mitigate the inertial effects of coal gangue combustion. Results show that at the load ramp-up rate of 3%/min, the optimization scheme reduces the maximum deviations of output power, main steam pressure, main steam temperature, reheat steam temperature and bed temperature to 1.31%, 0.81%, 2.3 K, 3.5 K and 27.8 K respectively, all within the specified range of the DL/T 657—2015 Code for Acceptance Test of Modulating Control System in Fossil Fuel Power Plant standard. With the optimization scheme, the maximum allowable load ramp-up rate of the CFB power unit increases from 2%/min to 3%/min, while slightly improving the power unit's thermal economy.
  • Journal of Chinese Society of Power Engineering. 2026, 46(1): 32-41,50.
    Establishing an accurate model of the pulverized-coal preparation system and analyzing its operational characteristics are the key theoretical foundations for optimizing the system operational control. By incorporating the coupling relationship between the internal coal inventory of the coal mill and its operational parameters, and considering the impact of pulverized coal fineness on the output capacity of the coal pulverizing system, a gray box model of pulverized-coal preparation system with roller-type medium speed coal mills, encompassing key equipment such as coal mills, primary air fans, and coal conveying pipelines, was constructed. Based on this model, the steady-state operational characteristics of the pulverized-coal preparation system under single-parameter and fixed air-to-coal ratio conditions, as well as its dynamic operational characteristics during the startup process, were analyzed. Results indicate that when the coal feed rate (mass flow rate) increases from 12 kg/s to 26 kg/s, the specific energy consumption for coal grinding decreases from 10.26 kW·h/t to 7.14 kW·h/t, representing a reduction of 30.4%. Under a fixed air-coal ratio, the primary air temperature and the mass fraction of moisture in raw coal are identified as the key factors determining the outlet temperature of pulverized coal. When the air-coal ratio is 1.6 and the primary air temperature rises from 260 ℃ to 300 ℃, the outlet air-coal mixture temperature increases by 19.03%. During the load-increasing process, the output capacity of the coal pulverizing system is delayed by 102 s.
  • Journal of Chinese Society of Power Engineering. 2026, 46(1): 42-50.
    To address the issue of unclear vibration transmission paths in auxiliary steam turbine-generator units, taking a high-speed auxiliary steam turbine-generator unit as the research object, a complete rotor-bearing-stator model of the unit was established, and a vibration transmission model was constructed based on operational transfer path analysis (OTPA). After which, the vibration transmission characteristics of the unit were analyzed. First of all, the finite element method was applied to obtain the frequency response function of each transmission path of the unit. Taking into account the excitation sources such as rotor imbalance, pulsating vapor force and unbalanced magnetic tension, the singular value decomposition technique was adopted to reduce the noise and synthesize the input signals at the bearing seats, the transfer function matrix of the relationship between the inputs and outputs of various paths was constructed, and the vibration contribution of the different paths to the stator shell was analyze to clarify the main vibration transmission paths. Results show that the main vibration paths of the stator shell vibration at each measurement point originate from the two bearing housings of the auxiliary steam turbine, especially the generator-side bearing housing has the largest vibration contribution. The stator shell vibration can be effectively reduced by optimizing the adjustment of the structural intrinsic characteristics of the bearing housings and the phase difference of the rotor imbalance force, with the maximum amplitude being reduced from 364 μm to 51 μm. The research results can provide a reference for tracing the vibration of auxiliary steam turbine-generator units and optimizing the diagnosis of faults.
  • Journal of Chinese Society of Power Engineering. 2026, 46(1): 51-58.
    In the calculation of a regional film cooling effectiveness covered by arrayed discrete holes, conventional computational fluid dynamics (CFD) simulations are confronted with the challenges of complex grid modeling and high computation consumption. A parameterized kernel function was proposed to describe the distribution characteristics of a single fan-shaped hole and then to predict the film cooling efficiency. Integrating data-driven machine learning technique with the Sellers film cooling efficiency superposition method, the efficient prediction of cooling efficiency distribution in the coverage area of group holes was realized. Based on the parametric "Kernel" model, the cooling effectiveness distribution for both single and triple in-line rows of 7-7-7 fan-shaped holes were successfully replicated. Furthermore, In the given region, the layout of in-line group holes with the highest average cooling efficiency in the region was obtained with integer programming method. Results show that the parametric "Kernel" model can accurately reflect the distribution characteristics of cooling efficiency in the film hole coverage area, overcoming the limitation of traditional correlation equations that only predict spanwise average cooling efficiency, and significantly reduce the number of samples required for machine learning, which can be applied to the prediction of film cooling efficiency under different working conditions.