• Journal of Chinese Society of Power Engineering. 2026, 46(10): 207-216.
    To achieve the thermal-electric decoupling, a method of integrating a combined heat and power (CHP) unit with compressed air energy storage (CAES) was proposed. A thermodynamic model of a 300 MW CHP unit was developed based on Ebsilon software to analyze the variations in the unit's heat-power feasible region, energy utilization efficiency, and exergy efficiency. Additionally, a particle swarm optimization (PSO) algorithm based on position constraints was adopted to optimize the system's operation strategy with the objective of minimizing overall coal consumption. Results show that coupling with CAES can significantly expand the heat-power feasible region and enhance the deep peak shaving capability of the unit, providing a maximum increase of 35.0 MW in deep peak shaving power. When the boiler output and the power of the CAES module are fixed, the lower the heating load of the unit, the more significant the change in its energy utilization rate. Both the energy utilization efficiency and exergy efficiency of the unit are negatively correlated with charging power and positively correlated with discharging power. Within a typical daily cycle, the adjustment of charging and discharging power can increase the unit's energy utilization efficiency by up to 2.54% and the exergy efficiency by 1.41%. Furthermore, the unit can save 52.5 t/d of standard coal and reduce CO2 emissions by 136.5 t/d.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 146-153,216.
    In transmission corridor inspection, insulator targets are generally small and exhibit significant scale variations, which can easily lead to false detections and missed detections of defects. To address these problems, an improved YOLOv8-dynamic enhanced window (DEW) based insulator defect detection algorithm was proposed. Firstly, a YOLOv8n detection network was constructed. To enhance the adaptive spatial aggregation capability of model for insulator targets with different poses and scales, the third-generation deformable convolution (DCNV3) was introduced. Partial original C2f modules and standard convolution modules in the backbone network were respectively replaced with C2f_DCNV3 and DCNV3_YOLO modules. Secondly, efficient channel attention (ECA) was introduced to enhance the recognition capability of model for target defect features. Finally, wise intersection over union loss (WIOU) was adopted to replace complete intersection over union loss (CIOU), so as to reduce the bounding box regression loss and improve the localization quality of prediction boxes. Experimental results show that the model file size, parameter quantity and computational complexity of the improved model are all slightly reduced, the number of floating-point operations is decreased by 1.3×109, and the detection speed reaches 26 frames/s. For insulator defect detection, the η mAP50 of reaches 98.3%, and the η mAP50:95 reaches 86.6%. Its overall performance is superior to other mainstream object detection algorithms.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 52-61,83.
    To improve thermal management performance of proton exchange membrane fuel cells (PEMFCs) in underwater power platforms and to address the slow temperature control response caused by strong coupling and nonlinearity, a dual-actuator cooperative thermal management system based on fuzzy proportional- integral-derivative (PID) control was designed. An electro-thermal coupled mathematical model of the PEMFC was established, and a system simulation platform comprising the stack, water pump, and radiator was constructed. Results show that under dynamic current conditions, compared with conventional PID control, the fuzzy PID controller achieves faster and more stable stack temperature regulation by adjusting the water pump flow rate and radiator airflow in real time. The fuzzy PID reduces the temperature stabilization time by 323.1 s, lowers overshoot, improves efficiency, and maintains temperature control error within ±0.05 K. The system significantly enhances the robustness of PEMFCs under complex operating conditions.
  • HAN Xu, SHI Haibo
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 27-36.
    The effects of CO2 mass fraction, cascade inlet temperature, and outlet back pressure on the condensing flow characteristics and shock wave development of a mixed-working-fluid transonic cascade were investigated. 17 sets response surface design based on a three-factor, three-level approach was constructed to evaluate the influence of each factor on the integrated entropy production rate over the cascade plane. A quadratic regression function was then developed based on the response surface results. Minimization of the entropy production rate was performed under prescribed parameter constraints to determine the optimal parameter combination. Results show that when the CO2 mass fraction increases from 13.45% to 23.45%, the trailing-edge oblique shock strengthens, and the angle between the inner and outer trailing shocks decreases from 136° to 125°. When the inlet temperature exceeds 374.3 K, the shock waves within the flow field intensify, and the nucleation zone concentrates near the blade trailing edge. Increasing the outlet back pressure substantially reduces shock intensity in the cascade passage, shifts the inner and outer trailing shocks upward, and enlarges their included angle. The outlet back pressure plays a dominant role in entropy production, while the CO2 mass fraction and inlet temperature have weaker effects.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 124-137.
    A control strategy for hybrid energy storage-assisted thermal power units participating in primary frequency regulation was proposed to improve the frequency characteristics of a new power grid with a high proportion of new energy. Firstly, a primary frequency regulation model for thermal power-hybrid energy storage combined system considering the capacity degradation of energy-type energy storage was constructed. The frequency regulation dead zone of hybrid energy storage model was designed according to the frequency characteristics of power grid, and a local inertia compensation control strategy was proposed. On this basis, the model predictive control for primary frequency regulation of thermal power-hybrid energy storage combined system was implemented based on the prediction of load disturbances and system state variables, and rolling optimization was performed on the output regulation parameters of coal-fired units and various energy storage systems. Simulation results show that the proposed control strategy can effectively reduce the dynamic and steady-state frequency deviations of the system, decrease the output adjustment frequency of units and the charge-discharge depth of lithium batteries, and improve the power grid frequency quality. Compared with the traditional droop control, the amplitudes of the maximum dynamic frequency deviation and steady-state frequency deviation under step disturbance are reduced by 6.8% and 5.8% respectively, the root-mean-square frequency deviations under continuous disturbance and long-term disturbance are reduced by 8.2% and 7.2% respectively, and the percentages of frequency out-of-limit time are reduced by 10.5% and 16.1% respectively.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 154-160.
    To reveal the migration characteristics of key ions and heavy metals during flash evaporation concentration of desulfurization wastewater, a rotary evaporation experimental setup was employed. The variations in pH, total dissolved solids (TDS), Cl-, NH+4, Hg, and other key ions and heavy metals, as well as the characteristics of evaporated crystalline products, were investigated under different temperatures and concentration ratios. Results show that with the increasing concentration ratio, the pH of the concentrate decreases while TDS content increases at all evaporation temperatures. During evaporation and concentration, NH+4 and Hg partially migrate to the gas phase, whereas Cl- migration to the gas phase is negligible. After 10-fold concentration, Cl- and NH+4 remain predominantly enriched in the concentrate, while Hg is mainly enriched in the condensate. The crystalline products exhibit in sheet structure, with CaSO4 as the main component and minor NaCl crystals.
  • ZHENG Haoyu, ZHOU Jiahui, XU Gang, TONG Bing, WANG Haiming, XUE Xiaojun
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 84-93,195.
    To improve economic performance and grid coordination capability of wind-solar-hydrogen-methanol systems under electricity spot market environment, a collaborative optimization method for capacity configuration and operational scheduling was proposed. A mixed-integer linear programming model was established with the objective of maximizing the annual operating revenue of the system. The model was solved based on 8 760 h of wind-solar output and real-time electricity price data from the Mengxi region. Detailed capacity configuration and economic analyses were conducted, and the results were compared with those from a tiered electricity pricing scheme. Results indicate that under the spot market scenario, the system can flexibly schedule its operations in response to variations in renewable resources and electricity prices, thereby improving the utilization of renewable energy and power resources. This leads to increased annual revenue and reduced levelized cost of methanol. The proposed approach addresses the system planning problem under dual fluctuations of wind-solar output and electricity prices, providing a theoretical basis for the market-oriented operation of renewable-energy-based hydrogen production systems.
  • LIU Fei, CHEN Heng, LI Jinhang, ZHENG Hongxu, PAN Peiyuan
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 196-206.
    To address the demands for deep peak shaving and low-carbon retrofitting of coal-fired power plants, a molten salt thermal energy storage-assisted carbon capture, utilization and storage (CCUS) coal-fired power generation system was proposed. Models of the thermal energy storage system and carbon capture system were developed using EBSILON and ASPEN PLUS software, respectively, enabling full-process simulation of a 630 MW unit. The economic was evaluated to study the mechanisms of thermal storage systems in enhancing peak-shaving capabilities and the impact of CCUS systems on carbon emissions. Results show that the thermal energy storage system adopts a dual-tank molten salt configuration with a designed storage capacity of 875 MW·h, achieving a thermal efficiency of 95%. The storage tank volume is 6 730 m3, with a unit cost of 175 yuan/(kW·h). Under various operating conditions, the CO2 capture rate of the CCUS system remains consistently at 90%, with an annual emission reduction of 1.654 6 million tons. After retrofitting, the unit's peak-shaving depth decreases from 40% to 0%, while the peak-shaving capacity increases by 180.1 MW, and the levelized cost of electricity (LCOE) changes from 0.374 8 yuan/(kW·h) to 0.365 3 yuan/(kW·h). The total project investment amounts to 2.374 billion yuan. Under the carbon trading price of 98 yuan/t, the net present value reaches 573 million yuan, with a payback period of approximately 19 years. Sensitivity analysis reveals that for every 10 yuan/t increase in carbon price, the LCOE decreases by 0.002 7 yuan/(kW·h), and for every 50 yuan/(MW·h) increase in peak-shaving compensation price, the LCOE decreases by 0.004 yuan/(kW·h). This study provides a technical pathway and economic assessment framework for the synergistic development of flexibility retrofitting and low-carbon transformation in coal-fired power units.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 173-185.
    To address the increasing challenge of resource utilization of urban solid waste, a novel low-carbon supercritical water gasification (SCWG) system coupled with solid oxide fuel cell (SOFC) for combined heat and power (CHP) generation was proposed, which used coal and solid waste as co-fuels. The system employed chemical looping to reform the outlet syngas and capture carbon, while solar energy was introduced as the input to heat the gasification preheater and the calcium carbonate calciner. To further enhance waste heat recovery and carbon capture efficiency, the system was optimized by replacing the gasification system cooler with an organic Rankine cycle (ORC) for partial energy recovery, and by adopting anode fuel recirculation to improve CH4 reforming conversion. Based on these improvements, energy and exergy analyses were conducted to explore the effects of key parameters on the system performance. Results show that the improved system outperforms the original design in all performance metrics. The introduction of the ORC and fuel recirculation significantly increases power output and carbon capture. The improved system achieves high energy efficiency and carbon capture rate under design operating conditions: energy efficiency of 64.97%, power generation efficiency of 52.24%, exergy efficiency of 51.34%, and carbon capture rate of 94.34%, which are improvements of 2.03, 3.10, 3.01, and 18.15 percentage points, respectively. Increasing the gasification temperature and system water input or reducing gasification pressure all enhance hydrogen production in the gasification system. A lower coal-to-solid waste ratio improves the gasification conversion of the fuel. Higher SOFC operating temperature and pressure also improve system energy efficiency, with an optimal temperature range of 850-990 ℃. When the fuel recirculation ratio exceeds 0.75, near-zero CO2 emissions can be achieved.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 186-195.
    The Allam cycle is a power cycle fueled by natural gas using supercritical carbon dioxide as the working fluid, characterized by extremely high cycle efficiency, a near 100% carbon dioxide capture rate, and the potential for near-zero system emissions. A thermodynamic calculation model of the Allam cycle was developed, and a sensitivity analysis was conducted regarding the impacts of turbine inlet and outlet parameters, turbine cooling gas temperature, isentropic efficiency of power equipment, and the minimum cycle temperature on the system cycle efficiency. Based on the optimization results, a parameter scheme for a 100 MW class Allam cycle was proposed. The results indicate that the influence of turbine inlet pressure, inlet temperature, and outlet pressure on cycle efficiency exhibits a non-monotonic relationship. Effectively utilizing turbine exhaust waste heat and increasing the cooling gas temperature can improve the system cycle efficiency. Among the system power equipment, compared with the influence of compressor isentropic efficiency, turbine isentropic efficiency has a greater impact on the system cycle efficiency, with every 1 percentage point increase in turbine isentropic efficiency resulting in 0.32 percentage points increase in system cycle efficiency. Under the conditions of a turbine inlet pressure of 28 MPa, inlet temperature of 1 150 ℃, outlet pressure of 3.8 MPa, and a minimum cycle temperature of 24 ℃, the system cycle efficiency reaches 54.22%.
More