Home Archive
Archive
2026 Volume 46 Issue 10  Published: 2026-10-15
  • doi: 10.19805/j.cnki.jcspe.2026.250567
    For boiler state monitoring in complex environment, a single sensor often fails to provide comprehensive and accurate information. A monitoring method based on multisensor fusion was proposed, which enhanced system performance by integrating data from different types of sensors. The principles of system construction and the theories and optimization strategies of data fusion algorithms, such as Kalman filtering and KalmanNet, were analyzed. Results show that multisensor fusion significantly reduces prediction errors, with Kalman filtering reducing the mean square error of sensor predictions by 37% to 50% and KalmanNet improving accuracy by over 60%. In terms of overall model performance, KalmanNet with adaptive feedback achieves an accuracy of 93.2%. Despite its higher computational cost, KalmanNet demonstrates superior precision and robustness under complex state monitoring. The proposed multisensor fusion method not only improves state estimation accuracy and system stability but also offers significant application value for industrial safety monitoring.
  • doi: 10.19805/j.cnki.jcspe.2026.250284
    With the development of coal-fired power transformation, there is an increasing need for large-scale scheduling and other macro decision-making in the power grid. Previous reliability prediction methods for single units cannot meet the power grid's demand for reliability information of unit sets. In order to accurately and efficiently predict the reliability of coal-fired power unit sets, a reliability prediction model of unit sets based on Apriori algorithm optimized back propagation (BP) neural network input (Apriori-BP) was proposed. The Apriori algorithm measured the correlation between the influencing factors and the prediction target based on their impact, which could more accurately measure the overall correlation between the composite influencing factors and the prediction target, thereby better optimizing the model input. Apply the Apriori-BP prediction model to the actual power grid, predict the reliability of multiple different sets of units, and compare the prediction errors with the grey relational analysis (GRA)-BP model and principal components analysis (PCA)-BP model. Results indicate that the Apriori-BP model has the highest prediction accuracy, with root mean square error and mean absolute error of 0.021 4 and 0.009 7, and better generalization ability and robustness.
  • doi: 10.19805/j.cnki.jcspe.2026.250781
    The tips of the first-stage rotor blades in heavy-duty gas turbines often suffer damage such as ablation and cracking due to excessive thermal load concentration and large temperature gradients in these regions. Taking the first-stage rotor blades of a heavy-duty gas turbine as the research object, an initial layout scheme combining grooved tips with film holes was established based on tip leakage flow, heat transfer characteristics and temperature distribution. Subsequently, the film hole positions were optimized using a Kriging surrogate model combined with genetic algorithm, and the optimized scheme was validated through thermo-mechanical coupling analysis. Results show that the optimized scheme reduces the maximum tip temperature from 1 220.67 K to 1 167.95 K with a decrease exceeding 50 K, while effectively improving the temperature distribution at the pressure-side shoulder. The optimized scheme prevents cold gas waste and stress concentration. This study provides theoretical foundations and engineering references for optimizing cooling structures at the tips of rotor blades in heavy-duty gas turbines.
  • doi: 10.19805/j.cnki.jcspe.2026.250241
    The effects of CO2 mass fraction, cascade inlet temperature, and outlet back pressure on the condensing flow characteristics and shock wave development of a mixed-working-fluid transonic cascade were investigated. 17 sets response surface design based on a three-factor, three-level approach was constructed to evaluate the influence of each factor on the integrated entropy production rate over the cascade plane. A quadratic regression function was then developed based on the response surface results. Minimization of the entropy production rate was performed under prescribed parameter constraints to determine the optimal parameter combination. Results show that when the CO2 mass fraction increases from 13.45% to 23.45%, the trailing-edge oblique shock strengthens, and the angle between the inner and outer trailing shocks decreases from 136° to 125°. When the inlet temperature exceeds 374.3 K, the shock waves within the flow field intensify, and the nucleation zone concentrates near the blade trailing edge. Increasing the outlet back pressure substantially reduces shock intensity in the cascade passage, shifts the inner and outer trailing shocks upward, and enlarges their included angle. The outlet back pressure plays a dominant role in entropy production, while the CO2 mass fraction and inlet temperature have weaker effects.
  • doi: 10.19805/j.cnki.jcspe.2026.250441
    To address the requirements for the long-distance transportation of nuclear steam supply from pressurized water reactors, three steam parameter improvement technologies were proposed, including electric heating, steam compression, and hybrid heating. Thermodynamic design and economic analysis were conducted for a 40 km steam transmission scenario. Results show that within the nuclear power plant, using an electric heater to reheat the steam to 290 ℃ can maintain a superheat degree of 12 K at the end of the steam pipeline, with the lowest cost increment per ton of steam at only 15.19 RMB. Installing two-stage steam compression in the heating network ensures superheated steam transportation, but the system equipment investment is high, increasing the cost by 29.34 RMB per ton. For the hybrid heating technology, mixing with 28% mass fraction of high-priced thermal power steam leads to a cost increase of 33.96 RMB per ton of externally supplied steam, accompanied by significant system fluctuations. Considering technical maturity, economic efficiency, and operational stability, the in-plant electric heating technology is the optimal solution for breaking through the bottlenecks in the long-distance transmission of nuclear steam supply.
  • doi: 10.19805/j.cnki.jcspe.2026.250459
    Multiple sets of stress relaxation tests were conducted on ST460TS, ST12T and Stellite 6 alloys used in ultra-supercritical steam turbine valves, under different initial stresses and at the valve service temperature of 630 °C. The influence of initial stress on stress relaxation was investigated for various materials. The stress relaxation curves were fitted using a four-order exponential decay function, and a full-stress-range creep constitutive model based on stress relaxation was derived. Results show that ST460TS and ST12T exhibit similar characteristics under different stress levels. The entire stress relaxation process can be divided into three stages: rapid relaxation, transitional relaxation and progressive steady state. The four-order exponential decay function can accurately describe the stress relaxation process of ST460TS and ST12T, and predict the relaxation limit. Stellite 6 exhibits stepwise relaxation behavior under high initial stress due to its low plasticity, while it shows continuous decay relaxation under low initial stress.
  • doi: 10.19805/j.cnki.jcspe.2026.250433
    To improve thermal management performance of proton exchange membrane fuel cells (PEMFCs) in underwater power platforms and to address the slow temperature control response caused by strong coupling and nonlinearity, a dual-actuator cooperative thermal management system based on fuzzy proportional- integral-derivative (PID) control was designed. An electro-thermal coupled mathematical model of the PEMFC was established, and a system simulation platform comprising the stack, water pump, and radiator was constructed. Results show that under dynamic current conditions, compared with conventional PID control, the fuzzy PID controller achieves faster and more stable stack temperature regulation by adjusting the water pump flow rate and radiator airflow in real time. The fuzzy PID reduces the temperature stabilization time by 323.1 s, lowers overshoot, improves efficiency, and maintains temperature control error within ±0.05 K. The system significantly enhances the robustness of PEMFCs under complex operating conditions.
  • doi: 10.19805/j.cnki.jcspe.2026.250177
    A novel bionic leaf vein reaction channel structure was constructed, and further investigated the effects of leaf vein bending amplitude and branching angle on the performance of fuel cell. Results show that the bionic leaf vein reaction channel can significantly enhance the performance of fuel cell, and increasing the bending amplitude substantially improves the reaction performance and electrical output performance of the fuel cell. The enhancement of the branching angle is dependent on the bending amplitude, i.e. slightly increasing the bending angle can improve performance, but increasing it significantly produces an inhibitory effect.
  • doi: 10.19805/j.cnki.jcspe.2026.250317
    In order to solve the problems of low system efficiency and insufficient economy caused by the high dimensional volatility of environmental data during the configuration of off-grid wind-solar electrolysis hydrogen production system, an optimization study was conducted on the capacity of photovoltaic, wind turbine, and storage battery in typical scenarios. First, a mathematical model of key components including the electrolyzer life model was constructed. Subsequently, scenario generation technology was innovatively adopted to compress the annual environmental data into 12 typical scenarios to reduce the complexity of optimization. Meanwhile, the minimization of levelized hydrogen production cost was taken as the objective function, and the factors of electrolyzer life decay and economic value discount of hydrogen were considered. Based on this, a two-layer nested optimization framework was designed: the inner layer realized the optimal power allocation under each typical scenario based on dynamic programming, and the outer layer optimized the system capacity allocation by particle swarm algorithm. Finally, the environmental data of Basu area in Tibet was used as a scenario case to obtain the optimal configuration under the target hydrogen production capacity of 1 000 m3/h, which verified the superiority of the proposed strategy in terms of system optimization performance and economy.
  • doi: 10.19805/j.cnki.jcspe.2026.250255
    To improve economic performance and grid coordination capability of wind-solar-hydrogen-methanol systems under electricity spot market environment, a collaborative optimization method for capacity configuration and operational scheduling was proposed. A mixed-integer linear programming model was established with the objective of maximizing the annual operating revenue of the system. The model was solved based on 8 760 h of wind-solar output and real-time electricity price data from the Mengxi region. Detailed capacity configuration and economic analyses were conducted, and the results were compared with those from a tiered electricity pricing scheme. Results indicate that under the spot market scenario, the system can flexibly schedule its operations in response to variations in renewable resources and electricity prices, thereby improving the utilization of renewable energy and power resources. This leads to increased annual revenue and reduced levelized cost of methanol. The proposed approach addresses the system planning problem under dual fluctuations of wind-solar output and electricity prices, providing a theoretical basis for the market-oriented operation of renewable-energy-based hydrogen production systems.
  • doi: 10.19805/j.cnki.jcspe.2026.250428
    To simplify propane steam reforming process and reduce hydrogen production cost, a shell-and-tube heat exchanger reforming reactor model was constructed using COMSOL. The temperature and velocity of hot air at the reactor inlet were selected as operating parameters. Simulations were conducted to analyze their effects on propane steam reforming and to determine the optimal operating conditions. Results show that under rated conditions, a higher hot-air inlet temperature promotes more complete propane reforming. Propane is fully consumed when the inlet temperature reached 900 K. Increasing the hot-air inlet velocity also favors the forward steam reforming reaction. At inlet velocities of 1.25 m/s and 1.5 m/s, propane is completely converted, with hydrogen mass fractions reaching 0.099 in both cases. Considering both energy consumption and reaction efficiency, the optimal operating condition is 900 K and 1.25 m/s.
  • doi: 10.19805/j.cnki.jcspe.2026.250389
    To enhance the regulation flexibility of thermal power units under the new power system, a full-process coupling scheme for frequency regulation of thermal power unit coupled with a molten salt system integrating a multi-heat-source thermal storage mode was designed. In this scheme, the multi-heat-source thermal storage mode of the electric-heating molten salt heat exchanger and extraction steam thermal storage was integrated, and a thermal release and utilization route based on molten salt heating the feedwater of the high-pressure heater was proposed. A dynamic model of the coupled system was established, and verification was carried out using actual data. Aiming at the full thermal storage and release process of the coupled system, a control strategy for the molten salt system coupled with thermal power units based on modal increment matching was proposed. Simulation results show that during load decrease process, under the mode of integrating multi-heat-source thermal storage, the system load stabilization time is shortened by 38.66% compared with the system without molten salt thermal storage, and the comprehensive ramping performance indicator is improved by 29.49% compared with the system with only extraction steam thermal storage. During load increase process, the proposed strategy based on power increment can effectively decouple the mutual influence between the thermal power unit and the molten salt thermal storage system. Compared with the high-pressure heater throttling scheme and the no-thermal-storage scheme, the comprehensive ramping performance indicator is increased by 15.01% and 21.18% respectively.
  • doi: 10.19805/j.cnki.jcspe.2026.250462
    For the under-construction 10 MW compressed air energy storage (CAES) demonstration system, the internal flow characteristics and energy consumption distribution features of the adjustable ejector were analyzed based on computational fluid dynamics simulation. An effective exhaust gas suction method was determined according to the actual operating conditions, and the effects of nozzle spacing, air storage tank operating pressure and needle process on the ejection performance of the adjustable ejector were investigated. Results show that under high back pressure conditions, the ejector can recover pressure energy by sucking exhaust gas through the central nozzle. The nozzle spacing may restrict the ejection performance by affecting the energy consumption of the internal flow field of the ejector. When the nozzle spacing is 22.5 mm, the maximum mass flow rate of the exhaust gas ejected into the turbine for work is 2.65 kg/s. Meanwhile, the ejection ratio of the adjustable ejector first increases and then decreases as the operating pressure reduces, and increases as the needle process decreases. When the operating pressure is 9.0 MPa, the maximum ejection ratio is 11.4%.
  • doi: 10.19805/j.cnki.jcspe.2026.250270
    A control strategy for hybrid energy storage-assisted thermal power units participating in primary frequency regulation was proposed to improve the frequency characteristics of a new power grid with a high proportion of new energy. Firstly, a primary frequency regulation model for thermal power-hybrid energy storage combined system considering the capacity degradation of energy-type energy storage was constructed. The frequency regulation dead zone of hybrid energy storage model was designed according to the frequency characteristics of power grid, and a local inertia compensation control strategy was proposed. On this basis, the model predictive control for primary frequency regulation of thermal power-hybrid energy storage combined system was implemented based on the prediction of load disturbances and system state variables, and rolling optimization was performed on the output regulation parameters of coal-fired units and various energy storage systems. Simulation results show that the proposed control strategy can effectively reduce the dynamic and steady-state frequency deviations of the system, decrease the output adjustment frequency of units and the charge-discharge depth of lithium batteries, and improve the power grid frequency quality. Compared with the traditional droop control, the amplitudes of the maximum dynamic frequency deviation and steady-state frequency deviation under step disturbance are reduced by 6.8% and 5.8% respectively, the root-mean-square frequency deviations under continuous disturbance and long-term disturbance are reduced by 8.2% and 7.2% respectively, and the percentages of frequency out-of-limit time are reduced by 10.5% and 16.1% respectively.
  • doi: 10.19805/j.cnki.jcspe.2026.250411
    An improved recognition algorithm was constructed by deeply integrating multi-task convolutional neural network (MTCNN) detection module, octave convolution (OctConv) feature optimization module and FaceNet recognition module. OctConv was introduced to replace the traditional convolution of MTCNN, a loss function for keypoint regression was added to output network (O-Net), a frequency-domain dynamic weight allocation mechanism was introduced to enhance OctConv module, and the triplet loss function was added during FaceNet training phase. Meanwhile, a novel facial image dataset covering various typical thermal power plant scenarios was constructed. Experimental results show that the accuracy of the proposed optimized algorithm reaches 95.2%. It performs excellently in the high-temperature area of the boiler, with the recognition accuracy increased from 87.6% of traditional MTCNN algorithm to 97.2%, effectively solving the problem of feature degradation caused by the reflection of high-temperature equipment. The detection speed of this algorithm reaches 24.7 frames per second, which is superior to that of MTCNN (22.3 frames per second) and convolutional neural network (CNN)-long short-term memory (LSTM) network (18.5 frames per second). The optimized algorithm improves accuracy and real-time performance, reduces computing resource consumption, can effectively meet the safety management requirements in the complex environment of thermal power plants, and enhances the intelligent level of safety management in thermal power plants.
  • doi: 10.19805/j.cnki.jcspe.2026.250285
    In transmission corridor inspection, insulator targets are generally small and exhibit significant scale variations, which can easily lead to false detections and missed detections of defects. To address these problems, an improved YOLOv8-dynamic enhanced window (DEW) based insulator defect detection algorithm was proposed. Firstly, a YOLOv8n detection network was constructed. To enhance the adaptive spatial aggregation capability of model for insulator targets with different poses and scales, the third-generation deformable convolution (DCNV3) was introduced. Partial original C2f modules and standard convolution modules in the backbone network were respectively replaced with C2f_DCNV3 and DCNV3_YOLO modules. Secondly, efficient channel attention (ECA) was introduced to enhance the recognition capability of model for target defect features. Finally, wise intersection over union loss (WIOU) was adopted to replace complete intersection over union loss (CIOU), so as to reduce the bounding box regression loss and improve the localization quality of prediction boxes. Experimental results show that the model file size, parameter quantity and computational complexity of the improved model are all slightly reduced, the number of floating-point operations is decreased by 1.3×109, and the detection speed reaches 26 frames/s. For insulator defect detection, the η mAP50 of reaches 98.3%, and the η mAP50:95 reaches 86.6%. Its overall performance is superior to other mainstream object detection algorithms.
  • doi: 10.19805/j.cnki.jcspe.2026.250440
    To reveal the migration characteristics of key ions and heavy metals during flash evaporation concentration of desulfurization wastewater, a rotary evaporation experimental setup was employed. The variations in pH, total dissolved solids (TDS), Cl-, NH+4, Hg, and other key ions and heavy metals, as well as the characteristics of evaporated crystalline products, were investigated under different temperatures and concentration ratios. Results show that with the increasing concentration ratio, the pH of the concentrate decreases while TDS content increases at all evaporation temperatures. During evaporation and concentration, NH+4 and Hg partially migrate to the gas phase, whereas Cl- migration to the gas phase is negligible. After 10-fold concentration, Cl- and NH+4 remain predominantly enriched in the concentrate, while Hg is mainly enriched in the condensate. The crystalline products exhibit in sheet structure, with CaSO4 as the main component and minor NaCl crystals.
  • doi: 10.19805/j.cnki.jcspe.2026.250235
    Wind and photovoltaic power generation, as mature renewable technologies, have been widely applied in power systems. However, their intermittency and uncertainty severely limit long-term supply reliability. To improve the economic performance of multi-energy power systems during the planning stage and enhance renewable energy accommodation, an optimal capacity configuration model for wind-PV-pumped storage considering construction sequencing and a flexibility retrofit scheme for thermal power units were proposed. First, an optimal capacity configuration model for wind-PV-pumped storage considering construction sequencing and a flexibility retrofit model for thermal power units were established, and the objective function as well as various constraints of the optimization model were formulated. The nonlinear parts were linearized using special ordered set of type 2 (SOS2) and McCormick convex envelope relaxation, transforming the original nonlinear problem into a mixed-integer linear programming problem. Based on historical wind, solar, and load data from a multi- energy power system, typical daily scenarios were generated using density peak clustering. Results verify the rationality of the proposed model and retrofit scheme.
  • doi: 10.19805/j.cnki.jcspe.2026.250265
    To address the increasing challenge of resource utilization of urban solid waste, a novel low-carbon supercritical water gasification (SCWG) system coupled with solid oxide fuel cell (SOFC) for combined heat and power (CHP) generation was proposed, which used coal and solid waste as co-fuels. The system employed chemical looping to reform the outlet syngas and capture carbon, while solar energy was introduced as the input to heat the gasification preheater and the calcium carbonate calciner. To further enhance waste heat recovery and carbon capture efficiency, the system was optimized by replacing the gasification system cooler with an organic Rankine cycle (ORC) for partial energy recovery, and by adopting anode fuel recirculation to improve CH4 reforming conversion. Based on these improvements, energy and exergy analyses were conducted to explore the effects of key parameters on the system performance. Results show that the improved system outperforms the original design in all performance metrics. The introduction of the ORC and fuel recirculation significantly increases power output and carbon capture. The improved system achieves high energy efficiency and carbon capture rate under design operating conditions: energy efficiency of 64.97%, power generation efficiency of 52.24%, exergy efficiency of 51.34%, and carbon capture rate of 94.34%, which are improvements of 2.03, 3.10, 3.01, and 18.15 percentage points, respectively. Increasing the gasification temperature and system water input or reducing gasification pressure all enhance hydrogen production in the gasification system. A lower coal-to-solid waste ratio improves the gasification conversion of the fuel. Higher SOFC operating temperature and pressure also improve system energy efficiency, with an optimal temperature range of 850-990 ℃. When the fuel recirculation ratio exceeds 0.75, near-zero CO2 emissions can be achieved.
  • doi: 10.19805/j.cnki.jcspe.2026.250390
    The Allam cycle is a power cycle fueled by natural gas using supercritical carbon dioxide as the working fluid, characterized by extremely high cycle efficiency, a near 100% carbon dioxide capture rate, and the potential for near-zero system emissions. A thermodynamic calculation model of the Allam cycle was developed, and a sensitivity analysis was conducted regarding the impacts of turbine inlet and outlet parameters, turbine cooling gas temperature, isentropic efficiency of power equipment, and the minimum cycle temperature on the system cycle efficiency. Based on the optimization results, a parameter scheme for a 100 MW class Allam cycle was proposed. The results indicate that the influence of turbine inlet pressure, inlet temperature, and outlet pressure on cycle efficiency exhibits a non-monotonic relationship. Effectively utilizing turbine exhaust waste heat and increasing the cooling gas temperature can improve the system cycle efficiency. Among the system power equipment, compared with the influence of compressor isentropic efficiency, turbine isentropic efficiency has a greater impact on the system cycle efficiency, with every 1 percentage point increase in turbine isentropic efficiency resulting in 0.32 percentage points increase in system cycle efficiency. Under the conditions of a turbine inlet pressure of 28 MPa, inlet temperature of 1 150 ℃, outlet pressure of 3.8 MPa, and a minimum cycle temperature of 24 ℃, the system cycle efficiency reaches 54.22%.
  • doi: 10.19805/j.cnki.jcspe.2026.250259
    To address the demands for deep peak shaving and low-carbon retrofitting of coal-fired power plants, a molten salt thermal energy storage-assisted carbon capture, utilization and storage (CCUS) coal-fired power generation system was proposed. Models of the thermal energy storage system and carbon capture system were developed using EBSILON and ASPEN PLUS software, respectively, enabling full-process simulation of a 630 MW unit. The economic was evaluated to study the mechanisms of thermal storage systems in enhancing peak-shaving capabilities and the impact of CCUS systems on carbon emissions. Results show that the thermal energy storage system adopts a dual-tank molten salt configuration with a designed storage capacity of 875 MW·h, achieving a thermal efficiency of 95%. The storage tank volume is 6 730 m3, with a unit cost of 175 yuan/(kW·h). Under various operating conditions, the CO2 capture rate of the CCUS system remains consistently at 90%, with an annual emission reduction of 1.654 6 million tons. After retrofitting, the unit's peak-shaving depth decreases from 40% to 0%, while the peak-shaving capacity increases by 180.1 MW, and the levelized cost of electricity (LCOE) changes from 0.374 8 yuan/(kW·h) to 0.365 3 yuan/(kW·h). The total project investment amounts to 2.374 billion yuan. Under the carbon trading price of 98 yuan/t, the net present value reaches 573 million yuan, with a payback period of approximately 19 years. Sensitivity analysis reveals that for every 10 yuan/t increase in carbon price, the LCOE decreases by 0.002 7 yuan/(kW·h), and for every 50 yuan/(MW·h) increase in peak-shaving compensation price, the LCOE decreases by 0.004 yuan/(kW·h). This study provides a technical pathway and economic assessment framework for the synergistic development of flexibility retrofitting and low-carbon transformation in coal-fired power units.
  • doi: 10.19805/j.cnki.jcspe.2026.250825
    To achieve the thermal-electric decoupling, a method of integrating a combined heat and power (CHP) unit with compressed air energy storage (CAES) was proposed. A thermodynamic model of a 300 MW CHP unit was developed based on Ebsilon software to analyze the variations in the unit's heat-power feasible region, energy utilization efficiency, and exergy efficiency. Additionally, a particle swarm optimization (PSO) algorithm based on position constraints was adopted to optimize the system's operation strategy with the objective of minimizing overall coal consumption. Results show that coupling with CAES can significantly expand the heat-power feasible region and enhance the deep peak shaving capability of the unit, providing a maximum increase of 35.0 MW in deep peak shaving power. When the boiler output and the power of the CAES module are fixed, the lower the heating load of the unit, the more significant the change in its energy utilization rate. Both the energy utilization efficiency and exergy efficiency of the unit are negatively correlated with charging power and positively correlated with discharging power. Within a typical daily cycle, the adjustment of charging and discharging power can increase the unit's energy utilization efficiency by up to 2.54% and the exergy efficiency by 1.41%. Furthermore, the unit can save 52.5 t/d of standard coal and reduce CO2 emissions by 136.5 t/d.