Home Most Read
Most Read
  • LIU Fei, CHEN Heng, LI Jinhang, ZHENG Hongxu, PAN Peiyuan
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 196-206. doi:10.19805/j.cnki.jcspe.2026.250259
    To address the demands for deep peak shaving and low-carbon retrofitting of coal-fired power plants, a molten salt thermal energy storage-assisted carbon capture, utilization and storage (CCUS) coal-fired power generation system was proposed. Models of the thermal energy storage system and carbon capture system were developed using EBSILON and ASPEN PLUS software, respectively, enabling full-process simulation of a 630 MW unit. The economic was evaluated to study the mechanisms of thermal storage systems in enhancing peak-shaving capabilities and the impact of CCUS systems on carbon emissions. Results show that the thermal energy storage system adopts a dual-tank molten salt configuration with a designed storage capacity of 875 MW·h, achieving a thermal efficiency of 95%. The storage tank volume is 6 730 m3, with a unit cost of 175 yuan/(kW·h). Under various operating conditions, the CO2 capture rate of the CCUS system remains consistently at 90%, with an annual emission reduction of 1.654 6 million tons. After retrofitting, the unit's peak-shaving depth decreases from 40% to 0%, while the peak-shaving capacity increases by 180.1 MW, and the levelized cost of electricity (LCOE) changes from 0.374 8 yuan/(kW·h) to 0.365 3 yuan/(kW·h). The total project investment amounts to 2.374 billion yuan. Under the carbon trading price of 98 yuan/t, the net present value reaches 573 million yuan, with a payback period of approximately 19 years. Sensitivity analysis reveals that for every 10 yuan/t increase in carbon price, the LCOE decreases by 0.002 7 yuan/(kW·h), and for every 50 yuan/(MW·h) increase in peak-shaving compensation price, the LCOE decreases by 0.004 yuan/(kW·h). This study provides a technical pathway and economic assessment framework for the synergistic development of flexibility retrofitting and low-carbon transformation in coal-fired power units.
  • ZHENG Haoyu, ZHOU Jiahui, XU Gang, TONG Bing, WANG Haiming, XUE Xiaojun
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 84-93,195. doi:10.19805/j.cnki.jcspe.2026.250255
    To improve economic performance and grid coordination capability of wind-solar-hydrogen-methanol systems under electricity spot market environment, a collaborative optimization method for capacity configuration and operational scheduling was proposed. A mixed-integer linear programming model was established with the objective of maximizing the annual operating revenue of the system. The model was solved based on 8 760 h of wind-solar output and real-time electricity price data from the Mengxi region. Detailed capacity configuration and economic analyses were conducted, and the results were compared with those from a tiered electricity pricing scheme. Results indicate that under the spot market scenario, the system can flexibly schedule its operations in response to variations in renewable resources and electricity prices, thereby improving the utilization of renewable energy and power resources. This leads to increased annual revenue and reduced levelized cost of methanol. The proposed approach addresses the system planning problem under dual fluctuations of wind-solar output and electricity prices, providing a theoretical basis for the market-oriented operation of renewable-energy-based hydrogen production systems.
  • LU Shuyin, WU Qingzhe, YANG Kaicheng, GU Yujiong
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 207-216. doi:10.19805/j.cnki.jcspe.2026.250825
    To achieve the thermal-electric decoupling, a method of integrating a combined heat and power (CHP) unit with compressed air energy storage (CAES) was proposed. A thermodynamic model of a 300 MW CHP unit was developed based on Ebsilon software to analyze the variations in the unit's heat-power feasible region, energy utilization efficiency, and exergy efficiency. Additionally, a particle swarm optimization (PSO) algorithm based on position constraints was adopted to optimize the system's operation strategy with the objective of minimizing overall coal consumption. Results show that coupling with CAES can significantly expand the heat-power feasible region and enhance the deep peak shaving capability of the unit, providing a maximum increase of 35.0 MW in deep peak shaving power. When the boiler output and the power of the CAES module are fixed, the lower the heating load of the unit, the more significant the change in its energy utilization rate. Both the energy utilization efficiency and exergy efficiency of the unit are negatively correlated with charging power and positively correlated with discharging power. Within a typical daily cycle, the adjustment of charging and discharging power can increase the unit's energy utilization efficiency by up to 2.54% and the exergy efficiency by 1.41%. Furthermore, the unit can save 52.5 t/d of standard coal and reduce CO2 emissions by 136.5 t/d.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 124-137. doi:10.19805/j.cnki.jcspe.2026.250270
    A control strategy for hybrid energy storage-assisted thermal power units participating in primary frequency regulation was proposed to improve the frequency characteristics of a new power grid with a high proportion of new energy. Firstly, a primary frequency regulation model for thermal power-hybrid energy storage combined system considering the capacity degradation of energy-type energy storage was constructed. The frequency regulation dead zone of hybrid energy storage model was designed according to the frequency characteristics of power grid, and a local inertia compensation control strategy was proposed. On this basis, the model predictive control for primary frequency regulation of thermal power-hybrid energy storage combined system was implemented based on the prediction of load disturbances and system state variables, and rolling optimization was performed on the output regulation parameters of coal-fired units and various energy storage systems. Simulation results show that the proposed control strategy can effectively reduce the dynamic and steady-state frequency deviations of the system, decrease the output adjustment frequency of units and the charge-discharge depth of lithium batteries, and improve the power grid frequency quality. Compared with the traditional droop control, the amplitudes of the maximum dynamic frequency deviation and steady-state frequency deviation under step disturbance are reduced by 6.8% and 5.8% respectively, the root-mean-square frequency deviations under continuous disturbance and long-term disturbance are reduced by 8.2% and 7.2% respectively, and the percentages of frequency out-of-limit time are reduced by 10.5% and 16.1% respectively.
  • ZHENG Yu, YE Xuemin, CHEN Pengqiang, WANG Yao, LI Chunxi
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 173-185. doi:10.19805/j.cnki.jcspe.2026.250265
    To address the increasing challenge of resource utilization of urban solid waste, a novel low-carbon supercritical water gasification (SCWG) system coupled with solid oxide fuel cell (SOFC) for combined heat and power (CHP) generation was proposed, which used coal and solid waste as co-fuels. The system employed chemical looping to reform the outlet syngas and capture carbon, while solar energy was introduced as the input to heat the gasification preheater and the calcium carbonate calciner. To further enhance waste heat recovery and carbon capture efficiency, the system was optimized by replacing the gasification system cooler with an organic Rankine cycle (ORC) for partial energy recovery, and by adopting anode fuel recirculation to improve CH4 reforming conversion. Based on these improvements, energy and exergy analyses were conducted to explore the effects of key parameters on the system performance. Results show that the improved system outperforms the original design in all performance metrics. The introduction of the ORC and fuel recirculation significantly increases power output and carbon capture. The improved system achieves high energy efficiency and carbon capture rate under design operating conditions: energy efficiency of 64.97%, power generation efficiency of 52.24%, exergy efficiency of 51.34%, and carbon capture rate of 94.34%, which are improvements of 2.03, 3.10, 3.01, and 18.15 percentage points, respectively. Increasing the gasification temperature and system water input or reducing gasification pressure all enhance hydrogen production in the gasification system. A lower coal-to-solid waste ratio improves the gasification conversion of the fuel. Higher SOFC operating temperature and pressure also improve system energy efficiency, with an optimal temperature range of 850-990 ℃. When the fuel recirculation ratio exceeds 0.75, near-zero CO2 emissions can be achieved.
  • LUO Wei, WANG Zenghui, ZHENG Bo, CAI Wei, LAN Pingxia
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 1-8. doi:10.19805/j.cnki.jcspe.2026.250567
    For boiler state monitoring in complex environment, a single sensor often fails to provide comprehensive and accurate information. A monitoring method based on multisensor fusion was proposed, which enhanced system performance by integrating data from different types of sensors. The principles of system construction and the theories and optimization strategies of data fusion algorithms, such as Kalman filtering and KalmanNet, were analyzed. Results show that multisensor fusion significantly reduces prediction errors, with Kalman filtering reducing the mean square error of sensor predictions by 37% to 50% and KalmanNet improving accuracy by over 60%. In terms of overall model performance, KalmanNet with adaptive feedback achieves an accuracy of 93.2%. Despite its higher computational cost, KalmanNet demonstrates superior precision and robustness under complex state monitoring. The proposed multisensor fusion method not only improves state estimation accuracy and system stability but also offers significant application value for industrial safety monitoring.
  • WANG Daolei, YANG Tao, YAN Peng, LIU Hongda, ZHU Rui
    Journal of Chinese Society of Power Engineering. 2026, 46(10): 146-153,216. doi:10.19805/j.cnki.jcspe.2026.250285
    In transmission corridor inspection, insulator targets are generally small and exhibit significant scale variations, which can easily lead to false detections and missed detections of defects. To address these problems, an improved YOLOv8-dynamic enhanced window (DEW) based insulator defect detection algorithm was proposed. Firstly, a YOLOv8n detection network was constructed. To enhance the adaptive spatial aggregation capability of model for insulator targets with different poses and scales, the third-generation deformable convolution (DCNV3) was introduced. Partial original C2f modules and standard convolution modules in the backbone network were respectively replaced with C2f_DCNV3 and DCNV3_YOLO modules. Secondly, efficient channel attention (ECA) was introduced to enhance the recognition capability of model for target defect features. Finally, wise intersection over union loss (WIOU) was adopted to replace complete intersection over union loss (CIOU), so as to reduce the bounding box regression loss and improve the localization quality of prediction boxes. Experimental results show that the model file size, parameter quantity and computational complexity of the improved model are all slightly reduced, the number of floating-point operations is decreased by 1.3×109, and the detection speed reaches 26 frames/s. For insulator defect detection, the η mAP50 of reaches 98.3%, and the η mAP50:95 reaches 86.6%. Its overall performance is superior to other mainstream object detection algorithms.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 37-43,73. doi:10.19805/j.cnki.jcspe.2026.250441
    To address the requirements for the long-distance transportation of nuclear steam supply from pressurized water reactors, three steam parameter improvement technologies were proposed, including electric heating, steam compression, and hybrid heating. Thermodynamic design and economic analysis were conducted for a 40 km steam transmission scenario. Results show that within the nuclear power plant, using an electric heater to reheat the steam to 290 ℃ can maintain a superheat degree of 12 K at the end of the steam pipeline, with the lowest cost increment per ton of steam at only 15.19 RMB. Installing two-stage steam compression in the heating network ensures superheated steam transportation, but the system equipment investment is high, increasing the cost by 29.34 RMB per ton. For the hybrid heating technology, mixing with 28% mass fraction of high-priced thermal power steam leads to a cost increase of 33.96 RMB per ton of externally supplied steam, accompanied by significant system fluctuations. Considering technical maturity, economic efficiency, and operational stability, the in-plant electric heating technology is the optimal solution for breaking through the bottlenecks in the long-distance transmission of nuclear steam supply.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 9-17,51. doi:10.19805/j.cnki.jcspe.2026.250284
    With the development of coal-fired power transformation, there is an increasing need for large-scale scheduling and other macro decision-making in the power grid. Previous reliability prediction methods for single units cannot meet the power grid's demand for reliability information of unit sets. In order to accurately and efficiently predict the reliability of coal-fired power unit sets, a reliability prediction model of unit sets based on Apriori algorithm optimized back propagation (BP) neural network input (Apriori-BP) was proposed. The Apriori algorithm measured the correlation between the influencing factors and the prediction target based on their impact, which could more accurately measure the overall correlation between the composite influencing factors and the prediction target, thereby better optimizing the model input. Apply the Apriori-BP prediction model to the actual power grid, predict the reliability of multiple different sets of units, and compare the prediction errors with the grey relational analysis (GRA)-BP model and principal components analysis (PCA)-BP model. Results indicate that the Apriori-BP model has the highest prediction accuracy, with root mean square error and mean absolute error of 0.021 4 and 0.009 7, and better generalization ability and robustness.
  • Journal of Chinese Society of Power Engineering. 2026, 46(10): 44-51. doi:10.19805/j.cnki.jcspe.2026.250459
    Multiple sets of stress relaxation tests were conducted on ST460TS, ST12T and Stellite 6 alloys used in ultra-supercritical steam turbine valves, under different initial stresses and at the valve service temperature of 630 °C. The influence of initial stress on stress relaxation was investigated for various materials. The stress relaxation curves were fitted using a four-order exponential decay function, and a full-stress-range creep constitutive model based on stress relaxation was derived. Results show that ST460TS and ST12T exhibit similar characteristics under different stress levels. The entire stress relaxation process can be divided into three stages: rapid relaxation, transitional relaxation and progressive steady state. The four-order exponential decay function can accurately describe the stress relaxation process of ST460TS and ST12T, and predict the relaxation limit. Stellite 6 exhibits stepwise relaxation behavior under high initial stress due to its low plasticity, while it shows continuous decay relaxation under low initial stress.