Science & Technology Review
|
2015, 33(18): 20-22
• Articles •
PM10 and PM2.5 emission control by electrostatic precipitator (ESP) for coal-fired power plants VI: Optimization of HV power source with 75 t/h industrial boiler (Jiaxing Xiexin Environmental Power Plant)
Full
MA Hongjin, XU Jianyuan, WANG Shilong, HAN Ping, ZHENG Qinzhen, LI Shuran, YAN Keping
Affiliations
Published: 2015-09-28
doi: 10.3981/j.issn.1000-7857.2015.18.002
Outline
This paper discusses the performance of a four-field electrostatic precipitator (ESP) used for a 75 t/h industrial coal-fired boiler. By using four traditional single-phase transformer-rectifiers (T/Rs), the PM10 and PM2.5 concentrations at the ESP outlet are around 120.4~219.7 and 9.6~22.3 mg·Nm-3, respectively. After retrofitting the four rectifiers with four ZH type three-phase T/Rs, the PM10 and PM2.5 concentration are about 6~17 and 1.8~3.3 mg·Nm-3, respectively. The PM2.5 to PM10 ratio ranges from 35% to 52%.
industrial boiler
/
electrostatic precipitation
/
PM2.5
/
three-phase T/Rs power source
马洪金, 徐建元, 王仕龙, 韩平, 郑钦臻, 李树然, 闫克平.
燃煤电厂电除尘PM10和PM2.5的排放控制VI:以75t/h工业锅炉为例分析讨论电除尘的运行(嘉兴协鑫环保热电分析).
科技导报,
2015
, 33
(18)
: 20
-22
.
DOI: 10.3981/j.issn.1000-7857.2015.18.002
MA Hongjin, XU Jianyuan, WANG Shilong, HAN Ping, ZHENG Qinzhen, LI Shuran, YAN Keping.
PM10 and PM2.5 emission control by electrostatic precipitator (ESP) for coal-fired power plants VI: Optimization of HV power source with 75 t/h industrial boiler (Jiaxing Xiexin Environmental Power Plant)[J].
Science & Technology Review,
2015
, 33
(18)
: 20
-22
.
DOI: 10.3981/j.issn.1000-7857.2015.18.002
Year 2015 volume 33 Issue 18
PDF
814
289
Cite this Article
BibTeX
Article Info
doi: 10.3981/j.issn.1000-7857.2015.18.002
- Receive Date:2015-05-20
- Online Date:2015-10-16
- Published:2015-09-28