收藏切换
Evolution of indoor aerosol in Emperor Qin's Terra-cotta Museum and its influential factors
收藏切换
PDF
Science & Technology Review | 2015, 33(6) : 46 - 53
Less
收藏切换
Science & Technology Review | 2015, 33(6): 46-53
• Spescial Issues •
Evolution of indoor aerosol in Emperor Qin's Terra-cotta Museum and its influential factors
Full
LI Hua1,2,3, HU Tafeng3, CAO Junji3,4, JIA Wenting3, MA Tao5, WANG Chunyan1
Affiliations
    1. Key Scientific Research Base of Ancient Polychrome Pottery Conservation, SACH; Emperor Qin Shihuang's Mausoleum Site Museum, Xi'an 710600, China;
    2. University of Chinese Academy of Sciences, Beijing 100049, China;
    3. Key Lab of Aerosol Chemistry & Physics, Institute of Earth Environment, Chinese Academy of Sciences, Xi'an 710061, China;
    4. Institute of Global Environmental Change, Xi'an Jiaotong University, Xi'an 710049, China;
    5. Shaanxi Institute for the Preservation of Cultural Heritage, Xi'an 710075, China
Published: 2015-03-28 doi: 10.3981/j.issn.1000-7857.2015.06.007
Outline
收藏切换
Long-term measurement results of indoor air quality (IAQ) from 1989 to 2013 inside Pit No.1, the largest display hall in Emperor Qin's Terra-cotta Museum (QTM) were used to evaluate the effectiveness of measures for conservation environment improvement of antiques. By comparing the results of sampling campaigns in 2013 with databases in 1989, 2004-2005, 2006-2007, and 2011, seasonal and inter-annual variations in microclimate and aerosol chemical compositions were incorporated in estimating the probable influences of management of surroundings, tourist flow, excavation and restoration task, and renovation and/or new construction work on IAQ in the QTM. Since the implementation of the environmental policies of 1990s, a significant decrease of indoor particulate matter mass for the QTM has been achieved. The mass concentrations of summer TSP decreased from 540.0 μg·m-3 in 1994 to 172.4 μg·m-3 in 2004, as well as the winter TSP decreased from 380.0 μg·m-3 in 1994 to 312.5 μg·m-3 in 2005. The mass concentration of summer PM2.5 decreased from 108.4 μg·m-3 in 2004 to 65.7 μg·m-3 in 2013, as well as the winter PM2.5 from 242.3 μg·m-3 in 2005 to 98.6 μg·m-3 in 2013. However, it is noted that potential hazards due to the secondary particulate acidic species in indoor air should still be considered to ensure the long-term preservation and conservation of the museum's artifact collection.
aerosol  /  indoor air quality  /  tourism planning  /  environmental policy  /  museum
李华, 胡塔峰, 曹军骥, 贾文婷, 马涛, 王春燕. 秦俑博物馆室内气溶胶的演化特征及影响因素. 科技导报, 2015 , 33 (6) : 46 -53 . DOI: 10.3981/j.issn.1000-7857.2015.06.007
LI Hua, HU Tafeng, CAO Junji, JIA Wenting, MA Tao, WANG Chunyan. Evolution of indoor aerosol in Emperor Qin's Terra-cotta Museum and its influential factors[J]. Science & Technology Review, 2015 , 33 (6) : 46 -53 . DOI: 10.3981/j.issn.1000-7857.2015.06.007
Year 2015 volume 33 Issue 6
PDF
571
185
Cite this Article
BibTeX
Article Info
doi: 10.3981/j.issn.1000-7857.2015.06.007
  • Receive Date:2015-01-23
  • Online Date:2015-04-10
  • Published:2015-03-28
Article Data
Affiliations
History
  • Received:2015-01-23
  • Revised:2015-02-15
Affiliations
References
Share
https://castjournals.cast.org.cn/joweb/kjdb/EN/10.3981/j.issn.1000-7857.2015.06.007
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT