Home Archive
Archive
2026 Volume 46 Issue 1  Published: 2026-01-15
   Next
  • doi: 10.19805/j.cnki.jcspe.2026.240620
    In order to study the dynamic characteristics of the cooling wall in the ultra-supercritical boiler, a dynamic simulation model of the cooling wall in a 1 100 MW ultra-supercritical boiler was established under the condition that the heat load distribution along the height of the cooling wall was uneven. The distribution of the working fluid temperature and the metal wall temperature along the height of the cooling wall were simulated. The dynamic response characteristics of the main thermodynamic parameters of the working fluid and the metal wall temperature were analyzed when the flow rate at the cooling wall inlet was step-disturbed. Results show that under the design condition of 50%THA(turbine heat acceptance), the dryness of the working fluid at the height of 37.5 m in the cooling wall reaches 0.994, and the inner wall temperature reaches up to 466.1 ℃. At 30%THA, the peak temperature of the inner wall at 42.0 m reaches 375.3 ℃. The larger the flow steps, the longer the dynamic response time is, the heat transfer deterioration is aggravated, and the wall temperature in the evaporation and drying region increases. At 50%THA, after the flow step is reduced by 5.0%, the wall temperature at 36.0 m reaches 547.9 ℃ in this process, and no overheating occurs. After the flow stability, compared with the design flow, when the flow step is reduced by 2.5% and 5.0%, the inner wall temperature at 50%THA and 34.5 m will be increased by 5.6 and 17.2 K respectively.
  • doi: 10.19805/j.cnki.jcspe.2026.240663
    To investigate the effect of biomass co-firing on the lowest steady combustion load of the boiler, a 1 000 MW ultra-supercritical swirl-opposed boiler was taken as the research object. The combustion conditions of pure coal and the addition of cotton stalk(CS) with a co-firing ratio of 10% were simulated under different loads in the boiler. The temperature distribution and oxygen concentration distribution in the furnace under different loads were analyzed, and the evolution of the minimum stable combustion load of the boiler after co-firing biomass was explored. Results show that compared with pure coal conditions, the area with the temperature above 1 400 K of the central section of the burner increases after co-firing cotton stalks, the ignition distance is shortened by 0.24%-3.45%, the oxygen concentration at the furnace outlet increases by 0.22%-0.24%, and the combustion stability is greatly enhanced. The lowest steady combustion load of the designed coal is 40%, and the lowest steady combustion load of the boiler mixed with CS can be reduced to 30%. Therefore, biomass-mixed combustion can effectively enhance the steady combustion performance and decrease the lowest steady combustion load of the swirl-opposed boiler, and thus the peaking capability of the boiler can be promoted.
  • doi: 10.19805/j.cnki.jcspe.2026.240791
    To address the technical difficulties of slow load response in circulating fluidized bed (CFB) power units due to the presence of large amounts of inert bed material on the fuel side of the boiler, a CFB power unit primarily fueled by coal gangue was focused on. A dynamic simulation model of the power unit's thermal system was established and validated, obtaining performance of key thermodynamic parameters such as output power, main steam temperature, main steam pressure, bed temperature, boiler evaporation rate and cycle efficiency during the load ramp-up process. To improve the power unit's load ramp-up capability, an optimization scheme involving dynamic co-firing of pulverized coal in the upper part of the CFB furnace was proposed to mitigate the inertial effects of coal gangue combustion. Results show that at the load ramp-up rate of 3%/min, the optimization scheme reduces the maximum deviations of output power, main steam pressure, main steam temperature, reheat steam temperature and bed temperature to 1.31%, 0.81%, 2.3 K, 3.5 K and 27.8 K respectively, all within the specified range of the DL/T 657—2015 Code for Acceptance Test of Modulating Control System in Fossil Fuel Power Plant standard. With the optimization scheme, the maximum allowable load ramp-up rate of the CFB power unit increases from 2%/min to 3%/min, while slightly improving the power unit's thermal economy.
  • doi: 10.19805/j.cnki.jcspe.2026.240619
    Establishing an accurate model of the pulverized-coal preparation system and analyzing its operational characteristics are the key theoretical foundations for optimizing the system operational control. By incorporating the coupling relationship between the internal coal inventory of the coal mill and its operational parameters, and considering the impact of pulverized coal fineness on the output capacity of the coal pulverizing system, a gray box model of pulverized-coal preparation system with roller-type medium speed coal mills, encompassing key equipment such as coal mills, primary air fans, and coal conveying pipelines, was constructed. Based on this model, the steady-state operational characteristics of the pulverized-coal preparation system under single-parameter and fixed air-to-coal ratio conditions, as well as its dynamic operational characteristics during the startup process, were analyzed. Results indicate that when the coal feed rate (mass flow rate) increases from 12 kg/s to 26 kg/s, the specific energy consumption for coal grinding decreases from 10.26 kW·h/t to 7.14 kW·h/t, representing a reduction of 30.4%. Under a fixed air-coal ratio, the primary air temperature and the mass fraction of moisture in raw coal are identified as the key factors determining the outlet temperature of pulverized coal. When the air-coal ratio is 1.6 and the primary air temperature rises from 260 ℃ to 300 ℃, the outlet air-coal mixture temperature increases by 19.03%. During the load-increasing process, the output capacity of the coal pulverizing system is delayed by 102 s.
  • doi: 10.19805/j.cnki.jcspe.2026.240642
    To address the issue of unclear vibration transmission paths in auxiliary steam turbine-generator units, taking a high-speed auxiliary steam turbine-generator unit as the research object, a complete rotor-bearing-stator model of the unit was established, and a vibration transmission model was constructed based on operational transfer path analysis (OTPA). After which, the vibration transmission characteristics of the unit were analyzed. First of all, the finite element method was applied to obtain the frequency response function of each transmission path of the unit. Taking into account the excitation sources such as rotor imbalance, pulsating vapor force and unbalanced magnetic tension, the singular value decomposition technique was adopted to reduce the noise and synthesize the input signals at the bearing seats, the transfer function matrix of the relationship between the inputs and outputs of various paths was constructed, and the vibration contribution of the different paths to the stator shell was analyze to clarify the main vibration transmission paths. Results show that the main vibration paths of the stator shell vibration at each measurement point originate from the two bearing housings of the auxiliary steam turbine, especially the generator-side bearing housing has the largest vibration contribution. The stator shell vibration can be effectively reduced by optimizing the adjustment of the structural intrinsic characteristics of the bearing housings and the phase difference of the rotor imbalance force, with the maximum amplitude being reduced from 364 μm to 51 μm. The research results can provide a reference for tracing the vibration of auxiliary steam turbine-generator units and optimizing the diagnosis of faults.
  • doi: 10.19805/j.cnki.jcspe.2026.250282
    In the calculation of a regional film cooling effectiveness covered by arrayed discrete holes, conventional computational fluid dynamics (CFD) simulations are confronted with the challenges of complex grid modeling and high computation consumption. A parameterized kernel function was proposed to describe the distribution characteristics of a single fan-shaped hole and then to predict the film cooling efficiency. Integrating data-driven machine learning technique with the Sellers film cooling efficiency superposition method, the efficient prediction of cooling efficiency distribution in the coverage area of group holes was realized. Based on the parametric "Kernel" model, the cooling effectiveness distribution for both single and triple in-line rows of 7-7-7 fan-shaped holes were successfully replicated. Furthermore, In the given region, the layout of in-line group holes with the highest average cooling efficiency in the region was obtained with integer programming method. Results show that the parametric "Kernel" model can accurately reflect the distribution characteristics of cooling efficiency in the film hole coverage area, overcoming the limitation of traditional correlation equations that only predict spanwise average cooling efficiency, and significantly reduce the number of samples required for machine learning, which can be applied to the prediction of film cooling efficiency under different working conditions.
  • doi: 10.19805/j.cnki.jcspe.2026.240655
    In order to improve the atomization performance of the pressure swirl nozzle used for spray cooling and optimize the structural parameters of the nozzle, simulation analysis of the swirl nozzle based on the volume-of-fluid function (VOF) method was carried out, and orthogonal tests were used to analyze the significance of the influence of each parameter on the thickness of the liquid film and the spray angel of atomization, then the structural parameters of the nozzle were optimized. Results show that the outlet length L₁, outlet diameter D and the number of cyclone holes N have a more significant effect on the atomization performance of the nozzle, and the height of the cyclone chamber H has a smaller effect on the atomization performance. Increasing the nozzle outlet length L₁ can reduce the liquid film thickness and atomization spray angel; increasing the outlet diameter D can increase the liquid film thickness and atomization spray angel; increasing the number of cyclone holes N will make the liquid film become thicker and the atomization spray angel become smaller; increasing the height of the cyclone chamber H will make the liquid film thickness decrease firstly and then increase, and the atomization spray angel decrease. When the outlet length L₁ is 2 mm, the outlet diameter D is 10 mm, the height of the cyclone chamber H is 16 mm, and the number of cyclone holes N is 6, the atomization performance is optimal. Compared with the original model, the atomization spray angel of the optimized nozzle is increased by 16.8%, and its liquid film thickness is decreased by 32.4%.
  • doi: 10.19805/j.cnki.jcspe.2026.240512
    Aerodynamic shape optimization methods are important means to enhance the aerodynamic efficiency of airfoils and alleviate dynamic stall, but require repeatedly invoking precise yet time-consuming computational fluid dynamics (CFD) simulations, resulting in high computational costs. An optimization method based on surrogate model was proposed to replace CFD calculations, thereby conducting optimization of dynamic stall characteristics of airfoils. The surrogate model was constructed using the Gaussian process regression model, and the accuracy of the model was continuously improved by adopting the point addition criterion. The surrogate model was verified using the normalized root mean square error, and the feasibility of the optimization framework was verified using the S809 airfoil as the research object. Results show that compared with the baseline airfoil, the average drag coefficient and moment coefficient of the optimized airfoil are reduced by 32.87% and 23.74%, respectively,the aerodynamic performence was significantly improved. And the change in the aerodynamic shape accelerates the velocity recovery of the suction surface near the wall and reduces the boundary layer thickness.
  • doi: 10.19805/j.cnki.jcspe.2026.240722
    To enhance the accuracy of short-term photovoltaic power forecasting, a segmented multi-channel independent short-term photovoltaic power prediction method optimized by a similar day algorithm with consideration of photovoltaic equipment performance degradation factors was proposed. Firstly, the photovoltaic input data were processed in PTransformer model with time period and channel independent methods to reduce the spatial complexity and improve the attention of long-term data series. Secondly, the encoder model of Transformer was applied to capture the dependencies between photovoltaic sequence features through its own attention mechanism for short-term photovoltaic power prediction. Finally, the PTransformer model was optimized using its power data to improve the lag of the power data by applying the angle cosine distance to calculate the similarity and considering the performance degradation factors of the photovoltaic equipment to determine the similar day. Results show that compared with typical short-term photovoltaic power prediction method, the proposed method has faster training speed, higher prediction accuracy and better prediction results for photovoltaic power under complex weather conditions.
  • doi: 10.19805/j.cnki.jcspe.2026.240651
    A novel solid-state hydrogen storage cylinder with a helical coil structure was proposed, and it was integrated with a fuel cell to form a coupled system. A mathematical model was developed for analysis, and the internal temperature and hydrogen mass fraction distribution of the solid-state hydrogen storage cylinder under different heat exchange structures were obtained. Moreover, the influence of the fuel cell operating temperature on the performance of the solid-state hydrogen storage cylinder was explored. Results show that compared with straight pipes and single-helix coils, the double-helix coil has a higher heat transfer rate, which can significantly improve the hydrogen release rate of the solid-state hydrogen storage cylinder and the power generation efficiency of the fuel cell. Increasing of the fuel cell operating temperature can enhance the initial hydrogen release rate of the solid-state hydrogen storage cylinder, but has little effect on the total hydrogen release capacity.
  • doi: 10.19805/j.cnki.jcspe.2026.240653
    The research progress and application status of molten salt thermal energy storage technology have been systematically reviewed, and its coupling technologies with solar thermal power generation, coal-fired power plants, and electric heating systems have been thoroughly explored. This encompasses the energy coupling mechanisms between molten salt thermal energy storage and various energy input systems, as well as its role in optimizing power system dispatch. The introduction of molten salt thermal energy storage technology has significantly enhanced the stability and efficiency of solar thermal power plants, improved the peak-regulation capacity and flexibility of coal-fired power plants, facilitated the integration of renewable energy and the decarbonization process, and increased the regulatory capacity of solar and wind energies. With the support of molten salt thermal energy storage technology, renewable energy can be efficiently converted into stable high-temperature heat flows, addressing the impact of the volatility and intermittency of renewable energy on the power grid and making it an important component of the new power system. In the next step, molten salt thermal energy storage technology will shift towards large-scale coordinated dispatch of multiple energy sources. Large-scale energy bases may become the primary direction for the application of molten salt thermal energy storage, and its application scenarios still need to be further expanded.