Journal of Chinese Society of Power Engineering
|
2026, 46(10): 173-185
Thermodynamic Analysis of Supercritical Water Coal/Solid Waste Co-gasification CHP System Based on WGS-CAL Carbon Capture
Full
ZHENG Yu1, YE Xuemin1, CHEN Pengqiang2, WANG Yao1, LI Chunxi1
Affiliations
1 Hebei Key Laboratory of Low Carbon and High Efficiency Power Generation Technology, North China Electric Power University, Baoding 071003, Hebei Province, China;
2 Inner Mongolia Electric Power Survey & Design Institute Co., Ltd., Hohhot 010011, Inner Mongolia Autonomous Region, China
doi: 10.19805/j.cnki.jcspe.2026.250265
Outline
To address the increasing challenge of resource utilization of urban solid waste, a novel low-carbon supercritical water gasification (SCWG) system coupled with solid oxide fuel cell (SOFC) for combined heat and power (CHP) generation was proposed, which used coal and solid waste as co-fuels. The system employed chemical looping to reform the outlet syngas and capture carbon, while solar energy was introduced as the input to heat the gasification preheater and the calcium carbonate calciner. To further enhance waste heat recovery and carbon capture efficiency, the system was optimized by replacing the gasification system cooler with an organic Rankine cycle (ORC) for partial energy recovery, and by adopting anode fuel recirculation to improve CH4 reforming conversion. Based on these improvements, energy and exergy analyses were conducted to explore the effects of key parameters on the system performance. Results show that the improved system outperforms the original design in all performance metrics. The introduction of the ORC and fuel recirculation significantly increases power output and carbon capture. The improved system achieves high energy efficiency and carbon capture rate under design operating conditions: energy efficiency of 64.97%, power generation efficiency of 52.24%, exergy efficiency of 51.34%, and carbon capture rate of 94.34%, which are improvements of 2.03, 3.10, 3.01, and 18.15 percentage points, respectively. Increasing the gasification temperature and system water input or reducing gasification pressure all enhance hydrogen production in the gasification system. A lower coal-to-solid waste ratio improves the gasification conversion of the fuel. Higher SOFC operating temperature and pressure also improve system energy efficiency, with an optimal temperature range of 850-990 ℃. When the fuel recirculation ratio exceeds 0.75, near-zero CO2 emissions can be achieved.
CHP system
/
supercritical water gasification
/
carbon capture and storage
/
SOFC
/
thermodynamic analysis
郑宇, 叶学民, 陈朋强, 王尧, 李春曦.
基于WGS-CAL碳捕集的超临界水煤/固废共气化热电联产系统热力学分析.
动力工程学报,
2026
, 46
(10)
: 173
-185
.
DOI: 10.19805/j.cnki.jcspe.2026.250265
ZHENG Yu, YE Xuemin, CHEN Pengqiang, WANG Yao, LI Chunxi.
Thermodynamic Analysis of Supercritical Water Coal/Solid Waste Co-gasification CHP System Based on WGS-CAL Carbon Capture[J].
Journal of Chinese Society of Power Engineering,
2026
, 46
(10)
: 173
-185
.
DOI: 10.19805/j.cnki.jcspe.2026.250265
Year 2026 volume 46 Issue 10
127
17
Cite this Article
BibTeX
Article Info
doi: 10.19805/j.cnki.jcspe.2026.250265
- Receive Date:2025-05-09
- Online Date:2026-11-06