  • Wei LIU, Xinyue ZHANG, Wenbo ZOU, Hui XU, Baoming NING
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 80-88.

    Coating thickness of enteric-coated tablets is a critical quality attribute. Raman mapping has unique advantages in analysis of the microstructure of pharmaceutical preparations. In this paper, Raman mapping was used to determine the coating thickness and coating uniformity of 7 batches of aspirin enteric-coated tablets from different sources,and Micro-CT three-dimensional imaging technology was used to verify the difference in coating uniformity of aspirin enteric-coated tablets. The results showed that the coating thickness was in sequence as follows: products from manufacturer A>products from manufacturer B>reference preparation>products from manufacturer C>self-made tablets E>products from manufacturer D. The coating layers of the products from manufacturer A, manufacturer B, manufacturer D and self-made tablets E were relatively uniform, and the coating uniformity of the reference preparations and the products from manufacturer C were poor, indicating that Raman spectroscopy could be used to determine the thickness of tablet coating layers and the evaluation of coating process.

  • Yan WANG, Yi MOU, Shuai WEN, Xing LI, Yao ZHAO, Dongkai WANG
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 89-95.

    The effect of crystal form on the physicochemical properties of tofacitib citrate(1) in bulk forms were studied. Two kinds of 1 crystal(formⅠ and formⅡ) were prepared by solvent crystallization method. They were characterized by PXRD, DSC/TGA and FT-IR, and their particle size distribution, equilibrium solubility and fluidity were determined. The results showed that PXRD pattern and FT-IR spectrum of formⅠwere consistent with those reported in the original patent while the DSC/TGA curves were slightly different, but the PXRD pattern, FT-IR spectrum and DSC/TGA curves of form Ⅱ were significantly different from those of form Ⅰ. The equilibrium solubilities of formⅠ and form Ⅱshowed a significant pH dependence while the dissolution rate of form Ⅱ was significantly lower than that of form Ⅰ. In addition, the particle size of form Ⅱ was obviously larger than that of form Ⅰ, and the fluidity of form Ⅱ was better than that of form Ⅰ. This research indicated that the new crystal type(form Ⅱ) of 1 might have a good application prospect in the development of sustained-release preparations.

  • Ganggang WANG, Sijin WANG, Shihong MA
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 96-100.

    Three levels of concentration(0.85, 1.15, 3.08 cfu/mL) of Escherichia coli suspensions were used as objects, with 100 plates in each group for colony counting, which served as the data basis for simulating the data for different numbers of test plate combined with counting. The deviations between the reported results and the true values were analyzed under different conditions. Data of 3 groups followed Poisson distribution. For the same number of test plates,the RSD of plate counts decreased with the increasing of the concentration of bacterial suspension. For the same bacterial suspension, the RSD of plate counts and the range of reported results decreased with the increasing of the number of test plates. The lower concentration of bacterial suspension, the greater coefficient of dispersion, and the higher the risk of misjudgment. Increasing the number of test plates was beneficial to improve the accuracy of microbial count resulted in low bioburden test dilution. When the combined count of colonies was no less than 4 cfu and the RSD was no more than 50%,the colony count results could provide an accurate estimate of the bioburden of the sample solution.

  • Yajuan LI, Jingyan MO, Hongwei LU, Xiaoyan YU
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 101-108.

    The intelligent equipment for pretreatment of traditional Chinese medicines(TCM) before testing is the first application of the intelligent TCM testing technology in the TCM industry, which realizes the transformation of the pretreatment of TCM detection from manual to intelligent. The intelligent equipment is composed of five modules: feed storage system, comprehensive pretreatment system, oscillation system, discharge/ultrasonic system and condensation reflux system. By investigating the precisions of quantitative liquid filling, medium heating time and medium temperature, it was proved that the intelligent equipment could meet the using requirements. With Albiziae Flos as the representative medicines,the consistency of the results between the samples processed by this intelligent equipment and the manual processing was compared, and the time consumption of multiple batches of samples were tested. The results showed that the equipment could realize the intelligent sorting of TCM pretreatment, and the online automatic cleaning of the condensing tube.Moreover, the processing efficiency of multiple batches of TCM could be increased to 94.40%.

  • Xueke MENG, Yunyun YIN, Yinlin MA, Xuesong GUO, Xiaodong YANG
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 109-112.

    The aim of this study was to comprehensively investigate the online cleaning effectiveness,integrity, sterility, thermal penetration, and thermal stability of the containers for low pH viral inactivation. The cleaning effectiveness was demonstrated by investigating the indicators of the rinsing water samples after online cleaning; the sealing performance was verified by pressure holding experiments; the sterility, thermal penetration and thermal stability were proved through simulated filling of the culture medium and the process temperature control tests. The results showed that after cleaning, the visible particles, pH value, conductivity, bacterial endotoxin, microbial limit and protein absorbance all met the requirements. The pressure-holding test of the low pH virus inactivation container was qualified. And the simulated sterilization culture medium was placed at (24±1)℃ for 21 days for simulating the virus inactivation. During the examination period, the tank temperature was stable at (24.0±0.2)℃, indicating good sterility, thermal penetration and thermal stability. These results indicated that the containers for low pH viral inactivation met the production requirements and could ensure the reliability during the viral inactivation process. This study provided a reference for the validation of GMP and process requirements of the containers for low pH viral inactivation.

  • Meng YU, Sijin WANG, Xundi ZHANG, Shihong MA
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 113-124.
  • Jiaqiang WANG, Shanshan LI, Yan XIE, Lixian SHEN
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 125-129.
  • Ganggang WANG, Sijin WANG, Shihong MA
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 130-135.
  • Lingna ZHANG, Qingyu CHEN, Rongzhen HUANG, Jianlong YUAN
    Chinese Journal of Pharmaceuticals. 2025, 56(1): 136-141.
  • Tao ZHANG, Cong HUANG, Huiwen LIU, Weiyue LU
    Chinese Journal of Pharmaceuticals. 2024, 55(12): 1603-1611.

    Low-concentration atropine eyedrops, an ophthalmic formulation for delaying myopia of adolescents, has been widely recognized due to its clinical therapeutic effects. However, the commercialized atropine sulfate eyedrops, ophthalmic aqueous solution, have many problems, such as eye irritation caused by low pH value of the aqueous solution, poor stability of the preparations and poor patient compliance. In this review, the formulations and preparation processes of atropine sulfate ophthalmic preparations currently under development and on the market are summarized, the characteristics, advantages and disadvantages of various technical approaches for improving stability and compliance of atropine sulfate ophthalmic products are analyzed, hoping to provide some references for the optimization of atropine ophthalmic formulations.