Effect of the Number of Test Plates on the Accuracy of Low Microbial Counting Results of Pharmaceutical Products
收藏切换
Ganggang WANG, Sijin WANG, Shihong MA*
Chinese Journal of Pharmaceuticals | 2025, 56(1) : 96 - 100
Less
收藏切换
Chinese Journal of Pharmaceuticals | 2025, 56(1): 96-100
• Paper •
Effect of the Number of Test Plates on the Accuracy of Low Microbial Counting Results of Pharmaceutical Products
Full
Ganggang WANG, Sijin WANG, Shihong MA*
Affiliations
  • National Institutes for Food and Drug Control, Beijing 100050
Published: 2025-01-10 doi: 10.16522/j.cnki.cjph.2025.01.011
Outline
收藏切换

Three levels of concentration(0.85, 1.15, 3.08 cfu/mL) of Escherichia coli suspensions were used as objects, with 100 plates in each group for colony counting, which served as the data basis for simulating the data for different numbers of test plate combined with counting. The deviations between the reported results and the true values were analyzed under different conditions. Data of 3 groups followed Poisson distribution. For the same number of test plates,the RSD of plate counts decreased with the increasing of the concentration of bacterial suspension. For the same bacterial suspension, the RSD of plate counts and the range of reported results decreased with the increasing of the number of test plates. The lower concentration of bacterial suspension, the greater coefficient of dispersion, and the higher the risk of misjudgment. Increasing the number of test plates was beneficial to improve the accuracy of microbial count resulted in low bioburden test dilution. When the combined count of colonies was no less than 4 cfu and the RSD was no more than 50%,the colony count results could provide an accurate estimate of the bioburden of the sample solution.

plate count  /  Poisson distribution  /  microbial enumeration  /  microbial contaminant control
王杠杠, 王似锦, 马仕洪. 试验平皿数对药品低水平微生物计数结果准确性的影响. 中国医药工业杂志, 2025 , 56 (1) : 96 -100 . DOI: 10.16522/j.cnki.cjph.2025.01.011
Ganggang WANG, Sijin WANG, Shihong MA. Effect of the Number of Test Plates on the Accuracy of Low Microbial Counting Results of Pharmaceutical Products[J]. Chinese Journal of Pharmaceuticals, 2025 , 56 (1) : 96 -100 . DOI: 10.16522/j.cnki.cjph.2025.01.011
Year 2025 volume 56 Issue 1
47
15
Cite this Article
BibTeX
Article Info
doi: 10.16522/j.cnki.cjph.2025.01.011
  • Receive Date:2024-05-04
  • Online Date:2026-11-17
  • Published:2025-01-10
Article Data
Affiliations
History
  • Received:2024-05-04
Funding
Affiliations
    National Institutes for Food and Drug Control, Beijing 100050
References
Share
https://castjournals.cast.org.cn/joweb/zgyygy/EN/10.16522/j.cnki.cjph.2025.01.011
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT