收藏切换
Comparison of two methods for the determination of sucrose octasulfate concentration in irinotecan hydrochloride liposomes
收藏切换
PDF
Hui-jia WANG1, Yuan-jian WANG1, 2, Chen LIANG2, Qian CAI3, Hong-sheng XU4, Qing LI1, *
Acta Pharmaceutica Sinica | 2020, 55(3) : 501 - 505
Less
收藏切换
Acta Pharmaceutica Sinica | 2020, 55(3): 501-505
Original Articles
Comparison of two methods for the determination of sucrose octasulfate concentration in irinotecan hydrochloride liposomes
Full
Hui-jia WANG1, Yuan-jian WANG1, 2, Chen LIANG2, Qian CAI3, Hong-sheng XU4, Qing LI1, *
Affiliations
  • 1. School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, China
  • 2. Bostal Drug Delivery Co., Ltd., Guangzhou 510530, China
  • 3. Liaoyuan Food and Drug Administration, Liaoyuan 136200, China
  • 4. Zhejiang Shapuaisi Pharmaceutical Co., Ltd., Jiaxing 314200, China
Published: 2020-03-12 doi: 10.16438/j.0513-4870.2019-0638
Outline
收藏切换

HPLC-RID and HPIC-CD methods were established for the determination of sucrose octasulfate content in irinotecan hydrochloride liposomes for injection. HPLC-RID:This method was performed on a Kromasil 100-5-NH2 column (250 mm×4.6 mm, 5 μm) with a mobile phase of 0.8 mol·L-1 ammonium sulfate buffer (pH 3.5)-acetonitrile (83:17). The flow rate, column temperature and detector temperature were maintained at 1 mL·min-1, 30℃ and 30℃ respectively. HPIC-CD:This method was performed on an anion exchange column Dionex InPacTM AS11-HC (250 mm×4 mm, 9 μm) with an eluent of 30 mmol·L-1 sodium hydroxide solution. The flow rate was 1.5 mL·min-1, the column temperature was 30℃ and the detector temperature was 35℃. The HPLC-RID method and HPIC-CD method were validated with respects to specificity, limit of detection, limit of quantitation, linearity, precision, accuracy, stability and robustness and met the validation requirements. There were no significant differences between the HPIC-CD and HPLC-RID methods according to T-test analysis, both of which were applicable for the measurement of sucrose octasulfate concentration in irinotecan hydrochloride liposomes for injection. However, the HPLC-CD was better at the following aspects:higher detection sensitivity, simpler sample pretreatment, lower time and money spent, better environmental protection.

HPIC-CD  /  HPLC-RID  /  sucrose octasulfate  /  irinotecan hydrochloride  /  liposome
Hui-jia WANG, Yuan-jian WANG, Chen LIANG, Qian CAI, Hong-sheng XU, Qing LI. Comparison of two methods for the determination of sucrose octasulfate concentration in irinotecan hydrochloride liposomes[J]. Acta Pharmaceutica Sinica, 2020 , 55 (3) : 501 -505 . DOI: 10.16438/j.0513-4870.2019-0638
Year 2020 volume 55 Issue 3
PDF
138
55
Cite this Article
BibTeX
Article Info
doi: 10.16438/j.0513-4870.2019-0638
  • Receive Date:2019-08-31
  • Online Date:2026-01-20
  • Published:2020-03-12
Article Data
Affiliations
History
  • Received:2019-08-31
  • Revised:2019-11-30
Affiliations
    1. School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, China
    2. Bostal Drug Delivery Co., Ltd., Guangzhou 510530, China
    3. Liaoyuan Food and Drug Administration, Liaoyuan 136200, China
    4. Zhejiang Shapuaisi Pharmaceutical Co., Ltd., Jiaxing 314200, China
References
Share
https://castjournals.cast.org.cn/joweb/yxxb/EN/10.16438/j.0513-4870.2019-0638
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT