收藏切换
Simultaneous determination of aluminum trioxide,silicon dioxide,and magnesium oxide in montmorillonite raw materials and their formulations using secondary microwave digestion inductively coupled plasma mass spectrometry technology*
收藏切换
PDF
Zhen CHEN1, Jing XIE2, Feng SHI1, Rui-qing XIAN1, Li-ping GONG1, **, Bao-jian HANG1, Peng-fei YOU1, Xiao CHEN1, Dong-mei ZHANG1
Chinese Journal of Pharmaceutical Analysis | 2024, 44(4) : 577 - 584
Less
收藏切换
Chinese Journal of Pharmaceutical Analysis | 2024, 44(4): 577-584
Ingredient Analysis
Simultaneous determination of aluminum trioxide,silicon dioxide,and magnesium oxide in montmorillonite raw materials and their formulations using secondary microwave digestion inductively coupled plasma mass spectrometry technology*
Full
Zhen CHEN1, Jing XIE2, Feng SHI1, Rui-qing XIAN1, Li-ping GONG1, **, Bao-jian HANG1, Peng-fei YOU1, Xiao CHEN1, Dong-mei ZHANG1
Affiliations
  • 1.Shandong Institute for Food and Drug Control, Jinan 250101, China
  • 2.Qilu Hospital of Shandong University, Jinan 250063, China
Published: 2024-04-30 doi: 10.16155/j.0254-1793.2024.04.04
Outline
收藏切换
Objective:

To establish a method for simultaneous determination of aluminum trioxide, silicon dioxide and magnesium oxide in montmorillonite and its preparations.

Methods:

The method was optimized and established for simultaneous determination of aluminum (27Al), silicon (28Si), and magnesium (24Mg) in montmorillonite using rhadium (103Rh) as the internal standard, a dilute nitric acid hydrofluoric acid saturated boric acid solution with secondary microwave digestion and inductively coupled plasma mass spectrometry(ICP-MS). The method was compared and analyzed with the EDTA volumetric method for the determination of aluminum trioxide, the muffle ignition combustion method for the determination of silicon dioxide and the AAS method for the determination of magnesium oxide after melting samples of lithium metaborate in the USP.

Results:

The linear of aluminum (Al) and silicon (Si) were in the range of 25-300 ng·mL-1. The linear of magnesium (Mg) was in the range of 20-240 ng·mL-1, r≥0.999. The detection limits of Al, Si, and Mg were 0.49, 1.30, 0.71 ng·mL-1. The average recoveries were 99.7%-100.6%, 99.9%-101.2%, 99.8%-101.2%, and the average repeatability RSDs (n=6) were 0.3%-1.3%, 0.4%-1.2%, and 0.4%-1.0%. The contents of aluminum trioxide, silicon dioxide and magnesium oxide in montmorillonite, montmorillonite powder, and montmorillonite dispersion tablets were determined using the newly established method and the original standard method, and the measurement results were basically consistent. Eight common peaks were identified from fingerprints of 10 batches of samples. The RSD values of relative retention time of 8 common peaks of chromotograms of samples were all below 0.5% and the similarities were above 0.9. The contents of aluminum trioxide in montmorillonite were determined using the newly established method and the original standard method, which were 2.3% to 2.4%, 2.0% to 2.2%, 58.7% to 61.5%, 55.3% to 59.4%, and 15.9% to 20.6%, 14.6% to 19.4%, respectively. The results of the measurements were basically consistent for the determination of aluminum trioxide, silicon dioxide, and magnesium oxide content in montmorillonite raw materials and formulations.

Conclusion:

The newly established content determination method uses a combination of secondary microwave digestion and ICP-MS technology to determine the content of aluminum oxide, silicon dioxide, and magnesium oxide in montmorillonite samples. It is simple, fast, sensitive, and accurate, and can be used.

montmorillonite powder  /  montmorillonite dispersible tablets  /  aluminum trioxide  /  silicon dioxide  /  agnesium oxide  /  microwave digestion  /  inductively coupled plasma mass spectrometry
Zhen CHEN, Jing XIE, Feng SHI, Rui-qing XIAN, Li-ping GONG, Bao-jian HANG, Peng-fei YOU, Xiao CHEN, Dong-mei ZHANG. Simultaneous determination of aluminum trioxide,silicon dioxide,and magnesium oxide in montmorillonite raw materials and their formulations using secondary microwave digestion inductively coupled plasma mass spectrometry technology*[J]. Chinese Journal of Pharmaceutical Analysis, 2024 , 44 (4) : 577 -584 . DOI: 10.16155/j.0254-1793.2024.04.04
Year 2024 volume 44 Issue 4
PDF
80
33
Cite this Article
BibTeX
Article Info
doi: 10.16155/j.0254-1793.2024.04.04
  • Receive Date:2023-11-14
  • Online Date:2026-03-13
  • Published:2024-04-30
Article Data
Affiliations
History
  • Received:2023-11-14
Funding
Affiliations
    1.Shandong Institute for Food and Drug Control, Jinan 250101, China
    2.Qilu Hospital of Shandong University, Jinan 250063, China
References
Share
https://castjournals.cast.org.cn/joweb/ywfxzz/EN/10.16155/j.0254-1793.2024.04.04
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT