收藏切换
Determination of related substances and impurity profile in peramivir injection by HPLC-CAD
收藏切换
PDF
Si-meng FANG, Xi-yu DUAN, Yu-rong SUI, Xin LU, Xiao-jie HAN*, Hai-jiao BAI*
Chinese Journal of Pharmaceutical Analysis | 2024, 44(12) : 2105 - 2113
Less
收藏切换
Chinese Journal of Pharmaceutical Analysis | 2024, 44(12): 2105-2113
Safety Monitoring
Determination of related substances and impurity profile in peramivir injection by HPLC-CAD
Full
Si-meng FANG, Xi-yu DUAN, Yu-rong SUI, Xin LU, Xiao-jie HAN*, Hai-jiao BAI*
Affiliations
  • Tianjin Institute for Drug Control, Tianjin 300070, China
Published: 2024-12-31 doi: 10.16155/j.0254-1793.2024-0272
Outline
收藏切换
Objective:

To establish an HPLC-CAD method for the determination of related substances in peramivir injection and to analyze the impurity profile.

Methods:

Welch Ultimate Polar RP column (250 mm×4.6 mm, 3.5 μm) was used with 5 mmol·L-1 ammonium formate solution (pH adjusted to 4.6 with formic acid) -acetonitrile (95∶5) as mobile phase A and mobile phase A-acetonitrile (50∶50) as mobile phase B under gradient elution at the flow rate of 0.8 mL·min-1. Column temperature was 30 ℃. CAD atomizer temperature was 50 ℃, acquisition frequency was 5 Hz and filter was 3.6 s. The degradation pathway and impurity structure of peramivir were estimated by LC-MS/MS.

Results:

The separation between peramivir and the impurities was good. The mass concentration of peramivir and 7 impurities showed good linear relationships with the peak area in the ranges of 0.2-12 μg·mL-1. The limits of quantitation were 4.32-12.8 ng, and the limits of detection were 2.16-6.44 ng. The average recovery (n=9) of impurity Ⅲ was 96.2%, RSD was 1.8%. The control solution and the test product solution were stable for 102 hours at room temperature. After fine-tuning the parameters of liquid chromatography, there was no influence on the detection results of related substances. Based on LC-MS/MS, the structure and possible degradation pathway of the degraded related substances were deduced.

Conclusion:

This method is accurate, reliable and specific for the determination of related substances in peramivir injection, and provides a basis for the establishment of quality standards for this variety.

peramivir injection  /  HPLC  /  electrospray detector  /  impurity profile analysis  /  related substances
Si-meng FANG, Xi-yu DUAN, Yu-rong SUI, Xin LU, Xiao-jie HAN, Hai-jiao BAI. Determination of related substances and impurity profile in peramivir injection by HPLC-CAD[J]. Chinese Journal of Pharmaceutical Analysis, 2024 , 44 (12) : 2105 -2113 . DOI: 10.16155/j.0254-1793.2024-0272
Year 2024 volume 44 Issue 12
PDF
103
49
Cite this Article
BibTeX
Article Info
doi: 10.16155/j.0254-1793.2024-0272
  • Receive Date:2024-04-23
  • Online Date:2026-03-13
  • Published:2024-12-31
Article Data
Affiliations
History
  • Received:2024-04-23
Affiliations
    Tianjin Institute for Drug Control, Tianjin 300070, China
References
Share
https://castjournals.cast.org.cn/joweb/ywfxzz/EN/10.16155/j.0254-1793.2024-0272
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT