收藏切换
Rapid detection of aflatoxin B1 by electrochemiluminescence test strip method
收藏切换
Yuan-Di ZHANG, Hao LIU, Cheng-Yi XIONG, Xiu-Hua ZHANG, Miao-Miao CHEN*
Journal of Food Safety & Quality | 2026, 17(13) : 22 - 29
Less
收藏切换
Journal of Food Safety & Quality | 2026, 17(13): 22-29
• Special Topic: Detection and Prevention and Control of Biotoxins in Food •
Rapid detection of aflatoxin B1 by electrochemiluminescence test strip method
Full
Yuan-Di ZHANG, Hao LIU, Cheng-Yi XIONG, Xiu-Hua ZHANG, Miao-Miao CHEN*
Affiliations
  • College of Chemistry and Chemical Engineering, Food Safety Research Institute, Hubei University, Wuhan 430062, China
doi: 10.19812/j.cnki.jfsq11-5956/ts.20260519005
Outline
收藏切换
Objective

To develop an electrochemiluminescence (ECL) test strip for the detection of aflatoxin B1(AFB1).

Methods

The ECL test strip was fabricated by patterning carbon ink electrode onto the surface of a polyvinyl chloride substrate and then assembling them with a lateral flow immunoassay strip. The electrochemical performance of the ECL test strip was investigated using cyclic voltammetry. Meanwhile, Ru-PEI/Ti3C2Tx@Au composites were synthesized and conjugated with AFB1 monoclonal antibodies (Anti-AFB1) to serve as ECL signal probes. Through the competitive immunoreaction between the AFB1-bovine serum albumin conjugate immobilized on the test line of the ECL test strip and the ECL signal probes, colorimetric and ECL signals were obtained.

Results

The fabricated ECL test strips exhibited good stability and specificity. Under optimal conditions, the colorimetric signal showed a good linear relationship with the logarithm of AFB1 concentration in the range from 0.1 ng/mL to 100.0 ng/mL, with a limit of detection of 32 pg/mL. In addition, the ECL signal showed a good linear relationship with the logarithm of AFB1 concentration in the range from 1.0 pg/mL to 100.0 ng/mL, with a limit of detection of 319 fg/mL. Furthermore, satisfactory recovery rates ranging from 92.6% to 110.3% were achieved by the proposed ECL test strips, along with relative standard deviations of 0.9% to 6.2%.

Conclusion

The developed ECL test strip enables highly sensitive and rapid detection of AFB1 in corn samples, providing a new perspective for rapid mycotoxin detection.

aflatoxin B1  /  electrochemiluminescence test strip  /  biosensing  /  rapid detection
张媛狄, 刘豪, 熊成义, 张修华, 陈苗苗. 电化学发光试纸条法快速检测黄曲霉毒素B1. 食品安全质量检测学报, 2026 , 17 (13) : 22 -29 . DOI: 10.19812/j.cnki.jfsq11-5956/ts.20260519005
Yuan-Di ZHANG, Hao LIU, Cheng-Yi XIONG, Xiu-Hua ZHANG, Miao-Miao CHEN. Rapid detection of aflatoxin B1 by electrochemiluminescence test strip method[J]. Journal of Food Safety & Quality, 2026 , 17 (13) : 22 -29 . DOI: 10.19812/j.cnki.jfsq11-5956/ts.20260519005
Year 2026 volume 17 Issue 13
13
3
Cite this Article
BibTeX
Article Info
doi: 10.19812/j.cnki.jfsq11-5956/ts.20260519005
  • Receive Date:2026-05-19
  • Online Date:2026-11-05
Article Data
Affiliations
History
  • Received:2026-05-19
Funding
Affiliations
    College of Chemistry and Chemical Engineering, Food Safety Research Institute, Hubei University, Wuhan 430062, China
References
Share
https://castjournals.cast.org.cn/joweb/spaq/EN/10.19812/j.cnki.jfsq11-5956/ts.20260519005
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT