收藏切换
Ground Calibration Method for the Chang’E-7 Lunar Microwave Imaging Radar
收藏切换
PDF
Haixia YUE, Yu WANG, Pei WANG, Yuanbo JIAO, Yi HUANG, Zhipeng LÜ
Chinese Journal of Space Science | 2026, 46(2) : 531 - 539
Less
收藏切换
Chinese Journal of Space Science | 2026, 46(2): 531-539
Calibration for the Payload of Chang’E-7 Mission
Ground Calibration Method for the Chang’E-7 Lunar Microwave Imaging Radar
Full
Haixia YUE, Yu WANG, Pei WANG, Yuanbo JIAO, Yi HUANG, Zhipeng LÜ
Affiliations
  • Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190
Published: 2026-03-15 doi: 10.11728/cjss2026.02.2025-0119
Outline
收藏切换

After the Chang’E-7 lunar microwave imaging radar in the fourth phase of the Lunar Exploration Project is put into on-orbit operation in the future, calibration devices will not be deployed on the lunar surface, making on-orbit External calibration impossible. To ensure the acquisition of high-precision lunar surface image data, a ground calibration method is proposed. This method combines the internal calibration of the radar system with the performance calibration in the inner field. During ground testing, the internal calibration accuracy and the consistency of internal calibration channels are obtained by measuring the temperature characteristics of the internal calibration network under a full-temperature environment. The internal calibration constants are acquired in an anechoic chamber. By constructing a wireless transceiver environment in the inner field with the help of the anechoic chamber, the absolute transceiver gains and the stability of the transceiver channels of the system are accurately calibrated. The basic data obtained through ground calibration can be used for the calibration of indicators such as on-orbit internal calibration constants, absolute and relative radiation accuracy, and polarization channel consistency, providing guarantee for high-resolution lunar surface exploration.

Synthetic Aperture Radar (SAR)  /  Internal calibration  /  Ground calibration  /  Channel calibration
Haixia YUE, Yu WANG, Pei WANG, Yuanbo JIAO, Yi HUANG, Zhipeng LÜ. Ground Calibration Method for the Chang’E-7 Lunar Microwave Imaging Radar[J]. Chinese Journal of Space Science, 2026 , 46 (2) : 531 -539 . DOI: 10.11728/cjss2026.02.2025-0119
Year 2026 volume 46 Issue 2
PDF
110
45
Cite this Article
BibTeX
Article Info
doi: 10.11728/cjss2026.02.2025-0119
  • Receive Date:2025-07-15
  • Online Date:2026-07-08
  • Published:2026-03-15
Article Data
Affiliations
History
  • Received:2025-07-15
  • Revised:2025-11-27
Affiliations
    Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190
References
Share
https://castjournals.cast.org.cn/joweb/kjkxxb/EN/10.11728/cjss2026.02.2025-0119
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT