收藏切换
Optimized design on insulation structure of post insulators for AC GIS
收藏切换
PDF
Chaofeng LIU, Chuanyun ZHU, Jianbin LI, Ying CHEN, Xin HUANG, Xiaohu QI, Yongqing WANG, Jian GUAN, Xiyang JIN
Insulating Materials | 2024, 57(8) : 92 - 99
Less
收藏切换
Insulating Materials | 2024, 57(8): 92-99
Insulation Technology
Optimized design on insulation structure of post insulators for AC GIS
Full
Chaofeng LIU, Chuanyun ZHU, Jianbin LI, Ying CHEN, Xin HUANG, Xiaohu QI, Yongqing WANG, Jian GUAN, Xiyang JIN
Affiliations
  • Henan Pinggao Electric Co., Ltd., Pingdingshan 467001, China
Published: 2024-08-20 doi: 10.16790/j.cnki.1009-9239.im.2024.08.011
Outline
收藏切换

Post insulator is an important supporting component in gas insulated metal enclosed switchgear (GIS), its insulating properties affects the reliability and stability of GIS. Taking the post insulator for engineering GIS as research object, we selected the surface tangential electric field strength of the insulator as the insulating properties index, and analyzed the influence of the umbrella skirts number, starting position, root radius, top radius parameters of the insulator as well as the shrinkage umbrella skirt structure on the insulating properties. The results show that the tangential electric field of insulator shows wave peaks and troughs oscillation distribution by increasing the umbrella skirt number, which is conducive to hinder the development of insulator surface discharge. The maximum tangential electric field strength increases with the increase of umbrella skirts number, and decreases with the increase of the distance between the starting position of umbrella skirt and the high-voltage electrode. The location of the maximum tangential electric field value shifts with the radius at the base of umbrella skirt. Compared with the original structure, the maximum tangential electric field strength along the surface of optimized structure decreases from 12.66 kV/mm to 9.69 kV/mm, and the decrease rate is 23.5%. It is found that the insulation margin is more than 1.3 times through the negative lightning impulse voltage test and margin test.

post insulators  /  tangential electric field strength  /  surface flashover  /  structural optimization  /  lightning impulse voltage
Chaofeng LIU, Chuanyun ZHU, Jianbin LI, Ying CHEN, Xin HUANG, Xiaohu QI, Yongqing WANG, Jian GUAN, Xiyang JIN. Optimized design on insulation structure of post insulators for AC GIS[J]. Insulating Materials, 2024 , 57 (8) : 92 -99 . DOI: 10.16790/j.cnki.1009-9239.im.2024.08.011
Year 2024 volume 57 Issue 8
PDF
139
65
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2024.08.011
  • Receive Date:2023-09-13
  • Online Date:2025-12-24
  • Published:2024-08-20
Article Data
Affiliations
History
  • Received:2023-09-13
  • Revised:2023-11-10
Funding
Affiliations
    Henan Pinggao Electric Co., Ltd., Pingdingshan 467001, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2024.08.011
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT