收藏切换
Influence analysis of layered subsoil on vibration characteristics of balance foundation in the pulse wind tunnel
收藏切换
PDF
Baolong ZHU1, Kai LI1, Qi LIN2, Shien YU2
Earthquake Engineering and Engineering Dynamics | 2024, 44(6) : 125 - 137
Less
收藏切换
Earthquake Engineering and Engineering Dynamics | 2024, 44(6): 125-137
Influence analysis of layered subsoil on vibration characteristics of balance foundation in the pulse wind tunnel
Full
Baolong ZHU1, Kai LI1, Qi LIN2, Shien YU2
Affiliations
  • 1.School of Civil Engineering and Architecture, Southwest University of Science and Technology, Mianyang 621010, China
  • 2.China Aerodynamics Research and Development Center, Mianyang 621000, China
doi: 10.13197/j.eeed.2024.0612
Outline
收藏切换

Since the pulsed wind tunnel balance foundation plays a supporting role in aircraft wind tunnel tests, in order to deeply study the influence of the layered subsoil on the vibration characteristics of the balance foundation, the impedance function of the balance foundation on a layered subsoil under impulse load is derived. A dynamic response equation of the foundation is established by using a simplified model, and the dynamic impedance function of the simplified model is equated with that of the foundation-foundation system. The dynamic response of the balance foundation on the laminated foundation under impulsive wind tunnel loading is obtained and verified by numerical simulation. The results show that the vertical amplitude, horizontal amplitude and slewing angle of the foundation gradually decrease with the increase of the loading frequency. The increase of the loading amplitude leads to the increase of the maximum amplitude of foundation vibration, while the vibration frequency remains unchanged. The increase of the shear modulus of the foundation results in the decreasing of the maximum amplitude of foundation vibration. The increase of the foundation dimensions leads to the obvious decreasing of the maximum amplitude of foundation vibration and the vibration frequency. In addition, the vertical vibration amplitude of the foundation increases with the decrease of foundation layer depth ratio, while the horizontal vibration amplitude and slewing angle decrease with the decrease of layer depth ratio. The increase of foundation shear wave velocity has less effect on the vertical vibration amplitude, while the effect on the horizontal vibration amplitude and slewing angle is more significant.

pulse wind tunnel  /  layered subsoil  /  balance foundation  /  vibration characteristics  /  impedance function
Baolong ZHU, Kai LI, Qi LIN, Shien YU. Influence analysis of layered subsoil on vibration characteristics of balance foundation in the pulse wind tunnel[J]. Earthquake Engineering and Engineering Dynamics, 2024 , 44 (6) : 125 -137 . DOI: 10.13197/j.eeed.2024.0612
Year 2024 volume 44 Issue 6
PDF
61
34
Cite this Article
BibTeX
Article Info
doi: 10.13197/j.eeed.2024.0612
  • Receive Date:2023-10-08
  • Online Date:2026-03-30
Article Data
Affiliations
History
  • Received:2023-10-08
  • Revised:2023-11-22
Funding
Affiliations
    1.School of Civil Engineering and Architecture, Southwest University of Science and Technology, Mianyang 621010, China
    2.China Aerodynamics Research and Development Center, Mianyang 621000, China
References
Share
https://castjournals.cast.org.cn/joweb/dzgcygczd/EN/10.13197/j.eeed.2024.0612
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT