收藏切换
Seismic responses control of inter-story isolated multi-tower structure with a large chassis
收藏切换
PDF
Qianmin LIU, Qisong MIAO, Dongdong GE, Xi CHEN
Earthquake Engineering and Engineering Dynamics | 2024, 44(4) : 148 - 156
Less
收藏切换
Earthquake Engineering and Engineering Dynamics | 2024, 44(4): 148-156
Seismic responses control of inter-story isolated multi-tower structure with a large chassis
Full
Qianmin LIU, Qisong MIAO, Dongdong GE, Xi CHEN
Affiliations
  • Beijing Institute of Architectural Design Co, Ltd, Beijing 100045, China
doi: 10.13197/j.eeed.2024.0414
Outline
收藏切换

Study the influence of different seismic response control methods on the seismic performance of inter-story isolated multi-tower structure with a large chassis, identify the advantages of different methods in improving the seismic performance, and then provide reference for the seismic response control of such structures. Three control schemes were designed based on a real engineering practice of such building, including adding viscous fluid dampers in the isolation system, adding viscous fluid dampers in the large chassis, and increasing the stiffness of the large chassis. The elastic-plastic finite element models of three control schemes and the prototype structure were established by using the Perform-3D. The seismic responses of these four structures were analyzed and compared, and the control effects of three control schemes on the seismic responses were identified. The following conclusions are drawn that introducing viscous dampers to isolation system is an optimal scheme for controlling the displacement of isolation system and floor acceleration of large chassis, but it significantly increased the seismic responses of tower. The control effects of increasing the stiffness of large chassis on the inter-story drift ratio of large chassis, as well as on the inter-story drift ratio and floor acceleration of tower are the best. All three schemes have negligible control effects on the inter-story drift ratio of tower.

inter-story isolated multi-tower structure with a large chassis  /  viscous damper  /  stiffness  /  seismic response
Qianmin LIU, Qisong MIAO, Dongdong GE, Xi CHEN. Seismic responses control of inter-story isolated multi-tower structure with a large chassis[J]. Earthquake Engineering and Engineering Dynamics, 2024 , 44 (4) : 148 -156 . DOI: 10.13197/j.eeed.2024.0414
Year 2024 volume 44 Issue 4
PDF
75
41
Cite this Article
BibTeX
Article Info
doi: 10.13197/j.eeed.2024.0414
  • Receive Date:2023-10-10
  • Online Date:2026-03-30
Article Data
Affiliations
History
  • Received:2023-10-10
  • Revised:2024-03-26
Funding
Affiliations
    Beijing Institute of Architectural Design Co, Ltd, Beijing 100045, China
References
Share
https://castjournals.cast.org.cn/joweb/dzgcygczd/EN/10.13197/j.eeed.2024.0414
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT