收藏切换
Analysis of seismic response of single-tube with two-track shield tunnels considering prefabricated internal structures
收藏切换
PDF
Zeren TANG1, Chen CHEN2, Yuanchang ZHU1, Yanan DU2, Xian LIU1
Earthquake Engineering and Engineering Dynamics | 2025, 45(3) : 85 - 95
Less
收藏切换
Earthquake Engineering and Engineering Dynamics | 2025, 45(3): 85-95
Analysis of seismic response of single-tube with two-track shield tunnels considering prefabricated internal structures
Full
Zeren TANG1, Chen CHEN2, Yuanchang ZHU1, Yanan DU2, Xian LIU1
Affiliations
  • 1.College of Civil Engineering, Tongji University, Shanghai 200092, China
  • 2.China Railway 14th Bureau Group Shield Engineering Co., Ltd., Nanjing 211800, China
Published: 2025-06-30 doi: 10.13197/j.eeed.2025.0307
Outline
收藏切换

To investigate the seismic response of single-hole with two-track shield tunnels and inside prefabricated internal structures, this paper adopts stratum-structure method and viscous-spring artificial boundaries, utilizing the concrete damage plasticity (CDP) model to structures and establish the finite element models based on the Shanghai airport link line. After simulating, analyzing, and comparing, the seismic response of single-hole with two-track shield tunnels under five earthquakes has obtained. The results reveal that: internal structures, which can effectively increase the lateral stiffness of tunnel and reduce the diameter deformation rate, are beneficial to the seismic performance of tunnel. However, due to the internal structures, the most severely damaged part of the tunnel will change. Although the under-track structure increases the transverse stiffness of tunnel, the side walls on both sides of middle box culvert will be the first damaged parts under seismic wave. The seismic performance of partition walls is the worst among all components, and its response is controlled by the medium to long periods of seismic wave. Damage to the middle partition wall is mainly concentrated on the top and bottom. The seismic performance of the tunnel structure is relatively good, while the seismic performance of the internal structure is relatively poor, especially the middle partition wall. Future design and research should focus on the partition walls.

seismic response  /  single-tube with two-tracks shield tunnel  /  prefabricated internal structure  /  under-track structure  /  partition wall
Zeren TANG, Chen CHEN, Yuanchang ZHU, Yanan DU, Xian LIU. Analysis of seismic response of single-tube with two-track shield tunnels considering prefabricated internal structures[J]. Earthquake Engineering and Engineering Dynamics, 2025 , 45 (3) : 85 -95 . DOI: 10.13197/j.eeed.2025.0307
Year 2025 volume 45 Issue 3
PDF
66
35
Cite this Article
BibTeX
Article Info
doi: 10.13197/j.eeed.2025.0307
  • Receive Date:2024-06-30
  • Online Date:2026-03-20
  • Published:2025-06-30
Article Data
Affiliations
History
  • Received:2024-06-30
  • Revised:2024-09-08
Funding
Affiliations
    1.College of Civil Engineering, Tongji University, Shanghai 200092, China
    2.China Railway 14th Bureau Group Shield Engineering Co., Ltd., Nanjing 211800, China
References
Share
https://castjournals.cast.org.cn/joweb/dzgcygczd/EN/10.13197/j.eeed.2025.0307
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT