Home Latest Articles
Latest Articles
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 183-192,212.
    To address the issues of complex equipment, high energy consumption and poor durability in the treatment process of biogas and biogas slurry during anaerobic fermentation of biomass, a new type of integrated ammonia recovery and carbon capture device was designed based on superamphiphobic membrane contactor, which integrated the advantages of direct contact membrane distillation, membrane absorption and other technologies. This device effectively enhances the energy utilization efficiency of the overall process while reducing the complexity of the equipment. The ammonia recovery and carbon capture performances of the integrated device was systematically studied through experiments. Results show that when using ammonia of low surface tension as feed side, the droplet contact angle of membrane contactor is greater than 150°, and maintains stable operation within 48 h. When operating with a gas circulation process flow and the temperature on the feed liquid side reaches 70 ℃, the ammonia recovery rate of the integrated device is increased from 45% to 97%, and the CO2 removal rate exceeds 95%, the CO2 removal rate on the permeate side can reach above 4.3 mol/(m2·h), thus realizing the high-efficiency resource utilization of wastes in the biogas slurry and biogas treatment processes.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 202-212.
    Due to the urgent need for a method that can objectively reflect the energy efficiency evaluation of novel power systems, based on the viewpoint of systems engineering and a thermo-economic state equation for modern power systems ,the steam-water distribution state equation of the system and general equations for transfer and analysis of output work and cycle heat absorption were constructed, corresponding one-to-one with the structure of the power plant's thermal system. Based on this, carbon capture, energy storage, wind power, photovoltaics, and solar thermal power were treated as auxiliary systems to explore their integration mechanisms with the thermal system of the thermal power units. A novel wind-solar-fire-storage complementary hybrid power generation system considering carbon capture system was proposed, and a general equation for energy efficiency evaluation and calculation of the multi-energy complementary hybrid power generation system was established. Finally, the proposed method was verified through a case study. Results show that the method possesses the characteristics of being universal, precise, and programmable, which makes the overall calculation and local analysis of the complex system energy efficiency clearer, providing theoretical support for the energy efficiency evaluation of clean and low-carbon novel power systems.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 193-201.
    With the widespread application of renewable energy, the operational complexity and uncertainty of integrated energy systems have increased significantly. Traditional scheduling methods are insufficient to efficiently address issues such as multi-energy flows and strong coupling. Therefore, an integrated energy system model encompassing photovoltaic panels, wind turbines, hydrogen storage tanks, batteries, heat pumps, and fuel cells was developed. By combining the deep deterministic policy gradient (DDPG) algorithm, the energy scheduling optimization under uncertain conditions was achieved. Results show that the DDPG algorithm can effectively solve the problem of multi-energy flow coordinated scheduling, achieving supply-demand balance and efficient utilization of electricity, heat, cooling, and hydrogen under different load demands and energy supply conditions. Moreover, after training, the system exhibits excellent scheduling performance and adaptability when confronted with diverse uncertain scenarios, enabling flexible responses to energy fluctuations.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 174-182.
    To enhance the prediction accuracy of SO2 emissions during sludge incineration process and optimize incineration and flue gas treatment conditions, an efficient and stable hybrid prediction model for SO2 emissions was prorosed. First, using a bubbling fluidized bed sludge incineration system as the research subject, static and dynamic flame features were extracted from flame images and the input features were set combined with distributed control system (DCS) parameters, while SO2 emission concentration was set as the model output. Subsequently, mutual information (MI) was employed to determine the optimal lag time between SO2 and each input feature, guiding data reorganization. Finally, the extremely randomized trees (ERT) model based on Bayesian optimization-TPE (BO-TPE) was constructed and compared with multiple mainstream prediction models. Results show that the BO-TPE-optimized ERT model achieves correlation coefficient R2 of 0.93 with mean absolute percentage error(MAPE) below 3%, making it suitable for online prediction and process optimization control of SO2 emissions in sludge incineration systems.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 164-173.
    The traditional Riccati transfer matrix method exhitibs significant limitations in accurately reflecting the dynamic characteristics of steam turbine rotors under fault scenarios. Additionally, the identification of critical sections primarily relies on alternating stress amplitude, while neglecting the impact of non-zero mean stress, which may lead to deviations in fatigue damage estimation. An improved method was proposed, in which the steady-state motion parameters before the fault was taken as initial values.A three-point interpolation method was then employed to calculate the motion state of each shaft segment during the non-steady interval in real time, thereby capturing the true response when the fault was detected. Meanwhile, the fatigue damage was refined by incorporating the mean-stress effect based on Goodman's theory.A 600 MW steam turbine generator shafting was analyzed as an example to evaluate the fatigue damage caused by two types of resonance in the subsynchronous frequency range. Results show that the improved response calculation method significantly reduces errors caused by unsteady factors, and the identification of critical sections requires comprehensive consideration of the components and intensity of SSO excitation.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 157-163.
    A deterioration trend perception algorithm considering the operating characteristics of wind turbines was proposed. Firstly, a kinetic deterioration state indicator based on damage accumulation theory was proposed, and the bearing deterioration level (DL) was calculated by Hertz theory. Secondly, a hybrid long short-term memory (LSTM)-CatBoost predictor (HLCP) deterioration prediction method was proposed. The deterioration growth value was predicted by considering the influence of wind turbine operating characteristics and introducing the bearing speed as a time series input. Then, the critical value of bearing damage was calculated based on the simulation model, so as to predict the remaining bearing life. Finally, it was validated using the vibration and supervisory control and data acquisition (SCADA) data from a wind farm in the north of China. Results show that the proposed deterioration state indicator has a similarity of about 74.42% in predicting trend and historical trend, with obvious trend and monotonicity. The error between the remaining life prediction results obtained based on the HLCP model and the actual failure time is only 640 h, which is 16 461 h less compared to the prediction method that does not take into account the turbine's operating characteristics.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 146-156.
    To address issues of feature redundancy, low prediction accuracy, weak generalization ability, and high false alarm rates in existing gearbox fault warning methods, a fault warning method based on neural basis expansion analysis was proposed. The method combined Sigmoid growth curve with a density-based spatial clustering algorithm to extract normal monitoring data from raw data. An improved grey relational analysis algorithm was used to assign weights to different data points, variable information was deeply explored. Feature variables related to the oil temperature of the gearbox were extracted from the data collected by the high-dimensional monitoring and data acquisition system. Local nonlinear projection was used to decompose the target signal into basis functions to predict the state variables of the gearbox accurately, fault thresholds were set by sliding window and confidence interval to reduce the false alarm rate. The method was verified based on actual wind field data. Results show that the fault prediction method based on the NBEATSx model significantly improves the prediction accuracy in the state prediction of gearboxes, reduces the false alarm rate compared to traditional models, and has the ability to predict faults several hours in advance, thereby effectively ensuring the stable operation of wind turbine units.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 139-145.
    To understand the effect of alkali and alkaline earth metals on the gasification reactivity of biomass char under pressurized conditions, the biomass char prepared by pyrolysis at 800 ℃ was used as the research object. The pyrolyzed biomass was pre-treated with deionized water and dilute hydrochloric acid solution, respectively. Gasification study was conducted on the raw biomass char and the two pre-treated samples in a wire-mesh pressurized reactor under various gasification agents, temperatures, and pressures. Results show that most of the potassium and some of the calcium and magnesium can be removed from the water-washed samples, while no alkali and alkaline earth metals are detected in the acid-washed biomass char sample. At 850 ℃, the gasification reactivity is not affected by pressure, whereas at 1 000 ℃, pressure has a promotional effect on gasification reactivity. Water-soluble potassium and calcium significantly enhance the gasification reactivity with both CO2 and steam, and their catalytic effects are enhanced at high temperatures. The water-insoluble calcium only slightly increases the gasification reactivity. At 850 ℃, the reaction orders with respect to CO2 partial pressure are close to 0 for all samples, while at 1 000 ℃, the reaction order is greater than 0.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 133-138.
    Based on the acoustic-structural coupling method, the modal characteristics of a molten salt storage tank in a commercial 50 MW tower-type concentrated solar power (CSP) plant were simulated. The influence of anchoring methods on the sloshing characteristics of molten salt storage tanks under full liquid level conditions was investigated, and the effects of parameters such as different liquid levels and operating temperatures on the modal frequencies of unanchored molten salt storage tanks were explored. Results show that the first three orders of unanchored molten salt storage tanks under full liquid level are prone to rigid-body displacement modes, and the sloshing frequency values of the 3rd to 20th orders differ significantly from those of anchored tanks. Therefore, the unanchored configuration is more suitable for modal analysis of molten salt storage tanks. The sloshing frequency of the tank increases with the rise of liquid level under different liquid level conditions, and the sloshing frequency of each order is lower than the natural frequency of the empty tank. The natural vibration period of the empty tank ranges from 0.06-0.1 s, while the sloshing period is as long as 2-15 s, indicating that the sloshing frequency of the tank in the salt-filled state is highly susceptible to resonance under the excitation of long-period seismic waves. Operating temperature has little effect on the sloshing frequency of molten salt, but preheating temperature has a significant impact on the natural frequency of the empty tank. When the operating temperature increases by 100 K, the highest-order natural frequency of the empty tank only decreases by 2.5%. To avoid instability of large-capacity molten salt tanks under the action of high-frequency seismic waves in the preheated state, the influence of preheating temperature on the frequency of empty tanks should be taken into account in the seismic design of molten salt tank structures in practical engineering.
  • Journal of Chinese Society of Power Engineering. 2026, 46(2): 123-132.
    In order to study the performance characteristics of transcritical compressed carbon dioxide energy storage (TC-CCES) system and supercritical compressed carbon dioxide energy storage (SC-CCES) system with the same stages, a compressed carbon dioxide energy storage (CCES) system model based on Brayton cycle was established by Matlab software, the thermodynamic performance and exergy destruction distribution of the system were analyzed, and sensitivity analysis was carried out. Results show that under the design conditions, the cycle efficiency,exergy efficiency and energy storage density of SC-CCES system are 66.78%, 58.43% and 255.63 kW·h/m3 respectively, and those of TC-CCES system are 61.21%, 54.30% and 545.69 kW·h/m3 respectively. Exergy destruction analysis shows that improvement of the heat exchanger performance effectively improves the exergy efficiency of both systems. Increasing the energy storage pressure and energy release pressure and making the ambient temperature close to the critical temperature of CO2, the cycle efficiency and exergy destruction of both systems will increase, while decreasing the water temperature of interstage cooler can improve the performance of TC-CCES system, but it can't have much effect on SC-CCES system. Under the conditions of two-stage of compression and two-stage of expansion, SC-CCES system has better cycle efficiency and exergy efficiency, while the energy storage density of TC-CCES system is about twice that of SC-CCES system.