Home Latest Articles
Latest Articles
  • Meng WANG, Wei TIAN, Yaqin ZHEN, Lingfang WU, Junshan LI, Liying NIU
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1027-1033.

    An ultra-high performance liquid chromatography-mass spectrometry(UHPLC-MS/MS) method was established for the simultaneous determination of fourteen active ingredients, including neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, caffeic acid, isochlorogenic acid A, rutin, cynaroside, isoquercitrin, rosmarinic acid, diosmin, ferulic acid, scutellarin, luteolin-7-O-β-D-glucuronide and linarin, in Herba Micromeriae biflorae(1). The Acquity UPLC BEH C18 column(2.1 mm×100 mm, 1.7 μm) was used, and the analysis was carried out in the linear gradient elution mode with acetonitrile as mobile phase A and 0.1% formic acid solution as mobile phase B. The flow rate was 0.4 ml/min, the column temperature was 35 ℃ and the injection volume was 2 μl. The electron spray ionization(ESI) and multiple reaction monitoring(MRM) mode were used, and combined with cluster analysis, principal component analysis and orthogonal partial least squares-discriminant analysis to evaluate the differences of different batches of 1. The results showed that the linear relationship, precision, stability, repeatability and sample recovery of the fourteen compounds were all met the requirements. The chemometric analysis results showed that there were certain differences of the fourteen compounds in 1 from two origins in Yunnan and Sichuan, among which rosmarinic acid and linarin were the main differential components. The established UHPLC-MS/MS method is accurate, rapid, simple and highly sensitive, which provides a reference for the quality control of 1.

  • Guizhou HAO, Xiaojie CHEN, Jianhe SUN, Jipeng HOU, Zhong FENG, Guimin ZHANG
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1034-1037.

    An ultra-high performance liquid chromatography-mass spectrometry(UPLC-MS) method was established for the determination of migration quantity of hexadecanamide(2), oleamide(3) and stearamide(4) from butyl rubber stopper for injection of epirubicin hydrochloride. The Thermo Hypersil GOLD column(2.1 mm×100 mm,3 μm) was used, and the analysis was carried out in the isocratic elution mode with 0.1% formic acid solution∶methanol(15∶85) as the mobile phase. Electrospray ionization(ESI), positive ion mode acquisition and single ion detection mode (SIM) were used. The results showed that it was linear for 2, 3 and 4 in the ranges of 0.039 2 -0.783 6 μg/ml, 0.040 0 - 0.800 2 μg/ml and 0.037 3 - 0.746 0 μg/ml, respectively. The detection limits of 2, 3 and 4 were 0.011 8, 0.012 0, and 0.011 2 μg/ml, respectively, the mean recoveries(n=12) were 96.28%, 97.21%, and 94.11%, with the RSDs of 3.39%, 4.22%, and 5.63%, respectively. The established method has high sensitivity and good specificity, which provides a reference for the quality control and safety evaluation of epirubicin hydrochloride for injection.

  • Zhifeng CAO, Lipin ZHAO, Ting HE, Baijun MA
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1038-1042.

    Based on the same formula and process, the three-layer co-extrusion infusion films were prepared with domestic polypropylene(RPB05F middle-layer film material) or imported polypropylene as middle-layer granules, and their properties were compared. The results showed that there was basically no difference between the films prepared from domestic and imported polypropylene granules, and their physical, chemical and biological properties were all met the standards. In addition, the film made by domestic polypropylene granules also had good stability, and the performance did not significantly change during the investigation period. In the extraction test, the contents of antioxidants and metal elements were far less than the limits. The results indicated that domestic polypropylene granules could be applied to the production of three-layer co-extrusion infusion film.

  • Hai WANG, Feng SHEN
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1043-1048.

    Purified water is very important and widely used in pharmaceutical production as process water, which is crucial for the drug safety. The internationally recognized and generally accepted purified water treatment process,"reverse osmosis" system, was adopted as the model, and the concentrations of several chemical solutions were calculated, such as sodium hypochlorite(NaClO) solution, sodium bisulfite(NaHSO3) solution and sodium hydroxide(NaOH) solution, which must be added in the treatment process to ensure the quality of purified water for pharmaceutical use. From a scientific point of view, the reasons for adding of above chemical solutions were explained, and the concentrations and adding amounts were determined based on the determination results of free chlorine residual and pH values by quantitative analysis method, for guiding the operation procedure of purified water generation.

  • Ruoxi YAN
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1049-1055.
  • Baomei ZHANG, Xiaojun LU
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1056-1061.
  • Shuangfeng LOU, Hui CAO, Chuang ZHANG
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1062-1065.
  • Minghui SONG, Ning ZHANG, Feng QIN, Yulan JIN, Meicheng YANG
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1066-1070.
  • Yang LI, Shaoting CHENG, Ming XU
    Chinese Journal of Pharmaceuticals. 2022, 53(7): 1071-1074.
  • Gangsheng CHEN, Heng GUO, Fuli ZHANG
    Chinese Journal of Pharmaceuticals. 2022, 53(6): 763-774.

    The oral anti-COVID-19 agent, S-217622, developed by Shionogi & Co., Ltd., was proved to be well tolerated and effective for Omicron variant in phase Ⅱ clinical trial. And a phase Ⅲ clinical trial is currently underway. The synthesis of S-217622 consists of four fragments according to the retrosynthetic analysis method and the synthetic routes of each fragment and S-217622 are summarized in this paper.

News