Latest ArticlesIn the study, salbutamol sulfate was taken as a model drug, by replacing test actuators B and C with similar material, connecting valve stem and spray orifice structure to the reference actuator A, several critical quality attributes of metered-dose inhaler, namely aerodynamic particle size distribution(APSD), delivered dose(DD), spray pattern(SP), plume geometry(PG), were determined and compared. At the same time, the fine particle dose(FPD), median mass aerodynamic diameter(MMAD), geometric standard deviation(GSD), DD, ellipse ratio, spray area, plume angle, and plume width were used as the main investigation indexes, the subjective-objective combination weight assignment method was used to set the weight of each index, and the grey relation analysis(GRA) was combined to comprehensively evaluate the multiple indexes. In the comprehensive evaluation process, the grey relation coefficients were higher between actuator A and actuator B for DD, plume angle and plume width; while the coefficients between actuator A and actuator C for FPD, MMAD, ellipse ratio, spray area were higher; and for GSD, the grey relation coefficients were all consistent. Finally, it was concluded that the grey relation degree results of actuator A and actuator B were more consistent through the combination of weight and GRA method, that is, the overall difference was smaller. The method discussed in this research might be a reference for the in vitro multi-index evaluation.
The close attention in sterility test of microspheres for injection should be paid to both external sterility and internal sterility, and the difficulty for the method establishment and validation was the internal sterility test. On the basis of investigating the production process, this study selected representative products of microspheres for injection and simulated the dissolution process of the microspheres in the presence of potential microbial contaminants, established two internal sterility inspection methods, one was to dissolve the microspheres in DMSO, and the other was to dissolve the microspheres with a pH 10.0 buffer solution. The sterility test was carried out by direct inoculation method, and the bacterial-tolerant spores were used as the strains of the test microorganisms. The key technical points, such as the solution to be tested, the strains of the test microorganisms and the method suitability test, were discussed. This study could provide a beneficial reference for the development and validation of sterility test for microspheres for injection.
A quantitative analysis of multi-components by single marker (QAMS) method was established for the simultaneous determination of six components, namely genistein(2), kaempferol-3-O-rutinoside(3), kaempferol-3-O-β-D-sophoroside(4), sophoricoside(5), sophorobioside(6), kaempferol-3-O-(2″-O-β-D-glucopyranosyl)-β-D-rutinoside(7), in charred Sophora japonica(1). The relative correction factors of 2, 3, 4, 6, and 7 were calculated by UPLC method with 5 as the internal reference. The external standard method and QAMS method were compared to determine the differences in the contents of each component, and chemical pattern recognition was used to evaluate the quality of fifteen batches of 1. The results showed that there was no significant difference between the QAMS method and the external standard method(RSD<2%). The results of hierarchical cluster analysis(HCA) and orthogonal partial least square-discriminant analysis(OPLS-DA) showed that fifteen batches of 1 could be clustered into three classes. The difference was mainly manifested in the contents of 2 and 3, and the contents of ingredients varied greatly between different manufacturers and origins. The established QAMS method was accurate and feasible, which provided a reference for the quality control of 1.
An HPLC method was established for the determination of R-isomer etiracetam(2) in levetiracetam(1) injection. A CHIRALPAK IG column(4.6 mm×250 mm, 5 μm) was used with amylose tri(3-chloro-5-methylphenyl carbamate) as filler. The analysis was carried out in the isocratic elution mode with 10 mmol/L ammonium acetate∶acetonitrile(70∶30) as the mobile phase. The detection wavelength was 190 nm, the flow rate was 0.7 ml/min, the column temperature was 30 ℃, and the injection volume was 100 μl. The results showed that the separation between peaks of 2 and 1 was good under this chromatographic condition. It was linear for 2 and 1 in the ranges of 0.4 - 8.0 and 0.8 - 8.0 μg/ml, respectively, and the detection limits of 2 and 1 were 10 and 20 ng, respectively. The average recoveries(n=9) of 2 and 1 were 103.84% and 99.10%, with the RSDs of 0.81% and 1.16%, respectively. The RSDs of precision test, stability test and repeatability test were all less than 2.0%, and the durability was good. The established method was simple, accurate, reliable, sensitive and reproducible, which was suitable for the quality control of dextro-rotatory stereoisomer in 1 injection.
A pre-column derivatization HPLC method was established for the determination of other amino acids, namely aspartic acid, serine, arginine, glycine, threonine, proline, alanine, valine, methionine, cystine, isoleucine, leucine, tryptophan, isophenylalanine, histidine, lysine hydrochloride and tyrosine, in sodium glutamate. Amino acids were derivatized with 2,4-dinitrofluorobenzene. The results showed that the pre-column derivatization HPLC method had good specificity, and it was linear for above amino acids in the corresponding concentration ranges. The precision and stability of the method were good, and the average recoveries of each amino acid ranged from 90.0% to 110.0%, with the RSDs(n=9) less than 5%. The established method is accurate, reliable and reproducible, which can be used for the determination of other residual amino acids in sodium glutamate.
A crystallization process of crystal form C of pimavanserin is developed without adding crystal seeds. The industrial crystallization conditions were studied through the investigation of solubility, the selection of crystallization methods and production equipment. The crystallization process and mechanism were explored by combination of in-line and off-line monitoring. X-Ray powder diffraction(PXRD), differential scanning calorimetry(DSC) and thermogravimetric analysis(TGA) were used to investigate and control the crystal quality of the final product. The results showed that the process(suspension crystallization in butanone) was suitable for industrial production with a simple operation procedure, and the obtained crystal form C was stable and controllable.
As the latest generation of vaccine manufacturing processes, mRNA-based vaccine technology has been successfully applied in vaccine production and clinical applications, such as the coronavirus disease 2019(COVID-19) mRNA vaccine. Compared with the traditional inactivated vaccine or recombinant subunit vaccine, mRNA vaccine has the characteristics of high potency, short development cycles, safety profile, and excellent production universality. Due to the characteristics of mRNA molecules and process particularity, the traditional design concept of biological drugs cannot completely fit its production requirement. How to proceed with the process engineering design of an mRNA vaccine manufacturing facility is worth studying. Because of the high difference in national geographic locations, humanistic characteristics, energy structure, and environmental protection requirements, process engineering design solutions under our local conditions should be explored. Based on approved mRNA vaccine facilities in the United States and Europe Union, this study discusses capacity calculation and analysis based on an assumed production scale(1 billion doses per year) and explores key points of engineering design of the large-scale mRNA vaccine facility process. Production facility layout, clean area classification, personnel and material flow, pressure zones, and air flows are discussed and illustrated to provide a scheme to expedite the domestic establishment of the mRNA vaccine GMP manufacturing facility.