Latest ArticlesGranulocyte colony-stimulating factor(1) has a short half-life and is easily hydrolyzed by enzymes, so that it usually requires multiple injections in clinical application, and shows poor patient compliance. In this study, prefabricated polysaccharide particles, 1-dextran(DEX), were respectively prepared by the double aqueous emulsion and double aqueous lyophilization-induced phase separation methods, and then were loaded by poly(lactic-co-glycolic acid)(PLGA) microspheres through the S/O/W emulsion method to improve the stability of 1. The results showed that both two kinds of PLGA microspheres loaded with 1-DEX had homogenous particle size distribution, high encapsulation efficiency(>70%), 75% - 80% of total drug sustained-release in 40 days, and more than 85% of proliferative activity of mouse myeloid leukemia lymphocyte cell lines(NSF-60 cells). The PLGA microspheres loaded with 1-DEX by the two methods could improve the stability of 1 and realize sustained-release for over four weeks, providing a reference for preparing sustained-release microspheres loaded with protein drugs.
The paliperidone-loaded pill cores were prepared by the extrusion spheronization process, then the sustained-release pellets were obtained by coating with methacrylic acid copolymer(Eudragit) thin film. The formulation and process parameters of the pill cores and coated pellets were optimized by orthogonal design. The results showed that the in vitro release behavior of the optimal sustained-release pellets coated with the thin film consisted of Eudragit RS30D(which accounted for 65% of the total amount of coating materials) and Eudragit RL30D could be described by first-order kinetic equation.
The formulation parameters of the curcumin and piperine co-loaded liposomes were optimized by single factor test, Box-Behnken design and response surface methodology with encapsulation efficiencies of curcumin and piperine as the indexes. The results showed that the liposomes were prepared by thin film hydration method, and the optimal parameters were as follows: the mass ratio of lecithin to cholesterol was 5.16, the volume and temperature of the film-forming solvent was 20 mL and 40 ℃, the hydration medium volume was 20 mL, and the hydration temperature was 60 ℃. The particle size of the obtained optimized liposomes was (95.5±1.8)nm, the ζ potential was (–0.3±0.1)mV. The encapsulation efficiencies of curcumin and piperine were (97.46±0.36)% and (96.74±1.09)%, respectively; while the drug loadings of both drugs were (1.56±0.09)% and (0.07±0.01)%, respectively. The inhibitory effect of the product on the proliferation of human lung cancer cells(A549 cells) was detected by tetramethylazolium salt(MTT) colorimetric method. The results showed that the curcumin and piperine co-loaded liposomes had a stronger inhibitory effect on the proliferation of A549 cells than those of free curcumin and the curcumin liposomes. The results of Transwell migration assay showed that the number of cell migration of A549 cells after incubation with the co-loaded liposomes was significantly reduced, compared with free curcumin and the curcumin liposomes.
The aim of this paper was to optimize the dry granulation technology of modified Yupingfeng granules. Lactose, dextrin and silicon dioxide were respectively mixed with the modified Yupingfeng extract, followed by dry granulation. Then, an orthogonal test was employed to comprehensively evaluate the properties of the granules with the primary forming rate, moisture absorption rate, rate of dissolving and angle of repose as the indicators. Combined with actual industrial application, the optimal mass ratio of different excipients to the extract was selected as m(lactose)∶m(dextrin)∶m(silicon dioxide)∶m(the extract powder)=0.6∶0.4∶0.05∶1. On the basis of this ratio, the process parameters of dry granulation, namely the wheel speed, wheel rolling pressure and feeding speed, were optimized by the orthogonal test with the single effective particle forming rate, particle bulk density and fragility as indexes. The optimal dry granulation process parameters were as follows: wheel speed was 15 r/min, wheel rolling pressure was 20 MPa, and feeding speed was 80 r/min. The optimized dry granulation process of modified Yupingfeng granules was proved to be stable and feasible based on the pilot-scale test, which could provide a reference for industrial production.
At present, there is no uniform standard for enoxaparin sodium injection in the pharmacopoeia, and enoxaparin sodium injection belongs to the species with safety risks. Therefore, it is very important to supervise its quality. A follow-up inspection of the product for 3 consecutive years was carried out. The sampling range was wide, the sample specifications were complete, and the representativeness was strong, so the inspection results could better reflect the quality status of enoxaparin sodium injection nationwide. According to the daily supervision and sampling test, combined with the existing research results of national evaluation sampling test, the quality status of more than 200 batches of samples from 8 manufacturers was summarized in this paper, and the quality difference of enoxaparin sodium injection from different enterprises was evaluated. In addition, the quality consistency between the products of domestic enterprise and reference listed drug(RLD) was inspected for the first time; and the quality of RLD marketed in the Chinese market, the US market and the European market was also compared and analyzed for the first time, so as to provide references for the improvement of quality standards and the safety of clinical medication. Through investigations, inspections according to current legal standards, and exploratory research, combined with the comprehensive analysis of the scientificity and rationality of the current standards, it was found that enoxaparin sodium injection still had inconsistencies in quality standards, inconsistencies between prescription and production processes in individual enterprises, and other problems. Therefore, the current quality standards still have defects and need to be further unified and improved.
This study investigated the application of isopropyl myristate(IPM) in sample pretreatment for the microbial limit test of water-insoluble preparations. First, the effect of IPM on the growth and detection of microorganisms in the pretreated test sample was determined by the bacteria-adding recovery method. The results showed that its toxicity to microorganisms could be ignored and IPM did not affect the detection of contaminated microorganisms. Subsequently, IPM was used for sample pretreatment of five water-insoluble preparations, and the applicability of the microbial limit method was tested. The results showed that the insoluble preparations could be well dissolved in IPM. The water-insoluble test samples treated with IPM were converted into water-soluble test samples through dissolution-extraction process. The membrane filtration method can be used to eliminate the bacteriostasis of drugs and establish a simple microbial limit test method for corresponding varieties. This study shows that IPM has a good application prospect in the preparation of test solutions of water-insoluble preparations and its potential for the pretreatment of special matrix samples.
In order to evaluate the quality difference between polypropylene infusion bottles made from domestic pellets and imported pellets, sixteen batches of polypropylene infusion bottles sampled for national evaluation were tested for cytotoxicity, insoluble particles, easy oxides, n-hexane non-volatile materials, light transmittance, haze and contents of the related substances from extraction and dissolution. The results showed that there were no significant differences in easy oxides and insoluble particles in the bottles made from domestic pellets and imported pellets, and the contents of n-hexane non-volatile materials in above bottles were(118.0±30.7) and(137.1±48.2)mg, respectively. In terms of the addition amounts of antioxidants and acid scavengers, their contents in the polypropylene infusion bottles made from domestic pellets and imported pellets were controlled at the same level, which were about 0.05% and 0.25%, respectively. Based on the determination results of small-molecule volatiles, it was speculated that the same polypropylene polymerization catalyst was used in the preparation of domestic pellets and imported pellets. From the analysis of the existing projects, the polypropylene infusion bottles made from domestic pellets and imported pellets had a similar quality level. However, it is still necessary to further expand the eveluation project for a more comprehensive quality comparison.
The key parameters of vacuum decay method for the container closure integrity testing of sterile product packaging system were studied. The key parameters, namely test environment, the residual chamber volume, the sealing property of chamber, the chamber material and the process parameters, that could affect the test results were determined. Then, the tests were carried out to verify the influence of above key parameters by designing and developing research programs. The data showed that the test results could be affected by the above key parameters. It was recommended to control the test environment of 23 ℃ and the relative humidity of 45%. The selected chamber should conform to the overall dimensions of the test samples as much as possible, and the sealing ring should be replaced regularly. It was also recommended to select stainless steel material with stable performance and high sensitivity for chamber and negative samples. The negative samples should be solid or leak free based on the tested samples. The setting of process parameters should take the possible leakage risk points of samples on the basis of different packaging forms and different contents into consideration. And in the actual test, reasonable design and selection of key parameters were required to ensure scientificity of the test results.