Home Latest Articles
Latest Articles
  • Shengnan ZHU, Weijuan PENG, Xiangyang XU
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 48-55.

    Opioid analgesics are efficient drugs for moderate-to-severe pain treatment. However, they also become commonly abused drugs due to their potential addiction. Prescription opioids abuse has become a global health crisis with increasing clinical use. The development of prescription opioids with abuse-deterrent formulations(ADFs) has been encouraged by the U. S. government to reduce the abuse of prescription opioids, so the United States is a recognized leader in discovering the new dosage forms of opioid analgesics around the world. To deter prescription opioids abuse, a variety of anti-abuse technologies have been developed, including forming physical/chemical barriers, adding agonists/antagonists, adding aversions, and preparing prodrugs. Although several approved opioid ADFs have been withdrawn from the market for different reasons, ADFs have played a positive role in lowering overall abuse risks. This review summarizes the recent development of abuse-deterrent opioid analgesics and analyzes the patents of critical products, hoping to provide some references for the research and development of ADFs in China.

  • Yi XIONG, Yanwen DUAN, Xiangcheng ZHU
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 56-64.

    Surfactin(SF) is a cyclic lipopeptide biosurfactant produced by Bacillus. Due to its superior biosafety, degradability, cell membrane permeability, and resource sustainability, it has been widely studied and applied in biomedical products as a potential drug adjuvant. In this review, biosafety, mechanism on cell membrane, and applications of SF in the field of pharmaceutical products in recent years are systematically introduced. Specially, the research progress of SF as an effective adjuvant in the development of drug delivery systems is described, and the prospect of its clinical application has been illustrated.

  • Naihua ZHANG, Yongjie MA, Guanglong BAO, Yanyun SUN, Guimin ZHANG
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 65-68.

    An improved synthetic process of gimeracil(1) was developed. Starting materials malononitrile(2) and trimethyl orthoacetate were condensed to deliver 2-(1-methoxyethylidene)malononitrile(3), which was in turn reacted with triethyl orthoformate to produce 1,1-dicyano-2-methoxy-4-ethoxy-1,3-butadiene(4). Intramolecular cyclization of 4 in 80% aqueous acetic acid proceeded smoothly to afford 3-cyano-4-methoxy-2(1H)-pyridone(5), which was subjected to sulfonyl chloride to generate 5-chloro-3-cyano-4-methoxy-2(1H)-pyridone(6). Finally, 6 on exposure to 30% aqueous sulfuric acid was transformed into the target compound 1 with an overall yield of 62% (based on 2) and an HPLC purity of 99.88%. The synthetic method for 5 from 4 has not yet been reported in literature. The optimized synthetic process was more stable and operationally simpler, which was suitable for industrial production.

  • Liying JIA, Lingli CHEN, Kaoxiang SUN
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 69-76.

    Reduction-responsive amphiphilic polymer PEG-SS(O)-SN38 was synthesized by conjugation of polyethylene glycol(PEG2000) and the active metabolite SN-38 of irinotecan by disulphide bonds. Then, the self-assembled micelles were prepared by thin-film dispersion method. The transmission electron microscopy(TEM) observation revealed that the micelles were spherical in shape. The average particle size and polydispersion index measured by dynamic light scattering were (106.3±0.5)nm and 0.19±0.05. The critical micelle concentration(CMC)measured by fluorescence method was (0.070±0.008)mg/ml, suggesting that the formed micelles could maintain structural integrity. The content of SN38 released from the micelles increased to (66.55±0.53)% after incubation for 2 h in the simulated reductive tumor microenvironment in vitro. The cumulative release amounts at 48 h of the self-assembled micelles were (50.24±4.53)% in pH 7.4 phosphate buffer(PBS) and (57.43±2.92)% in fetal bovine serum(FBS), which proved that the self-assembled PEG-SS(O)-SN38 micelles had sustained-release effects. In addition, the particle sizes of the self-assembled PEG-SS(O)-SN38 micelles were almost unchanged in PBS for 24 h and in FBS for 8 h. The results showed that the self-assembled PEG-SS(O)-SN38 micelles had good stability in a simulated physiological environment. In vitro cytotoxicity showed that the self-assembled PEG-SS(O)-SN38 micelles had a significant growth inhibition effect on human pancreatic cancer(Capan-1) cells. Furthermore, compared with irinotecan hydrochloride injection at the same dose, the self-assembled PEG-SS(O)-SN38 micelles exhibited significant tumor inhibition in the Capan-1 tumor-bearing nude mice without a remarkable decrease in body weight.

  • Xuan WANG, Lan CHEN, Donghao CHEN
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 77-85.

    This research investigated the effect of airflow rate on drug powder dispersion and deposition performance of carrier-based dry powder inhaler with HandiHaler®. The formulation model was prepared by mixing the carrier lactose Lactohale 206 and the micronized chlorpheniramine maleate. The next-generation pharmaceutical impactor(NGI) was used to analyze the powder deposition at the airflow rates of 20, 30, 40, 50 and 60 L/min, respectively. Meanwhile, the coupled computational fluid dynamics and discrete element method was adopted to evaluate the dispersion behaviors of the powder particles with two different shapes(spherical and non-spherical) at variant airflow rates. The reults showed that the drug residues in the capsule and the device decreased with the increase of air flow rate. However, the powder dispersion performance rarely changed. Furthermore, the computer simulation results were consistent with the in vitro experimental outcomes, which could help to understand the dispersion process. In this study, the system of inhalation powders and Handihaler® was relatively independent of the air flow rate, and the effective deposition amount was stable. The relationships between particle collision or relative motion(between particles and airflow) and fine particle dose were respectively established. Comparing to the spherical particle model, the non-spherical particle model of the carrier lactose was more reliable in the simulation, thus the non-spherical model should be better for the numerical analysis of the dispersion process.

  • Liping DU, Li ZHANG, Guizhou HAO, Shankui LIU, Guimin ZHANG
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 86-94.

    The aim of this study is to establish an in vitro release test method for the novel galantamine sustained-release microspheres for injection. Galantamine stearate was synthesized, then its microspheres with poly(lactide-co-glycolide) as carriers were prepared by oil-in-water emulsion solvent evaporation method. The prepared microspheres were characterized in terms of morphology, particle size, drug loading and encapsulation efficiency. The SD rats were used as the animal models to study the in vivo drug release behaviors of the microspheres, and the cumulative release curve in vivo was drawn. In order to obtain the parameters of in vitro release test method for the microspheres with good in vivo relevance, Plackett-Burman design was used to screen out the significant factors affecting the release data of microspheres by flow-through cell method. Then, the central composite design-response surface methodology was used to investigate the influences of the selected factors and their interactions on the release behaviors. The results showed that the flow rate of piston pump, the release medium temperature, and the concentration of bovine serum albumin(BSA) in release medium were significant factors affecting the in vitro release data of the microspheres measured by flow-through cell method. Based on the fitting results by Design-Expert 8.06 software, the optimized parameters were as follows: the flow rate of piston pump, the medium temperature and BSA concentration in release medium were 10.55 ml/min, 42.54 ℃and 1.25%, respectively. The in vitro release data of the microspheres measured under this condition had a good correlation with the in vivo release behavior in rats.

  • Minhang ZHU, Jing ZHOU, Yunhui XU, Fengkun XIAO, Moli HUA
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 95-100.

    Two HPLC methods were established for the determination of tetrahydrocannabinol(1), cannabidiol(2) and cannabidiolic acid(3) in domestic hemp leaves and flowers. An Agilent Extend C18 column was used with the detection wavelength of 220 nm. The mobile phase composed of acetonitrile and 0.1% phosphoric acid aqueous solution(76∶24) was used to determine 1. The gradient elution of 0.1% phosphoric acid aqueous solution with acetonitrile was used to determine 2 and 3 simultaneously. The results showed that the methods were verified to have good separation and specificity. And it was linear for 1 in the range of 0.001 - 0.1 mg/ml, and it was linear for 2 and 3 in the range of 0.01 - 1 mg/ml. The limits of quantification for 1, 2 and 3 were 1.5, 1.0 and 1.0 ng, respectively, and the detection limits were 0.5, 0.4 and 0.4 ng, respectively. The average recoveries(n=9) of sample addition were 95.27%, 102.19% and 98.85% with RSDs of 5.22%, 3.19% and 1.69%, respectively. The established method could be used to determine 1, 2 and 3 in domestic hemp leaves and flowers.

  • Jianhui ZHAO, Yiwen MA, Shiqiao LI, Hongjuan PAN
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 101-107.

    An online solid phase extraction(SPE)-high performance liquid chromatography(HPLC)-diode array detection(DAD) method was established for the determination of seven nitrogen oxide genotoxic impurities in lansoprazole(1) and its preparations, namely lansoprazole N-oxide(2), lansoprazole sulfone N-oxide(3), lansoprazole sulphide N-oxide(4), lansoprazole impurity G(5), 2,3-dimethyl-4-(2,2,2-trifluoroethyl)pyridine-N-oxide(6),2,3-dimethyl-4-nitropyridine-N-oxide(7) and 2,3-dimethylpyridine-N-oxide(8). The XB-C18 online SPE column(4.6 mm×50 mm, 4.6 μm) was used, and the analytical column was XB-C18 column(4.6 mm×250 mm, 4.6 μm). And the sample was removed by switching the six-way valve. The analysis was carried out in the gradient elution mode with 15 mmol/L dipotassium hydrogen phosphate solution as mobile phase A, and methanol as mobile phase B. Seven impurities were detected with multiple wavelengths, 285 nm for 2, 3, 4 and 5, 260 nm for 6 and 8, and 310 nm for 7. The results showed that the separation among the seven impurities all met the requirements, and it was linear for 2 - 8 in the corresponding concentration range. The limits of quantification and detection of the seven impurities were 4 and 2 μg/g, respectively. This method had good repeatability and accuracy, which provided a reference for the quality control of 1 and its preparations.

  • Jiang XIAO, Haitao SHUAI, Fan CHEN, Zhiyuan HUANG, Xiangfeng WANG, Fangwen SHUAI
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 108-112.

    A gas chromatography method was established to determine the composition of fatty acids in stearic acid. Before detection, the methyl esterification reaction was conducted to convert the fatty acids in stearic acid into fatty acid methyl esters. The DB-FFAP capillary column(30 m×0.32 mm×0.5 μm) was used. The initial column temperature was set at 70 ℃ for two minutes, followed by incraesing to the final temperature of 240 ℃ for twenty-four minutes with a rate of 5 ℃/min. The temperature of the injection port was 220 ℃, the temperature of the flame ionization detector was 260 ℃, and the split ratio was 10∶1. The peak area normalization method was used to calculate the content of each fatty acid methyl ester. The results showed that all peaks of the sixteen fatty acid methyl ester could be effectively separated. It was linear for all of them in the range of 1 - 100 μg/ml. The precision and stability were good, and the detection limit of each fatty acid was lower than 3.4 μg/g. In addition, twenty-five batches of stearic acid samples from seven domestic and foreign manufacturers were tested, and they all met the current standards.

  • Jialin DONG, Nan JIANG, Youzhi JIA, Hongjuan PAN
    Chinese Journal of Pharmaceuticals. 2022, 53(1): 113-118.

    An ultra-high performance liquid chromatography-ultraviolet(UPLC-UV) dual-wavelength method was established for the simultaneous determination of eight residues in acrylic skeleton ion-exchange resin, namely acrylic acid(1), methacrylic acid(2), methyl acrylate(3), methyl methacrylate(4), ethyleneglycol dimethacrylate(5), N-propyl methacrylate(6), divinylbenzene(7) and naphthalene(8). A Thermo Acclaim-C18 column was used, and the analysis was carried out in the gradient elution mode with 10 mmol/L potassium dihydrogen phosphate solution as mobile phase A, and acetonitrile as mobile phase B. The detection wavelengths for 1, 2, 3, 4, 5, 6, 8 were 210 nm, and for 7 was 237 nm. According to the methodological verification, the established method had good specificity and accuracy. The limits of quantification and detection of the eight residues were 0.03 - 0.12 μg/ml and 0.01 - 0.04 μg/ml, respectively.

News