收藏切换
Effect of Inhalation Profiles on the in vitro Deposition Performance of Dry Powder Inhaler Models
收藏切换
Fei WU1, Lan CHEN1, 2, *, Donghao CHEN2
Chinese Journal of Pharmaceuticals | 2023, 54(10) : 1467 - 1474
Less
收藏切换
Chinese Journal of Pharmaceuticals | 2023, 54(10): 1467-1474
• Paper •
Effect of Inhalation Profiles on the in vitro Deposition Performance of Dry Powder Inhaler Models
Full
Fei WU1, Lan CHEN1, 2, *, Donghao CHEN2
Affiliations
  • 1.School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093
  • 2.Hangzhou Chance Pharmaceuticals Co., Ltd., Hangzhou 311121
Published: 2023-10-10 doi: 10.16522/j.cnki.cjph.2023.10.010
Outline
收藏切换

The effects of peak inhalation flow rate(PIFR) and flow increase rate(FIR) on the in vitro deposition performance of three dry powder inhaler(DPI) models with different fine lactose ratios were investigated. Three formulations(formulation A with a fine lactose ratio of 10%, formulation B of 5%, and formulation C without fine lactose) were prepared by mixing budesonide with coarse lactose carrier and fine lactose. The efficiency of particle deposition was assessed by using the Alberta idealized mouth-throat model and a next generation impactor system. In vitro testing was performed at PIFRs of 30, 60, and 90 L/min and two FIRs(representing fast and slow inhalation conditions, respectively). The total lung dose(TLD) of formulations A and B showed a dependence on PIFR; but the TLD of formulation C which was not affected by PIFR was most affected by FIR. In addition, the small airways dose(SAD) of all three formulations was significantly higher at fast FIR than those at slow FIR(P<0.05). In addition to PIFR, FIR was an important factor affecting the in vitro performance of DPI. Within the scope of the experiments in this study, the fine lactose ratio of the formulations had a positive correlation with the deposition performance, showing a lower sensitivity to the FIR, but was more dependent on the PIFR.

dry powder inhaler  /  budesonide  /  fine lactose  /  inhalation profile  /  Alberta idealized mouth-throat model  /  in vitro evaluation
吴飞, 陈岚, 陈东浩. 吸气模式对吸入粉雾剂模型体外沉积性能的影响. 中国医药工业杂志, 2023 , 54 (10) : 1467 -1474 . DOI: 10.16522/j.cnki.cjph.2023.10.010
Fei WU, Lan CHEN, Donghao CHEN. Effect of Inhalation Profiles on the in vitro Deposition Performance of Dry Powder Inhaler Models[J]. Chinese Journal of Pharmaceuticals, 2023 , 54 (10) : 1467 -1474 . DOI: 10.16522/j.cnki.cjph.2023.10.010
Year 2023 volume 54 Issue 10
20
4
Cite this Article
BibTeX
Article Info
doi: 10.16522/j.cnki.cjph.2023.10.010
  • Receive Date:2023-03-20
  • Online Date:2026-11-19
  • Published:2023-10-10
Article Data
Affiliations
History
  • Received:2023-03-20
Affiliations
    1.School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093
    2.Hangzhou Chance Pharmaceuticals Co., Ltd., Hangzhou 311121
References
Share
https://castjournals.cast.org.cn/joweb/zgyygy/EN/10.16522/j.cnki.cjph.2023.10.010
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT