In order to assist tunnel fire risk management and decision-making,the definition and principles of social risk acceptance criteria for road tunnel fire were established. Based on a statistical analysis of tunnel fire fatalities in China from 2000 to 2020 and a survey of public perceptions of tunnel fire risk,social risk acceptance criteria of tunnel fires in China was developed by the F/N curve method,and the acceptance critical limits for accident frequency and consequences were defined. The results show that the public has a tolerable attitude towards the current situation of tunnel fire accident risk. The maximum acceptable frequency of tunnel fire fatalities in China is set at 10-5/(km·a),and the maximum tolerable frequency is set at 10-4/(km·a).