收藏切换
Effect of 131I nuclide therapy operation mode correction on radiation safety risk
收藏切换
PDF
Jiangping FENG1, Jinfan ZHANG1, Feng CHEN2, Zehua LIN1, Jianfeng GUO1, Yong LIU3, **
China Safety Science Journal | 2024, 34(8) : 231 - 237
Less
收藏切换
China Safety Science Journal | 2024, 34(8): 231-237
Occupational health
Effect of 131I nuclide therapy operation mode correction on radiation safety risk
Full
Jiangping FENG1, Jinfan ZHANG1, Feng CHEN2, Zehua LIN1, Jianfeng GUO1, Yong LIU3, **
Affiliations
  • 1 Shenzhen Ecological and Environmental Monitoring Center of Guangdong Province,Shenzhen Guangdong 518049,China
  • 2 Shenzhen Ecological Environment Bureau,Shenzhen Guangdong 518113,China
  • 3 Institute for Advanced Study in Nuclear Energy & Safety,Shenzhen University,Shenzhen Guangdong 518060,China
Published: 2024-08-28 doi: 10.16265/j.cnki.issn1003-3033.2024.08.1612
Outline
收藏切换

To protect the occupational health and safety of 131I nuclear therapy workers and increase the utilization rate of 131I nuclear therapy,131I nuclear therapy workplaces in 10 hospitals in Shenzhen were selected in this study. The iodine box filter membrane sampling method,combined with a low background high-purity germanium γ energy spectrometer and passive efficiency calibration software,was used to measure the 131I activity concentration in critical areas of nuclear medicine workplaces. The accumulated effective dose of occupational personnel was estimated,and then the radiation safety risk of occupational personnel was evaluated. Furthermore,the effect of the correction factor change of 131I nuclide treatment operation on the radiation safety risk of occupational personnel was analyzed. The results showed that when the correction factor of 131I (liquid) nuclide treatment operation mode was set to 10,the radiation safety risk was far below the standard limit for manufacturer delivery and automatic packaging in nuclear medicine workplaces. It was recommended that the correction factor of the operation model of 131I (liquid) radionuclide therapy be distinguished by the packaging system,with manual packaging set to 1 and manufacturer delivery and automatic packaging set to 10.

131I nuclear therapy  /  operating mode  /  correction factor  /  radiation safety risk  /  nuclear medicine workplace  /  internal radiation
Jiangping FENG, Jinfan ZHANG, Feng CHEN, Zehua LIN, Jianfeng GUO, Yong LIU. Effect of 131I nuclide therapy operation mode correction on radiation safety risk[J]. China Safety Science Journal, 2024 , 34 (8) : 231 -237 . DOI: 10.16265/j.cnki.issn1003-3033.2024.08.1612
Year 2024 volume 34 Issue 8
PDF
360
139
Cite this Article
BibTeX
Article Info
doi: 10.16265/j.cnki.issn1003-3033.2024.08.1612
  • Receive Date:2024-02-26
  • Online Date:2025-07-09
  • Published:2024-08-28
Article Data
Affiliations
History
  • Received:2024-02-26
  • Revised:2024-05-26
Funding
Affiliations
    1 Shenzhen Ecological and Environmental Monitoring Center of Guangdong Province,Shenzhen Guangdong 518049,China
    2 Shenzhen Ecological Environment Bureau,Shenzhen Guangdong 518113,China
    3 Institute for Advanced Study in Nuclear Energy & Safety,Shenzhen University,Shenzhen Guangdong 518060,China
References
Share
https://castjournals.cast.org.cn/joweb/zgaqkxxb/EN/10.16265/j.cnki.issn1003-3033.2024.08.1612
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT