收藏切换
Determination of vitamin A and vitamin E in human tear by liquid chromatography-tandem mass spectrometry and analysis of their relationship with dry eye
收藏切换
Baobin LUO1, Jingran JIAO2, Jing BAI1, Xiangyi LIU1, *
Chinese Journal of Chromatography | 2026, 44(3) : 296 - 301
Less
收藏切换
Chinese Journal of Chromatography | 2026, 44(3): 296-301
• Article •
Determination of vitamin A and vitamin E in human tear by liquid chromatography-tandem mass spectrometry and analysis of their relationship with dry eye
Full
Baobin LUO1, Jingran JIAO2, Jing BAI1, Xiangyi LIU1, *
Affiliations
  • 1Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
  • 2Beijing Youan Hospital, Capital Medical University, Beijing 100069, China
Published: 2026-03-08 doi: 10.3724/SP.J.1123.2025.06017
Outline
收藏切换

Dry eye is characterized as a multifactorial disorder affecting the tear film and ocular surface, leading to symptoms of discomfort and visual disturbances, with the potential for ocular surface damage. It is among the most prevalent ocular surface disorders, with an estimated prevalence ranging from 5.0% to 50.0%, and an overall prevalence between 21.0% and 50.4% in China. Despite its high global prevalence, the fundamental mechanisms underlying the pathology of dry eye remain largely unexplored. Vitamins are crucial for maintaining ocular surface homeostasis, with vitamins A and E being physiologically present and essential for cell differentiation, development, and proper function. Deficiencies in these vitamins are frequently associated with dry eye, and systemic supplementation has been shown to benefit patients with low vitamin intake. Vitamins A and E may have potential clinical predictive value for the diagnosis and treatment of dry eye. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously measure the concentrations of vitamins A and E in human tears. A Phenomenex Kinetex C18 column was employed for gradient elution at a flow rate of 0.4 mL/min. The mobile phase A consisted of a 0.1% formic acid aqueous solution, while mobile phase B comprised a 2 mmol/L ammonium acetate and 0.1% formic acid methanol solution. Positive atmospheric pressure chemical ionization in multiple reaction monitoring mode was utilized for MS/MS detection. The analytical method for vitamin A demonstrated a validated linear range of 5.00-300.00 ng/mL, with a limit of detection at 2.00 ng/mL. The spiked recoveries were between 98.3% and 104.7%, and intra- and inter-day precision ranged from 1.2% to 7.0%. Similarly, the method for vitamin E exhibited a validated linear range of 25.00-1 000.00 ng/mL, with a limit of detection at 6.00 ng/mL. The spiked recoveries ranged from 97.9% to 105.5%, and intra- and inter-day precision varied between 3.0% and 5.7%. Tear samples from five patients with dry eye and nine healthy volunteers were analyzed using this method. In the dry eye group, the average concentrations of vitamin A and vitamin E were 9.60 (5.13-12.54) ng/mL and 42.00 (31.75-128.00) ng/mL, respectively. In the healthy group, the average concentrations of vitamin A and vitamin E were 18.10 (12.46-21.69) ng/mL and 211.00 (181.00-459.75) ng/mL, respectively. Statistical differences in vitamin A and vitamin E levels between the dry eye group and the healthy group were identified using the Wilcoxon Mann-Whitney test (P<0.05). This study introduces a straightforward and reliable LC-MS/MS method for the detection of tear VA and VE levels, while also investigating their association with dry eye. This offers a novel reference for understanding the potential risk factors associated with dry eye.

liquid chromatography-tandem mass spectrometry (LC-MS/MS)  /  tears  /  dry eye  /  vitamin A  /  vitamin E
罗保斌, 焦婧然, 白晶, 刘向祎. 液相色谱-串联质谱法测定泪液中维生素A和维生素E及其与干眼的关系分析. 色谱, 2026 , 44 (3) : 296 -301 . DOI: 10.3724/SP.J.1123.2025.06017
Baobin LUO, Jingran JIAO, Jing BAI, Xiangyi LIU. Determination of vitamin A and vitamin E in human tear by liquid chromatography-tandem mass spectrometry and analysis of their relationship with dry eye[J]. Chinese Journal of Chromatography, 2026 , 44 (3) : 296 -301 . DOI: 10.3724/SP.J.1123.2025.06017
Year 2026 volume 44 Issue 3
41
19
Cite this Article
BibTeX
Article Info
doi: 10.3724/SP.J.1123.2025.06017
  • Receive Date:2025-06-16
  • Online Date:2026-10-27
  • Published:2026-03-08
Article Data
Affiliations
History
  • Received:2025-06-16
Affiliations
    1Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
    2Beijing Youan Hospital, Capital Medical University, Beijing 100069, China
References
Share
https://castjournals.cast.org.cn/joweb/sepu/EN/10.3724/SP.J.1123.2025.06017
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT