收藏切换
Determination of 13 janus kinase inhibitors in anti-alopecia cosmetics by ultra-high performance liquid chromatography-tandem triple quadrupole composite linear ion trap mass spectrometry
收藏切换
Leilei FAN, Maoqin CHEN, Haibo WANG, Qiuhong YANG
Chinese Journal of Chromatography | 2025, 43(10) : 1100 - 1108
Less
收藏切换
Chinese Journal of Chromatography | 2025, 43(10): 1100-1108
• Articles •
Determination of 13 janus kinase inhibitors in anti-alopecia cosmetics by ultra-high performance liquid chromatography-tandem triple quadrupole composite linear ion trap mass spectrometry
Full
Leilei FAN, Maoqin CHEN, Haibo WANG, Qiuhong YANG
Affiliations
  • Henan Institute for Drug and Medical Device Inspection (Henan Vaccine Issuance Center),Zhengzhou 450018,China
Published: 2025-10-08 doi: 10.3724/SP.J.1123.2025.02008
Outline
收藏切换

According to the Safety and Technical Specification for Cosmetics (2015), the addition of chemical drugs to cosmetics is strictly prohibited. Anti-alopecia cosmetics are often found to contain illegal additions of prohibited drugs such as minoxidil, finasteride and other substances. Ultra-high performance liquid chromatography-tandem triple quadrupole-linear ion trap mass spectrometry (UHPLC-Q-TRAP/MS) has become a powerful technology for the simultaneous detection of illegal ingredients in cosmetics due to its advantages of rapid analysis, high sensitivity, high throughput and high selectivity. An ultra-high performance liquid chromatography-multiple reaction monitoring-information dependent acquisition-enhanced production scanning (UHPLC-MRM-IDA-EPI) method was developed to determine 13 JAK inhibitors in anti-alopecia cosmetics, including baricitinib, tofacitinib, ritlecitinib, peficitinib, abrocitinib, upadacitinib, ivarmacitinib, fedratinib, filgotinib, ruxolitinib, momelotinib, pacritinib and bozitinib. The influence of extraction solvents was investigated. Approximately 0.2 g of the sample was weighed and placed in a 50 mL graduated centrifuge tube with a cap. Then, 2 mL of 0.1% (v/v) aqueous formic acid and 10 mL of acetonitrile were added, followed by vortexing for 1 min. Subsequently, the mixture was sonicated in an ultrasonic bath for 15 min. Added 0.5 g of sodium chloride, and the mixture was centrifuged at 8 000 r/min for 8 min at 5 °C. The supernatant was transferred to another 50 mL graduated centrifuge tube with a cap. The residue was added with 10 mL of acetonitrile and the extraction procedure was repeated. After high-speed centrifugation, the supernatant was combined. The combined supernatant was added with 0.2 g of sodium chloride, and the mixture was frozen at ‒20 °C for 1 h. It was centrifuged at 8 000 r/min for 5 min at 5 °C. The acetonitrile layer was collected and filtered through a 0.22 μm organic filter membrane. The initial filtrate was discarded, and the subsequent filtrate was collected as the sample solution. A C18 column was used for chromatographic separation, enabling the successful separation of the analytes within 10 min. The mobile phase consisted of 0.1% (v/v) aqueous formic acid and acetonitrile, with gradient elution applied to optimize separation efficiency. The flow rate was set at 0.3 mL/min, and the column temperature was maintained at 40 ℃ to ensure consistent performance. A fixed injection volume of 2 μL was used to guarantee reproducibility and accuracy in the analysis. This configuration enabled the rapid and reliable separation of the target compounds. For the analysis of the 13 kinds of JAK inhibitors, an ESI source operating in positive ion mode was used with MRM-IDA-EPI detection. Quantification was performed by the external standard method using matrix-matched standard solutions. Good separation of the 13 JAK inhibitors was achieved under the optimized chromatographic conditions. Calibration curves were constructed by plotting the peak area of quantitative ions against the compound mass concentration. These curves exhibited excellent linearity within the investigated concentration range, with r all exceeding 0.996. The limits of detection (LODs) and limits of quantification (LOQs) of the 13 JAK inhibitors were 1.5–1.7 ng/g and 9.2–10.9 ng/g. To validate accuracy and precision, two cosmetic matrices (water-soluble and cream) were tested at three levels: LOQ, 2×LOQ and 10×LOQ. Recoveries of the 13 JAK inhibitors ranged from 94.7% to 102.2% for the water-soluble matrix and from 92.4% to 99.2% for the cream matrix, with relative standard deviations (RSDs) ≤8.8%. This method is characterized by high efficiency, rapidity, accuracy, sensitivity and simplicity, making it a powerful tool for rapid risk screening and simultaneous quantitative analysis of JAK inhibitors in anti-alopecia cosmetics.

anti-alopecia cosmetics  /  ultra-high performance liquid chromatography-triple quadrupole composite linear ion trap mass spectrometry (UHPLC-Q-TRAP/MS)  /  janus kinase (JAK) inhibitors  /  illegally added
樊磊磊, 陈茂钦, 王海波, 杨秋红. 超高效液相色谱-三重四极杆复合线性离子阱质谱法测定防脱发化妆品中13种酪氨酸激酶抑制剂. 色谱, 2025 , 43 (10) : 1100 -1108 . DOI: 10.3724/SP.J.1123.2025.02008
Leilei FAN, Maoqin CHEN, Haibo WANG, Qiuhong YANG. Determination of 13 janus kinase inhibitors in anti-alopecia cosmetics by ultra-high performance liquid chromatography-tandem triple quadrupole composite linear ion trap mass spectrometry[J]. Chinese Journal of Chromatography, 2025 , 43 (10) : 1100 -1108 . DOI: 10.3724/SP.J.1123.2025.02008
  • 2024 National Cosmetic Sampling Inspection (Central Subsidized Local Fund Project)(No.41)
  • Science and Technology Plan Project of Administration for Market Regulation Henan Province(HNSCJGK202434)
Year 2025 volume 43 Issue 10
37
20
Cite this Article
BibTeX
Article Info
doi: 10.3724/SP.J.1123.2025.02008
  • Receive Date:2025-02-25
  • Online Date:2026-10-30
  • Published:2025-10-08
Article Data
Affiliations
History
  • Received:2025-02-25
Funding
2024 National Cosmetic Sampling Inspection (Central Subsidized Local Fund Project)(No.41)
Science and Technology Plan Project of Administration for Market Regulation Henan Province(HNSCJGK202434)
Affiliations
    Henan Institute for Drug and Medical Device Inspection (Henan Vaccine Issuance Center),Zhengzhou 450018,China
References
Share
https://castjournals.cast.org.cn/joweb/sepu/EN/10.3724/SP.J.1123.2025.02008
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT