收藏切换
Monitoring of Tilt Deformation of Substation Column Supported by 3D Laser Point Cloud
收藏切换
PDF
Jin-bo WU1, Xiao-chun ZHANG1, Wei-fei HU2, Jun-tao CHEN1
Water Resources and Power | 2023, 41(2) : 150 - 153
Less
收藏切换
Water Resources and Power | 2023, 41(2): 150-153
WATER CONSERVANCY AND HYDROPOWER ENGINEERING
Monitoring of Tilt Deformation of Substation Column Supported by 3D Laser Point Cloud
Full
Jin-bo WU1, Xiao-chun ZHANG1, Wei-fei HU2, Jun-tao CHEN1
Affiliations
  • 1.State Key Laboratory of Water Resources and Hydropower Engineering Science, Wuhan University, Wuhan 430072, China
  • 2.Jinshuitan Hydropower Plant, State Grid Zhejiang Electric Power Co., Ltd., Lishui 323000, China
Published: 2023-02-25 doi: 10.20040/j.cnki.1000-7709.2023.20221045
Outline
收藏切换

Columns are commonly used in water conservancy project to support the upper structure. In order to ensure the stability of the upper structure, it is necessary to monitor the deformation of the column to ensure that the inclination angle of the column is within the allowable range. The non-contact measurement and high-precision point cloud data acquisition was carried out by the total station scanner used waveform digital ranging technology. During the acquisition process, the three-dimensional coordinates of each observation station were calculated by the rear intersection method, and the observation data was unified into a coordinate system. Data registration avoided the transmission of observation errors. This paper proposed a method for calculating the tilt deformation of the column using the point cloud. After collecting the two phases of the point cloud data, the deformation was calculated based on the true pair of points, and the point and surface optimization algorithm was used to reduce the error, and the tilt angle of the column was calculated. Finally, a simulation test of the tilted deformation of the column was designed to verify the accuracy of the deformation calculation method. The test results show that the actual inclination angle is 0°16'49", the calculated inclination angle is 0°16'57", the algorithm error is less than 20', which meets the requirement of deformation monitoring in high-rise structure. Therefore, the deformation calculation method can be applied to the field of column tilt deformation monitoring.

total station scanner  /  point cloud processing  /  rear intersection method  /  isolated point cloud selection  /  tilt deformation
Jin-bo WU, Xiao-chun ZHANG, Wei-fei HU, Jun-tao CHEN. Monitoring of Tilt Deformation of Substation Column Supported by 3D Laser Point Cloud[J]. Water Resources and Power, 2023 , 41 (2) : 150 -153 . DOI: 10.20040/j.cnki.1000-7709.2023.20221045
Year 2023 volume 41 Issue 2
PDF
103
15
Cite this Article
BibTeX
Article Info
doi: 10.20040/j.cnki.1000-7709.2023.20221045
  • Receive Date:2022-05-17
  • Online Date:2026-01-27
  • Published:2023-02-25
Article Data
Affiliations
History
  • Received:2022-05-17
  • Revised:2022-06-18
Funding
Affiliations
    1.State Key Laboratory of Water Resources and Hydropower Engineering Science, Wuhan University, Wuhan 430072, China
    2.Jinshuitan Hydropower Plant, State Grid Zhejiang Electric Power Co., Ltd., Lishui 323000, China
References
Share
https://castjournals.cast.org.cn/joweb/sdnykx/EN/10.20040/j.cnki.1000-7709.2023.20221045
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT