In order to investigate the bouncing behavior in the force-displacement curves for PDMS, F-PDMS, and silicone oil swelled PDMS surfaces, we complement the macroscopic adhesive force results with the analysis of the curing interface morphology and chemical composition by using scanning electron microscope (SEM), stereomicroscope and X-ray photoelectron spectroscope (XPS). For PDMS, cured resin directly drags parts of PDMS substrate away in micro-scales, as the cured resin is in full contact with the curing interface (Figure
3(c) and Figure S8). In general, decreasing the surface energy can result in higher repellency [
39]. Though F-PDMS has a lower surface energy than PDMS (Table S3), it still cannot prevent the damage of the surface. With the lifting of the supporting plate, much more parts of PDMS (Figures
3(c
1)-
3(c
2)) are dragged away, which in turn leads to a gradual larger adhesive force and a gradual larger separation distance (Figure
3(a), red line and black line). In addition, due to the intermittent sticking and separation of the cured resin on PDMS, F-PDMS, or silicone oil swelled PDMS surface, pinched structures appear on the sidewall of the printed sample (Figures S7d-S7e). For S-PDMS, the chemical composition remained unchanged and the surface morphology cannot be damaged by the
in situ cured resin. Even after an extensive period of printing process over 100 minutes (Figure S9), the S-PDMS surface shows very low adhesive force (Figure
3(b)) and almost unchanged morphology both on the S-PMDS surface (Figures
3(c
3) and
3(c
4)) and the sidewall of the columnar sample (Figure S7f). This behavior is ascribed to the 100-200
μm depth perfluorocarbon infused PDMS (Figures S10a-S10b), which transfers the high solid-solid adhesion to low solid-liquid-solid adhesion between the cured resin and the curing interface. In detail, the infusion leads to micro-scaled wormlike channels with a geometrical dimension of ~ 3
μm (Figures S10c-S10d) and nanoscaled holes with a diameter ranging from 10 nm to 400 nm (Figure S10e). Considering the dimension of the holes, the pressure for confining the entrapped perfluorocarbon is large enough to stably hold the infused perfluorocarbon without leaking even under severe curing (Figure S4). For silicone oil swelled PDMS, when using polyacrylate resin system, the damage of the surface appears due to the miscibility of the silicone oil with the liquid resin, which can be reflected in the force-displacement curve and the sidewall of the cured model, the results of which are similar to the results of PDMS surface (orange line in Figures
3(a) and
3(c
5)-
3(c
6), Figure S7g, and Figure S11). When using polyurethane acrylate resin, the adhesive force is low and the force-displacement curve is similar to the S-PDMS surface (Figure S5d). However, rough structures still occur on the sidewall of the cured model (Figure S7h, Movie S3). In a word, the S-PDMS surface with ultra-low adhesive energy demonstrates excellent stability and durability as the curing interface for continuous 3D printing.