收藏切换
Progress in Procalcitonin Detection Based on Immunoassay
收藏切换
PDF
Jiayue Huang1, Yan Zu2, *, Lexiang Zhang2, 3, *, Wenguo Cui1, 4, *
Research. Vol 7 Article ID 0345
Less
收藏切换
Research. Vol 7 Article ID 0345
Review Article
Progress in Procalcitonin Detection Based on Immunoassay
Full
Jiayue Huang1, Yan Zu2, *, Lexiang Zhang2, 3, *, Wenguo Cui1, 4, *
Affiliations
  • 1State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-targeting Theranostics, Guangxi Key Laboratory of Bio-targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning, Guangxi 530021, P.R. China.
  • 2Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health); Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325000, P.R. China.
  • 3Joint Centre of Translational Medicine, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325035, P.R. China.
  • 4Department of Orthopedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopedics,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai 200025, P.R. China.
Published: 2024-04-16 doi: 10.34133/research.0345
Outline
收藏切换

Procalcitonin (PCT) serves as a crucial biomarker utilized in diverse clinical contexts, including sepsis diagnosis and emergency departments. Its applications extend to identifying pathogens, assessing infection severity, guiding drug administration, and implementing theranostic strategies. However, current clinical deployed methods cannot meet the needs for accurate or real-time quantitative monitoring of PCT. This review aims to introduce these emerging PCT immunoassay technologies, focusing on analyzing their advantages in improving detection performances, such as easy operation and high precision. The fundamental principles and characteristics of state-of-the-art methods are first introduced, including chemiluminescence, immunofluorescence, latex-enhanced turbidity, enzyme-linked immunosorbent, colloidal gold immunochromatography, and radioimmunoassay. Then, improved methods using new materials and new technologies are briefly described, for instance, the combination with responsive nanomaterials, Raman spectroscopy, and digital microfluidics. Finally, the detection performance parameters of these methods and the clinical importance of PCT detection are also discussed.

Jiayue Huang, Yan Zu, Lexiang Zhang, Wenguo Cui. Progress in Procalcitonin Detection Based on Immunoassay[J]. Research, 2024 , 7 (4) : 0345 . DOI: 10.34133/research.0345
Procalcitonin (PCT) is a 166-amino-acid precursor produced by thyroid C cells. It is not only considered an acute indicator for differential diagnosis but also widely used as a parameter to monitor inflammatory activity [1,2]. The detection of PCT holds immense importance in the diagnosis, treatment, and prognosis evaluation of bacterial infections. By closely monitoring PCT levels, physicians can precisely identify the type and severity of the infection. This information enables them to individualize antibiotic therapy based on the specific needs of each patient, minimize antibiotic misuse, and formulate targeted treatment plans [35]. Marked strides have been made in the clinical immunoassay of PCT, and chemiluminescence stands out as the most widelyX employed method for PCT detection. However, this method faces challenges including an extra luminescence process, pronounced background interference, reagent instability, and suboptimal detection accuracy [6]. To address these shortcomings, numerous studies have focused on enhancing PCT immunoassays through the utilization of superior materials and advanced detection systems [7].
This article introduces recent developments in various immunoassay methods centered around PCT detection. Notably, nanomaterials have been employed as signal reporter molecules to amplify detection signals [810]. Although the development of nano-biological detection technology is still in its early stages of development, the superior properties of nanomaterials have brought a new dawn to rapid diagnosis. Specifically, semiconductor quantum dots (QDs) [11,12], hydrogels [1316], and graphene [1719] have demonstrated marked advantages in enhancing detection system performance. Furthermore, surface-enhanced Raman spectroscopy (SERS) and digital enzyme-linked immunosorbent assay (digital ELISA) also have offered distinct advantages in improving sensitivity [20,21]. The integration of emerging technologies such as nanotechnology [22,23], biochips [24], and microfluidics in immune detection clinical diagnosis [2528] marked a new stage in PCT detection—characterized by heightened sensitivity and specificity. This convergence of technologies signifies a paradigm shift in the landscape of PCT detection toward more advanced and precise methodologies.
Therefore, this article provides a comprehensive review of the applications of various PCT immunoassay technologies in recent years, including history and recent developments. First, we briefly introduce the background and principles of several major methods such as chemiluminescence, immunofluorescence (IF), enzyme-related immunosorbent, latex-enhanced turbidity, colloidal gold immunochromatography, and radioimmunoassay (RIA) (Fig. 1), and then the detection performance and application prospects of the improved new method are introduced and evaluated. Finally, we summarized the clinical application value of PCT. We have reason to believe that this review has shed new light on the development of PCT immunoassay methods and will provide more inspiration for future research work.
The application of chemiluminescence as an analytical tool dates back to the early 1950s, and since then, various branches related to this technology, such as theoretical concepts, instrumentation, and methods, have experienced important development [2931]. Chemiluminescence, combining the specificity of antigen–antibody immune reactions with the sensitivity of chemiluminescence reactions, is well-suited for detecting various antigens, antibodies, and other biochemical analytes commonly used in clinical detection. As we know, when a substance returns from an electronically excited state to its ground state, the energy released manifests as light. Chemiluminescence labels these luminescent substances, absorbing chemical energy during reactions and releasing it as photons. In the PCT chemiluminescence immunoassay, PCT monoclonal antibodies (mAbs) are coated on a solid-phase carrier, and luminescent substances label PCT mAbs directed against another epitope, forming a double-antibody sandwich structure with a chemiluminescent substrate system. Common luminescent substances include acridinium esters [32], ruthenium terpyridin [33], luminol and its derivatives [3436], and 3-(2′-spiroadamantyl)-4-methoxy-4-(3″-phosphoryloxy)-phenyl-1,2-dioxetane [37]. In recent years, metal nanoparticles have been utilized as catalysts, reducing agents, energy receptors, and nano-response platforms, triggering liquid-phase chemiluminescence reactions due to their special optical, catalytic, and chemical effects. This is important for chemiluminescent biodetection using metal nanoparticles as nanoprobes or nanointerfaces.
In one study, a magnetic nanoparticle (MNP)-based assay was used to determine PCT concentration using chemiluminescent immunoassay (CLIA). This study employed N-(aminobutyl)-N-(ethylisoluminol) (ABEI) as the luminescent substrate, coupled with magnetic particles serving as separators. This combination enhanced the availability of active binding sites, promoting more effective interactions (Fig. 2A). The method achieved a sensitivity of 0.03 ng/ml, surpassing the traditional chemiluminescence method's sensitivity of 0.05 ng/ml. This level of sensitivity is well-suited for clinical applications. Additionally, the meticulous magnetic separation and cleaning process led to a substantial enhancement in detection specificity [38]. Another study showcased a magnetic bead-based electrochemical immunoassay for PCT determination in human serum samples, employing disposable screen-printed carbon electrode (SPE-C) and electro-kinetically driven microfluidic chips with integrated Au electrodes (EMC-Au) methods with varying detection limits (Fig. 2B) [39]. The limit of detection (LOD) is 0.1 ng/ml for SPE-C and 0.04 ng/ml for EMC-Au. Hence, the cutoff value as 0.5 ng/ml was applicable to clinically relevant concentrations of SPE-C and EMC-Au at 0.5 to 1,000 and 0.1 to 20 ng/ml, respectively. An electrochemical immunosensor (EIS) utilizing a CeO2CuO-Au platform, consisting of gold nanoparticle (AuNP)-modified CeO2-CuO, demonstrates large surface area, good biocompatibility, and high activity, enabling enhanced molecule immobilization. Thionine-modified Au@Ag heterojunction nanorods (Au@Ag-Th) were used as signal tags, which provided good active sites for connecting secondary antibodies (Fig. 2C) [40]. Additionally, a bioactive protective electro-chemiluminescent biosensor using gold nanoclusters as luminescent agent and Cu2S snowflakes as synergistic reaction accelerator has also been studied for PCT analysis. Cu2S, known for superior conductivity and a high specific surface area, served as an ideal substrate for immobilizing antibodies and as a promoter for synergistic reactions (Fig. 2D) [41].
Semiconductor nanocrystals offer potential benefits as chemiluminescent emitters, showing ease of multicolor labeling in the visible and near-infrared spectral regions [42,43]. Despite potential toxicity and higher costs, introducing nanomaterials (MNPs, QDs, and carbon nanomaterials) into CL was a crucial strategy for signal amplification and developing various analytical methods. Studies have compared the luminescence properties of common QDs (Fig. 3A) [44]. PbS QDs were utilized as a p-type narrow bandgap semiconductor, while PbS/Co3O4 was used as a signal marker to detect PCT, and signal amplification was achieved through the collective effect of spatial impedance competing with light and electron donors (Fig. 3B) [45]. BiVO4 is an n-type semiconductor with superior performance and poses inherent characteristics such as strong visible light absorption and medium band gap. As an emerging biosensor material, the multi-void nanoarray BiVO4/CuxS system was reported as signal amplification for ultrasensitive photo-immunoassay of PCT (Fig. 3C). Due to the well-matched energy levels between BiVO4 and CuxS, porous nanoarray BiVO4/CuxS electrodes can enhance the separation of e/h+ pairs under visible light irradiation. In addition, BiVO4 porous nanoarrays had a larger specific surface area and more reaction sites, which accelerated the electron transfer rate and thus enhanced the chemiluminescence reaction [46]. Another work combined BiVO4 with 2 narrow bandgap semiconductors to prepare BiVO4/GaON/CdS ternary nanocomposites, leading to improved light absorption capabilities and higher photoelectric conversion efficiency (Fig. 3D). The addition of GaON greatly improved the charge transfer efficiency, and the in situ growth of CdS on BiVO4/GaON composites expanded the light absorption range and further enhanced the chemiluminescence reaction [47]. The toxicity of semiconductors was often associated with their small size, high specific surface area, and unique chemical properties. When these nanocrystals entered the organism, they might interact with biomolecules inside the cell, causing cell damage or dysfunction, but this disadvantage is not serious when tested in vitro. By developing straightforward, cost-effective synthesis methods and establishing optimized production processes and parameters, we aim to achieve large-scale manufacturing of semiconductor nanocrystals, thereby reducing production costs and facilitating their widespread application.
Several studies have employed electronic sensors based on electrolyte-gated organic field-effect transistor (EGOFET) to detect PCT. Specific antibodies were fixed on the surface of poly3-hexylthiophene (P3HT) organic semiconductors in this immunosensor, achieving a remarkably low LOD of 2.2 pM (Fig. 4A) [48]. Chromophore graphitic carbon nitride (g-C3N4) is a metal-free semiconductor nanomaterial known for its stable properties, unique energy band structure, biocompatibility, eco-friendliness, and ease of functionalization. Loading g-C3N4 onto metal-organic frameworks (MOF) materials enhances the ECL signal's strength and stability. The double quenching effect of the luminophore was also utilized to give it specific selectivity (Fig. 4B) [49]. The combination of CdS and other semiconductors could efficiently enhance ECL performance and photocatalytic activity. An ECL immunosensor based on CdS-MoS2 nanocomposite showed high sensitivity, which used H2O2 and K2S2O8 as dual reactants, producing more intense ECL emissions than K2S2O8 or H2O2 as separate reactants (Fig. 4C) [50]. Tin oxide (SnO2) has become a representative semiconductor material due to its unique catalytic and electrochemical properties. A new label-free photoelectrochemical (PEC) immunosensor utilizing SnO2 achieved highly sensitive PCT analysis, which employed SnO2/BiOI/Ag2S composite material with superior photoelectric activity as the substrate. The energy levels of SnO2, BiOI, and Ag2S matched and posed excellent light absorption properties, thus providing a strong and stable signal (Fig. 3D) [51].
Although various nanomaterials primarily function as individual catalysts in chemiluminescence reactions, the mechanisms underlying chemiluminescence enhancement remain unclear and sometimes contradictory. Investigating how nanomaterials of different sizes impact the intensity, wavelength, and kinetics of chemiluminescence represents a crucial avenue for future research in this field. Advanced characterization techniques and time-resolved spectroscopy allow direct observation of the electron transfer processes involving nanomaterials during chemiluminescence reactions. Additionally, quantum chemical calculations and simulations provide an in-depth understanding of electron transfer dynamics and electronic state changes occurring at the surface of nanomaterials. Researchers have also explored the influence of surface properties on chemiluminescence reactions. Developing more accurate theoretical models and computational methods will enable us to predict and explain nanomaterial behavior in chemiluminescence reactions. The enhancement mechanisms of nanomaterials in chemiluminescence reactions constitute an interdisciplinary research field that necessitates collaboration across disciplines such as chemistry, physics, materials science, biology, and computational science. By delving deeply into these areas, we anticipate generating novel ideas and methodologies for applying nanomaterials in the realm of chemiluminescence.
Carbon materials, with advantages like good biocompatibility and low toxicity, were utilized in an innovative 3-dimensional (3D) carbonized wood integrated EIS for ultrasensitive PCT testing. The novel 3D carbon immunosensor consisted of 3D carbonized wood, carboxyl multi-wall carbon nanotubes (CNTs), Au@Co3O4 core-shell nanospheres, and Au single-layer nitrogen-doped graphene. It had abundant interlaced microchannels, which promoted the transfer of reactants and electrons, greatly amplified the current intensity, and enhanced the stability of the electrode (Fig. 5A) [52]. Secondary antibody (Ab2) was immobilized using carbon quantum dots (CQDs) and AuNP coupled polyethyleneimine functionalized graphene oxide (PEI-GO) complexes. Under the combined effect of silver nanoparticles (AgNPs), polydopamine, AuNPs, and PEI-GO, the ECL signal of CQDs was significantly improved. This conductive material enhances electron transmission efficiency, further improving electrochemical sensing performance [53]. There is also a study using graphitic carbon nitride (g-C3N4-CNT@Au) functionalized with CNTs and AuNPs as the donor of ECL. The g-C3N4-CNT@Au showed better performance than pure g-C3N4 and a higher and more stable ECL signal. CuO nanospheres (CuO@PDA) covered with a polydopamine (PDA) layer were used as ECL receptors. A sandwich electrochemiluminescence (ECL) immunosensor based on ECL resonance energy transfer (ECL-ret) was developed for detecting PCT (Fig. 5B) [54]. A AgNp-doped graphene impedance biosensor achieved sensitive detection of PCT. This study utilized cost-effective and environmentally friendly materials, yielding a reusable curve with sensitivity as low as 0.55 ng/ml. The sensitivity was due to the uniform and huge surface area of single-layer graphene (SLG) and AgNp (Fig. 5D) [55]. Additionally, a label-free ultrasensitive electrochemical sensor based on graphite nitride nanosheets (g-C3N4 NS) was used to detect PCT. The probe peptide (PP) is connected to the electrode surface through π-π stacking between g-C3N4 NS and phenylalanine at the end of the peptide, providing efficient electrochemical solutions for ultrasensitive detection of PCT (Fig. 5C) [56]. An ultrasensitive sandwich electrochemical method was employed for PCT testing. First, a reduced graphene oxide (rGO)–gold (Au) nanocomposite film was assembled as an immunosensor to improve the immobilization of PCT antibody 1 (Ab1). Next, single-walled carbon nanohorns/hollow platinum chains complexes labeled with PCT Ab2 served as signal tags [57]. Another study enabled simultaneous detection by combining a nanocomposite surface composed of cross-linked bovine serum albumin with a reduced graphene oxide nanoparticle structure that not only protects against biological contaminants but also maintains conductivity for multiple sepsis biomarkers [58].
Compared to single-analyte immunoassays, multiplexed analysis emerges as a promising trend in sample analysis. Recently, CLIA has been employed for multiplexed analysis on microfluidic chips. A newly developed PCT diagnostic kit utilized a one-step sandwich CLIA approach for quantitative detection of serum concentration of PCT using the HYBIOME e-180 system. Achieving a low LOD of 0.0075 ng/ml, the within- and between-kit coefficient of variation ranged from 0.8% to 3.9%, and the detection range is 0.01 to 110 ng/ml [59]. An ideal hyperbolic microfluidic chip (DHMC) was employed for the sensitive detection of the inflammatory marker PCT via chemiluminescence signal. It is simply achieved through mixing of specimens to be tested and detection reagents (Fig. 6B); this approach offered enhanced precision [60]. Another innovative method involved a CLIA based on active droplet array microfluidics, enabling rapid PCT detection within 12 min (Fig. 6A) [61]. Using a polyolefin microfluidic chip prepared through a silicon master mold hot pressing method, disease biomarkers, including C-reactive protein (CRP) in the same class as PCT, were detected in human serum (Fig. 6C) [62]. Additionally, a polydimethylsiloxane (PDMS) microfluidic chemiluminescence device with signal amplification capability, featuring a double-helical flow channel, was developed for specific detection of human immunoglobulin G (IgG), and it was generalizable in PCT testing (Fig. 6D) [63]. The future of microfluidic chips hinges on portability, integration, and automation development, facilitating the automation of CLIAs.
IF, an early development in labeling immune technology, is a recognized quantitative immune detection method. The fluorescent substances that can be used as markers should produce obvious fluorescence and do not affect the binding activity of antigens and antibodies. The commonly seen options include fluorescein isothiocyanate, tetraethyl rhodamine, tetramethyl rhodamine isothiocyanate, 4-methylumbelliferone-β-D galactopyranoside, and lanthanide metals. It can be divided into direct fluorescence (DIF) and indirect fluorescence (IIF) subtypes. DIF makes use of fluorescent labeled antibodies to directly bind to the target antigen [64]. IIF often adopts a 2-step route, in which an unlabeled primary antibody binds to the antibody target followed by detecting it via a fluorophore labeled second antibody. The extra binding step promises high sensitivity due to the further amplification of the fluorescence signal, compensating for its complexity and being time-consuming [65,66]. Quantitative immunofluorescence assay (IFA) is cost-effective, rapid, and user-friendly, and offers improved diagnostic capabilities for detecting PCT. Its detection range is 0.1 to 100.0 ng/ml [67].
To meet the growing demand for point-of-care (POC) PCT detection in clinical applications, a micromotor-based fluorescence immunoassay was developed for PCT testing. The lowest detection limit achieved was 0.07 ng/ml, with a detection concentration range of 0.5–150 ng/ml, and requiring only 25 μl of sample (Fig. 7C); this technology addressed the need for high sensitivity [68]. Signal intensity in immunofluorescence detection could be enhanced by over 9 times through circulating staining with secondary antibodies (Fig. 7A and B) [69]. A fluorescence amplified PCT biosensing system uses nanocapsules and magnetic carbon dots. Nanocapsules ensured the effective encapsulation of nanoparticles and prevented leakage, and also greatly improved the enrichment ability of fluorescent nanoparticles to amplify the fluorescence signal. This strategy enables trace-level quantification of PCT within a detection range of 1 to 1,000 pg/ml (Fig. 7D) [70]. In PCT detection, paired mouse mAbs were usually used to bind to 2 different antigen binding sites, thereby forming a sandwich complex. When fixing the fluorescent labeled antibody on the testing tube wall, the content of the PCT marker reflected by a luminous reagent can be obtained quantitatively with comparison to the standard curves. Like chemiluminescence, immunofluorescence emits light due to the transition of molecular energy level back to the ground state; meanwhile, the fluorescence needs to provide an external light source, that is, photoluminescence. Ultraviolet light is usually used as an external light source. Upon absorbing it, the substance emits fluorescence in the visible band.
However, compared with the common fluorophore whose emission wavelength is in the ultraviolet (UV) region, the fluorescein secondary antibody in the near-infrared region (NIR) has a higher signal-to-noise ratio and other important advantages. NIR fluorophore with high chemical stability, light stability, strong target specificity, and high fluorescence brightness has been developed, which is expected to enter clinical applications in the future [71]. A recent work introduces a AuNP-assisted immunofluorescence method, utilizing a second antibody functionalized dye in a sandwich structure assembly with antibody-functionalized AuNPs and antigens. It can realize specific and sensitive detection of biomarkers without the phenomenon of front and back banding. In addition, the method does not require sample handling and washing steps, which greatly saves detection time. This homogeneous multicomponent fluorescence method significantly improves sensitivity and dynamic range [72], though its application to PCT detection has not yet been explored.
In 1971, ELISA was initially proposed for quantifying IgG-type immunoglobulins. ELISA, a direct or indirect method for detecting antigens or antibodies, involves attaching them to the surface of micropores (Fig. 8A) [73,74]. Different detection methods, including direct ELISA (antigen screening), indirect ELISA, sandwich ELISA (antibody screening), and competitive ELISA (antigen/antibody screening) (Fig. 8C), were employed based on detection conditions and specific sample requirements [75]. Typically, the specific antibody was coated on the enzyme-labeled substrate and the antigen was added to the coated antibody and bound. After washing away unbound substance, another specific antibody labeled with enzyme was introduced for detection. The presence of analytes can be determined and quantified by the color changes from enzyme-linked conjugates and enzyme substrates. The specific antibody–antigen interaction promised high sensitivity at picomolar to nanomolar ranges (10−12 to 10−9 mol/L). Besides PCT, the majority of known inflammatory cytokines are also detectable and quantified with ELISA. For example, the cytokine spectrum of sepsis-infected persons tracked by ELISA helps facilitate understanding of the inflammatory changes [76]. Considering the complexity of ELISA operation steps often bringing in diverse interfering factors, a growing number of studies are aimed at simplifying these steps to reduce the influence of interfering and crosstalk issues.
The application of a streptavidin system in ELISA plays an important role in signal amplification, which has been proven to increase the number of lapels per sandwich by 3-fold [7779]. Traditional ELISAs require long incubation times and laborious multi-step washing processes, making them inefficient and laborious. In the realm of nanotechnology in biomedicine, nanoparticles act as carriers to assist immunoassays, greatly enhancing sensitivity, simplicity, and specificity of detection [80]. For example, magnetic nanoenzyme-linked immunosorbent assay (MagLISA) combined silicon-shell MNPs and AuNPs to achieve analyte separation and enzymatic activity amplification of gold nanoenzymes (AuNZs) with ultrasensitivity (Fig. 8B) [81]. Since AuNPs have a high surface area, they can be easily coupled with biomolecules to prepare dual-labeled AuNP probes, and a detection antibody coupled with multiple HRPs on AuNPs greatly improved the detection signal. It can be directly used for PCT detection in human serum with a sensitivity of 20 pg/ml [7]. A reported sandwich ELISA for PCT quantification in equine plasma samples operated within a range of 25 to 1,000 ng/ml [82]. A rod-shaped magnetically driven nanorobot served as an operable immunoassay probe, facilitating automated and efficient ELISA analysis strategies. In gradient magnetic fields and rotating magnetic fields, directional uniform mixing was achieved, shortening incubation time and improving detection efficiency (Fig. 8D) [83].
To achieve a low LOD, a proposed fluorescence detection system employed alkaline phosphatase (ALP) as the marker enzyme and copper nanoclusters (CuNCs) as the tracer agent. This system, utilizing human IgG as the standard antigen, established a reliable detection range of 0.05 to 12 ng/ml, a much lower detection limit compared to previously reported ELISA methods [84]. Fluorescence-based oligonucleotide-linked immunosorbent assays and fluorescence-based oligonucleotide-linked immunospots provided highly multiplexed methods with signal amplification using DNA-barcoded antibodies. Signal enhancement and multi-objective simultaneous detection were successfully carried out through DNA complementary pairing and modular orthogonal DNA tandems [85]. Further data analysis indicated that ELISA outperformed IIF in detecting autoantibodies [86].
Monitoring minute changes in PCT and other protein marker concentrations are of great value in clinical diagnosis and pathological research. The increasing demand for ultrasensitive and multiplexed protein detection has increased the development speed of digital immunoassay technology (Fig. 9A). Specifically, traditional (analog) ELISA cannot accurately quantify, whereas digital ELISA can calculate the average number of enzyme molecules per bead at a given sample concentration, with the red grid representing the lowest detectable concentration of the target protein in both analog and numerical methods [87]. Microfluidic systems form the basis of digital immune analysis, with relevant research already underway [21]. For instance, a microfluidic ELISA chip-based POC assay detected protein markers with a detection limit as low as 0.0005 μg/ml, demonstrating good reproducibility in intra-test (5.1%) and between-test (9.3%) CV values [88]. The hierarchical structure microchip POC immunoassay offered an adjustable detection range and could realize multiplex detection of biomarkers (Fig. 9B) [89]. A study introduced a tape-based key valve microfluidic chip (KVMC) system capable of simultaneously detecting multiple biomarkers other than PCT. A single button valve was employed to adjust the mixing and sequence of multiple reagents, resulting in higher detection efficiency and integration. The entire test was conducted in a portable automated device, meeting the need for POC testing (POCT) of infections (Fig. 9C) [90]. A waveform microfluidic chip (WMC)-assisted multiplex detection system was utilized, involving premixing of antigens and detection antibodies in a micromixer. This approach simplified incubation and washing steps, ultimately reducing the overall detection time and enhancing reproducibility through optimization and preprocessing (Fig. 9D) [91]. Microfluidic technology significantly improved the diagnostic accuracy of ELISA, reducing the disease burdens and playing a crucial role in the field of precision medicine.
AuNPs are renowned for their superior chemical stability and size-dependent optical properties [92]. Immune colloidal gold was developed as a lateral flow immunochromatography assay (LFIA) determination technology, integrating the double antibody sandwich principle [9395]. In clinically applied immunochromatography, the lowest reported detection limit for PCT is approximately 0.1 ng/ml. Despite providing fast (usually less than half an hour) and simple PCT detection, achieving quantitative results remains a challenge [96]. A gold-based paper sensor designed to detect PCT in clinical samples demonstrated a detection limit of 0.1 ng/ml and a detection range from 0.49 to 13.90 ng/ml (Fig. 10A) [97]. To enhance sensitivity, researchers explored increasing the size of AuNPs. Studies indicated that larger-sized AuNPs have higher optical intensity, but excessive size diminished sensitivity due to reduced diffusivity and stronger light scattering. Small-size (12 nm) hydrophobic AuNPs were found to self-assemble into large-size (100 to 400 nm) gold superparticles (GSPs), demonstrating strong light absorption and extremely weak light scattering, achieving quantitative detection with improved sensitivity (Fig. 10B) [93].
A study has developed a composite nanomaterial based on colloidal gold–colloidal gold enhancer (CGE). Colloidal gold and CGE served as tracers, labeling antibodies to form immunoprobes for subsequent serum PCT qualification. The absorption coefficient of CGE at 520 nm was found to be approximately 10 times that of colloidal gold immunoprobes, significantly improving the sensitivity of detecting PCT [98]. Another study confirmed the high sensitivity of CGE immunoprobe detection, with detection limits of 0.5 ng/ml for colloidal gold and 0.025 ng/ml for CGE immunoprobes. Notably, the CGE immunoprobe demonstrated a sensitivity 20 times higher than that of the colloidal gold immunoprobe [98]. Additionally, a “three-in-one” multifunctional catalytic colorimetric nanohybrid (Fe3O4@MOF@Pt) composed of Fe3O4 nanoparticles, MIL-100 (Fe), and platinum (Pt) nanoparticles overcame the signal intensity limitation of AuNPs in colorimetric assays. It exhibited high colorimetric signal brightness and ultra-high peroxide simulation activity, and achieved a rapid magnetic response approximately 2,280 times more sensitive than normal LFIA. It overcomes the shortcoming of insufficient colorimetric signal intensity of AuNPs and achieves ultrasensitive analysis of PCT on an immunochromatography platform (Fig. 10D) [99]. Besides composite materials, studies have explored different types of AuNPs, such as gold nanospheres (GNSs), gold nanopopcorns (GNPNs), and gold nanostars (GNSTs), using them as markers in immunochromatography. They both exhibited enhanced stability due to a complex 3-dimensional structure. Furthermore, their spherical shape and vast surface area facilitated the presence of surface-bound antibodies, thereby increasing the detection sensitivity. Importantly, this system requires no additional steps, thereby avoiding extra consumption of antibodies. The silver enhancement method was employed to improve sensitivity. This method's sensitivity for detecting PCT was 10 times that of the conventional colloidal gold immunochromatographic assay labeled with gold nanospheres (Fig. 10C) [100].
A PCT assay utilizing a biotin–streptavidin system enhanced transverse flow immunoassay. The amplification of the analysis signal resulted from the accumulation of AuNP clumps [101]. Another platinum staining method based on a test strip retained the original properties of colloidal gold while leveraging platinum nanoparticles (PTNPs) with good catalytic activity as a signal label, achieving sensitive and quantitative testing [102]. In addition to gold nanomaterials, studies also have explored lanthanide chelates as fluorescent markers for lateral flow immunoassays. Carboxylic acid-modified europium (III) (Eu (III)) chelate particles were used to manufacture immunochromatography test strips, exhibiting a narrow emission spectrum and a wide excitation spectrum (613 nm and 333 nm). Combined with a portable time-resolved fluorescence reading system, this approach offered a broader linear range, and greater sensitivity and accuracy, enabling instant POCT detection (Fig. 11A) [103]. In another work, lanthanide chelates encapsulated polystyrene nanoparticles for rapid quantitative immunochromatographic analysis of PCT, shortening the detection time to 15 min (Fig. 11B) [104]. An immunochromatography-based upconversion luminescence (UCL) system utilized mesoporous silica-encapsulated upconversion nanoparticles (UCNPs@mSiO2) as probes. The biocompatibility and strong luminescence intensity of UCNPs@mSiO2 made it an ideal choice for the quantitative analysis of PCT in plasma (Fig. 11C) [105].
The development of colloidal gold immune technology has overcome the limitations of traditional colloidal gold strips, addressing issues such as low sensitivity and non-quantification. SERS has extended the application of colloidal gold, demonstrating marked signal amplification when Raman signal molecules were labeled on the colloidal gold surface (Fig. 12A) [106,107]. This characteristic allows for quantitative or semi-quantitative detection of PCT. In a particular study, dual-channel detection was achieved by embedding 2 different Raman reporter molecules in the Au@Ag shell. Simultaneously, magnetic beads facilitated rapid capture [108]. However, this method has not been applied in immunochromatography, considering introducing complexities to the detection process. Due to the low stability of nanoparticles labeled with Raman reporter molecules, an in situ Raman enhancement (i-SERS) method was developed. This method, generating SERS signals on AuNPs, not only retained the previous advantages of colloidal gold strips but also achieved better sensitivity and quantitative detection results, which results in a sensitivity of 0.03 ng/ml and a turnaround time of 16 min (Fig. 12B) [109]. There is also a work that combines SERS with immunochromatography to establish a dual-pathway detection immunochromatography. IL-6 antibodies and PCT antibodies were coupled to gold nanocages respectively as SERS markers. With the addition of IL-6 and PCT, the reactants were captured on the 2 test articles. The special structure of graphene nanoclusters rich in biological binding sites and hot spots endows the system with extremely high SERS performance (Fig. 12C) [110]. Utilizing gold nanoflowers as labels in an immunochromatographic detection method based on photometry and SERS (Fig. 12D) [111]. Although the combination of SERS with immunochromatography offered obvious advantages for detecting PCT, it also led to complexities to some extent. These include challenges related to technology integration, substrate stability, multiple detection targets, instrument costs, operational intricacies, and issues with background interference and signal enhancement. However, as technology continues to progress and optimization efforts persist, it is anticipated that these challenges will be overcome. Consequently, this will further facilitate the application and development of SERS in the field of immunochromatography.
Fluorescent microsphere (FM) immunochromatography has emerged as an alternative to address issues of poor sensitivity and non-quantification. A fluorescent metal-AIEgen framework (MAFs) has 2 functions: protein detection and bacterial identification. With a large surface area, excellent photostability, and multiple active sites for protein binding, MAF enabled ultrasensitive detection of multiple biomarkers in lateral flow immunoassays. Its detection sensitivity for PCT is 0.333 pg/ml, offering promising application prospects in POCT for bacterial infections (Fig. 13A) [112]. In another approach, aggregated luminescent microspheres replaced organic fluorescein dye-embedded FMs, overcoming aggregation-induced quenching and Stokes shift defects. This approach held great potential to optimize detection performance of immunochromatography platforms, as depicted in Fig. 13B to D [113,114]. Additionally, highly luminescent quantum dot beads (QBs) were prepared as an alternative to AuNPs. The fluorescence intensity of each QB was approximately 900 times that of the QD. It can be used for quantitative detection of serum PCT. Its detection limit was approximately 10 times lower than traditional AuNPs immunochromatography methods [115]. To reduce cost, rapid immunochromatographic test strips with colloidal carbon and quantum dot microspheres (QDMs) as labels have been developed. The test strip, equipped with a smart reader and mAb probe, offers fast detection, simple operation, and cost-effectiveness [11,116,117]. There is research employing fluorescent carbon dots/SiO2 nanospheres for lateral flow assay (LFA). Carbon colloids and CNTs served as signal reporters, providing enhanced sensitivity, stability, and environmental friendliness. Although not yet applied to PCT detection, there is optimism about its broad application prospects [117]. Additionally, a handheld FM-based PCT detection system has been developed, enabling test strips with a wide detection range and a low LOD. This method ensured accurate detection of PCT concentration in human serum within 12 min, with long-term storage stability exceeding 12 months (Fig. 11C) [118].
Overall, MAFs exhibit excellent fluorescence properties, enabling highly sensitive detection. On the other hand, AIEgen emits light selectively under specific conditions, making it useful for detecting target molecules in complex biological samples. However, it is worth noting that MAFs may not be as stable as other FMs, especially under certain conditions. Their synthesis typically involves multi-step reactions and precise control conditions, adding complexity to the preparation process. QB stands out due to its high fluorescence brightness, particularly advantageous for detecting low-concentration analytes. Additionally, the size of QB can be controlled during synthesis to tailor its fluorescence properties. However, it is essential to recognize that while QDs are generally more stable and less affected by environmental factors than organic dyes, they can be potentially toxic and lack biocompatibility. QDM, with its larger size, facilitates separation and purification from solution. Integrating multiple QDs within a single microsphere enhances the fluorescence signal and improves detection sensitivity. Structurally, QDM tends to be more stable than standalone QDs. Nevertheless, achieving uniform fluorescence properties in QDM may involve complex processes and rigorous quality control. When choosing a fluorescence microsphere detection platform, consider specific requirements for PCT detection, including sensitivity, selectivity, stability, biocompatibility, and preparation complexity.
Immunoturbidimetry, a dynamic monitoring method for detecting antigen and antibody complexes, has various applications, including immune transmission turbidimetry, immune scattering turbidimetry, and immune latex turbidimetry [119121]. Immunoturbidimetry offered both rate scattering turbidimetry and endpoint scattering turbidimetry. The former is a dynamic detection method providing real-time scattering light intensity of antigen–antibody complexes, while the latter measures the reaction equilibrium as the total amount of antigen–antibody complexes [122]. Although traditionally employed for detecting more abundant CRP in serum due to its poor sensitivity, efforts are needed to improve sensitivity [123]. Particle-enhanced turbidimetric immunoassay emerged for determining analytes with relatively low concentrations, achieving quick detection on automatic biochemical analyzers. Latex particle-enhanced turbidity immunoassay is considered a reliable and easy-to-implement tool [124,125].
A standardized immunoassay reagent based on latex immunoturbidimetry for quantitative CRP detection has been developed, detecting CRP in a broad range of 0.2 to 320 mg/L and an accuracy exceeding 99%. Furthermore, a particle-enhanced turbidity immunoassay based on viral nucleocapsids has been designed to quantify immune responses to the virus, as depicted in Fig. 14D [126]. Another study introduced a microparticle turbidimetric reagent with high colloidal stability, utilizing immunopurified polyclonal antibodies. This approach allowed for lower antibody coverage on the particulate reagent, eliminating the drawbacks of non-specific agglutination in light scattering immunoassays and enhancing the colloidal stability of the reagent [127]. In addition to microparticles, there is also an ultrasensitive method called nanoplasmonic immunoturbidimetry assay. The increase in nanoparticle size induced a change in optical extinction or density value, which is measured at a certain wavelength with a universal microplate reader on the nanosensor chip. This improvement surpassed conventional immunoturbidity detection by more than 1,000 times. Not only can CRP be detected within a wide linear range of 1 to 500 ng/ml, the detection limit is reduced to 0.54 ng/ml, and the detection time only needs to be within 10 min. Because it is highly sensitive and effective in blood tests, this may become a novel technical system for detecting other biomarkers, including PCT (Fig. 14A and C) [128,129].
Microfluidic technology plays a crucial role in immune turbidity detection systems. Immunoturbidimetry, a quantitative analysis method based on antigen–antibody reactions, determines the concentration of antigens or antibodies in a sample by measuring the change in turbidity during the reaction. Microfluidic technology allows precise control of fluid flow in microchannels during immunoturbidimetric detection, facilitating rapid mixing, dilution, and sample separation. This enhances analysis speed and efficiency while reducing sample and reagent consumption, minimizing background interference, and improving detection accuracy. Additionally, microfluidic systems exhibit high integration and automation capabilities [130,131]. A research work proposed a new portable immunoturbidimetric detection system based on multi-layer centrifugal microfluidics, which precipitated blood cells in real time through centrifugation and quantitatively extracts purified plasma through a siphon valve. A real-time standard curve can be integrated on the chip. Since each test is individually calibrated, the interference from various environmental factors and manufacturing processes was greatly reduced, resulting in small error fluctuations. The experimental results are the same as those of the fully automatic biochemical analyzer. This research is expected to enable simultaneous detection of multiple specific proteins (Fig. 14B) [132]. Another research introduced a quantitative immune-agglutination analysis of a microvolume turbidity system integrating microfluidic technology. The system held promise in clinical diagnosis, particularly for small sample volume [133135]. However, the consumables of microfluidic chips, such as test tubes and optical systems, can be expensive. A subsequent innovative turbidity determination system for quantitative immune-agglutination assays was constructed using off-the-shelf components. This system replaced disposable glass capillaries with inexpensive test tubes. The proximity extension assay (PEA), a homogeneous, dual-recognition immunoassay, demonstrated sensitivity, specificity, and convenience in detecting or quantifying one or more analytes in human plasma. The sensitivity of PCT in plasma samples was approximately 0.1 ng/ml [136,137]. Immune turbidimetry faced challenges, including excessive antibody requirements due to the hook effect between antigen and antibody, resulting in a narrow detection range. Additionally, immunoturbidimetry results were susceptible to sample quality issues, such as lipid blood, hemolysis, and jaundice interfering with absorbance signals.
RIA was developed to address these challenges by introducing a radioisotope-labeled antigen and unlabeled antigen to competitively bind antibodies [138,139]. Hence, the intensity of radiation is related to the amount of antigen measured. This quantitative method exhibited high sensitivity, usually reaching picomoles within a small number of samples. However, RIA uses radioactive isotopes that can be harmful to the human body. Furthermore, the technology required expensive equipment and consumables, limiting its application for PCT or other biomarkers.
Despite these limitations, RIA offered extremely high sensitivity and specificity. A study using RIA to measure calcitonin levels in rats demonstrated sufficient sensitivity with a range of 0.15 to 0.25 ng/ml [140]. Some studies indicated that liquid-phase RIA was more sensitive than solid-phase ELISA, IF, and endomysium antibodies (EMA) methods for specific autoimmune assays [141]. A microfluidic chip for RIA (μ-RIA) was designed for automated and high-throughput detection (Fig. 15A) [142]. However, due to poor specificity caused by polyclonal antibodies, it struggled to accurately distinguish free PCT, bound PCT, and PCT-related peptide precursors. In addition, the long turnaround time and the risks associated with radioactive substances limited the scope of RIA. To address the challenges posed by radioactive isotopes in RIA, metal stable isotope labeling may offer an alternative for biomolecule quantitation. With the advancement of atomic mass spectrometry measurement methods for metal stable isotopes, inductively coupled plasma mass spectrometry stood out for its excellent sensitivity, wide dynamic linear range, and multiple and accurate quantitative capabilities (Fig. 15B) [143]. However, the stability of metal stable isotope markers may be a concern, potentially leading to decomposition or inactivation and affecting detection results. In conclusion, representative innovative methods from each type were selected, and a table was created to summarize and compare them (Table).
In clinical practice, assessing serum PCT concentration aids in identifying bacterial infections. Notably, a substantial increase in serum PCT is indicative of systemic reactions caused by bacterial infections, distinguishing them from other causes like autoimmune diseases, inflammation, and viral infections, where PCT levels typically remain low [144146]. A typical study suggested an association between PCT concentrations and infective endocarditis, advocating for a lower PCT threshold to rule out endocarditis in routine clinical practice [147]. It is essential to highlight that PCT exhibited a rapid increase in severe bacterial infections within a few hours, offering an advantage over other inflammatory factors for early diagnosis [148]. Moreover, monitoring PCT changes allows for assessing the severity of bacterial infections and identifying the type of pathogenic microorganisms [149,150].
In addition, PCT can be used to distinguish between infectious and non-infectious causes of adult respiratory distress, and to distinguish between infectious necrosis and aseptic necrosis of pancreatitis [151]. In hematologic oncology, PCT also helps to make a definitive diagnosis of systemic infections caused by bacteria and fungi. PCT can reliably detect and assess sepsis infection even in chemotherapy patients. It can also be used to monitor infections after organ transplantation, especially those that arise during the rejection phase [152]. Many diseases are not specific in preterm infants and newborns, and PCT can also be used to diagnose and evaluate the treatment effect of these diseases [153].
PCT serves as a classic diagnostic indicator for sepsis [154,155]. Clinical analysis has demonstrated that a blood PCT concentration exceeding 2 ng/ml can diagnose sepsis caused by bacterial infection [156]. Additionally, PCT monitoring enabled distinguishing the infectious course of sepsis [157159]. PCT plays a crucial role in guiding the rational use of antibiotics, aiming to reduce antibiotic misuse [157,160162]. In clinical practice, it is recommended to discontinue antibiotics when the serum PCT is <0.25 ng/ml. If PCT content decreases by over 80% from the maximum value or falls into the range of 0.25 to 0.5 ng/ml, discontinuation of antibiotics is also advised. Conversely, when the PCT level exceeds 0.5 ng/ml and continues to rise, suggesting potential bacterial resistance, changing the antibiotic type is strongly recommended [155,158,163].
The clinical application of PCT holds significant value, and various detection methods have emerged as powerful tools in clinical practice, especially with the growing interest in immunofluorescence and chemiluminescence. Immunoassay technology, renowned for its high specificity, sensitivity, and stability, has found widespread use in clinical diagnosis and biomedical research. In this review, we first introduced the fundamental concepts of PCT and PCT immunoassay to elucidate their basic principles and clinical importance. Then, we briefed several commonly used detection methods, including chemiluminescence, immunofluorescence, enzyme-linked immunoadsorption, latex-enhanced turbidimetry, colloidal gold immunochromatography, and RIA. We also summarized innovative implementation methods developed based on conventional approaches. From an alternative perspective, the research and development directions of immunoassay into magnetic bead immunoassay, Raman spectroscopy detection technology, nucleic acid immunoassay technology, and microfluidic immunoassay were categorized.
Despite distinct technological advancements and the application of new materials with superior properties, achieving early, sensitive detection, and dynamic monitoring during treatment remains challenging [164,165]. While remarkable developments have occurred in this field, challenges persist in achieving universal clinical applications, creating a gap between scientific experimental methods and practical techniques for solving real-world problems. Improvements are necessary in specificity, as actual samples like serum inevitably contain different biomarkers or inhibitors, leading to false-positive and false-negative results. Reagent stability and luminescence in tedious processes also require careful evaluation. Efficient procalcitonin tests (PCTS) have emerged as an alternative method, overcoming the time-consuming nature of blood culture and rapidly identifying bacterial infections [166,167]. PCT detection has matured with various modes, including non-background chromatography [168], surface-enhanced Raman spectroscopy with more obvious signal amplification [169], matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [170], polymerase chain reaction nucleic acid amplification technology, isothermal rolling loop amplification technology at room temperature, etc. [171,172].
In short, despite these technical challenges, emerging technologies and functional materials will continue to contribute to technological innovation with highly sensitive and specific detection methods. Examples include signal reporting factors and real-time counting for single-molecule detection based on nanomaterials as carriers, catalytic compounds, and biosensors [99,173,174]. We anticipate that the scientific community will further promote its development, leading to new applications in the field of immunoassay.
The authors declare that human or animal ethics approval was not needed for this study.
  • National Natural Science Foundation of China (22307098)
  • Zhejiang Provincial Natural Science Foundation of China(LGF22C100003)
  • Wenzhou high-level innovation team(Development and application team of functional liver cancer-on-a-chip)
  • Wenzhou Basic Research Projects(Y2023147)
  • Wenzhou Institute, University of Chinese Academy of Sciences(WIUCASQD2021012)
  • the Scientific and Technological Innovation Major Base of Guangxi(No.2022-36-Z05)
1.
Amanai E, Nakai K, Saito J, Hashiba E, Miura T, Morohashi H, Sakamoto Y, Mikami A, Hakamada K, Hirota K. Usefulness of presepsin for the early detection of infectious complications after elective colorectal surgery, compared with C-reactive protein and procalcitonin. Sci Rep. 2022;12(1):3960.
2.
Kong D, Lei Z, Wang Z, Yu M, Li J, Chai W, Zhao X. A novel HCP (heparin-binding protein-C reactive protein-procalcitonin) inflammatory composite model can predict severe acute pancreatitis. Sci Rep. 2023;13(1):9440.
3.
Xiang Y, Lu J, Mao C, Zhu Y, Wang C, Wu J, Liu X, Wu S, Kwan KYH, Cheung KMC, et al. Ultrasound-triggered interfacial engineering-based microneedle for bacterial infection acne treatment. Sci Adv. 2023;9(10):eadf0854.
4.
Póvoa P, Salluh JIF. Biomarker-guided antibiotic therapy in adult critically ill patients: A critical review. Ann Intensive Care. 2012;2(1):32.
5.
Meisner M. Update on Procalcitonin measurements. Ann Lab Med. 2014;34(4):263–273.
6.
Hubl W, Krassler J, Zingler C, Pertschy A, Hentschel J, Gerhards-Reich C, Mack M, Demant T. Evaluation of a fully automated procalcitonin chemiluminescence immunoassay. Clin Lab. 2003;49(7–8):319–327.
7.
Liao T, Yuan F, Yu H, Li Z. An ultrasensitive ELISA method for the detection of procalcitonin based on magnetic beads and enzyme-antibody labeled gold nanoparticles. Anal Methods. 2016;8(7):1577–1585.
8.
Tong S, Zhu H, Bao G. Magnetic iron oxide nanoparticles for disease detection and therapy. Mater Today. 2019;31:86–99.
9.
Xu T, Chi B, Wu F, Ma S, Zhan S, Yi M, Xu H, Mao C. A sensitive label-free immunosensor for detection α-fetoprotein in whole blood based on anticoagulating magnetic nanoparticles. Biosens Bioelectron. 2017;95:87–93.
10.
Yang W, Yu Y, Shou X, Zhang D, Liang G, Zhao Y. Hedgehog-inspired magnetic nanoparticles for effectively capturing and detecting exosomes. NPG Asia Mater. 2021;13(1):78.
11.
García De Arquer FP, Talapin DV, Klimov VI, Arakawa Y, Bayer M, Sargent EH. Semiconductor quantum dots: Technological progress and future challenges. Science. 2021;373(6555):eaaz8541.
12.
Zhou W, Coleman JJ. Semiconductor quantum dots. Curr Opin Solid State Mater Sci. 2016;20(6):352–360.
13.
Li F, Lyu D, Liu S, Guo W. DNA hydrogels and microgels for biosensing and biomedical applications. Adv Mater. 2020;32(3):1806538.
14.
Du Y, Li C, Zhang Y, Xiong W, Wang F, Wang J, Zhang Y, Deng L, Li X, Chen W, et al. In situ-activated phospholipid-mimic artemisinin prodrug via injectable hydrogel Nano/microsphere for rheumatoid arthritis therapy. Research. 2022;2022:0003.
15.
Chen L, Yang J, Cai Z, Huang Y, Xiao P, Chen H, Luo X, Huang W, Cui W, Hu N. Mitochondrial-oriented injectable hydrogel microspheres maintain homeostasis of chondrocyte metabolism to promote subcellular therapy in osteoarthritis. Research. 2024;7:0306.
16.
He J, Chen C, Chen L, Cheng R, Sun J, Liu X, Wang L, Zhu C, Hu S, Xue Y, et al. Honeycomb-like hydrogel microspheres for 3D bulk construction of tumor models. Research. 2022;2022: 9809763.
17.
Goldoni R, Farronato M, Connelly ST, Tartaglia GM, Yeo W-H. Recent advances in graphene-based nanobiosensors for salivary biomarker detection. Biosens Bioelectron. 2021;171: 112723.
18.
Prattis I, Hui E, Gubeljak P, Kaminski Schierle GS, Lombardo A, Occhipinti LG. Graphene for biosensing applications in point-of-care testing. Trends Biotechnol. 2021;39(10):1065–1077.
19.
Jia D, Li X, Chi Q, Low J, Deng P, Wu W, Wang Y, Zhu K, Li W, Xu M, et al. Direct electron transfer from upconversion graphene quantum dots to TiO2 enabling infrared light-driven overall water splitting. Research. 2022;2022: 9781453.
20.
Chen R, Du X, Cui Y. Vertical flow assay for inflammatory biomarkers based on nanofluidic channel array and SERS nanotags. Small. 2020;16(32):2002801.
21.
Chavez-Pineda OG, Rodriguez-Moncayo R, Cedillo-Alcantar DF, Guevara-Pantoja PE, Amador-Hernandez JU, Garcia-Cordero JL. Microfluidic systems for the analysis of blood-derived molecular biomarkers. Electrophoresis. 2022;43(16–17):1667–1700.
22.
Papafilippou L, Claxton A, Dark P, Kostarelos K, Hadjidemetriou M. Nanotools for sepsis diagnosis and treatment. Adv Healthc Mater. 2021;10(1):2001378.
23.
Li X, Li X, Yang J, du Y, Chen L, Zhao G, Ye T, Zhu Y, Xu X, Deng L, et al. In situ sustained macrophage-targeted nanomicelle–hydrogel microspheres for inhibiting osteoarthritis. Research. 2023;6:0131.
24.
Singh N, Ali MA, Rai P, Sharma A, Malhotra BD, John R. Microporous nanocomposite enabled microfluidic biochip for cardiac biomarker detection. ACS Appl Mater Interfaces. 2017;9(39):33576–33588.
25.
Jones A, Czarnecki P, Dhanapala L, Rusling JF. Multiplexed protein biomarker detection with microfluidic electrochemical immunoarrays [Internet]. In: Whittaker KC, Huang R-P, editors. Antibody arrays. New York, (NY): Springer US; 2021. p. 69–82.
26.
Wang X, Jia J, Niu M, Li W, Zhao Y. Living Chinese herbal scaffolds from microfluidic bioprinting for wound healing. Research. 2023;6:0138.
27.
Yu Y, Guo J, Sun L, Zhang X, Zhao Y. Microfluidic generation of microsprings with ionic liquid encapsulation for flexible electronics. Research. 2019;2019: 6906275.
28.
Wu Z, Sun L, Chen H, Zhao Y. Bioinspired surfaces derived from acoustic waves for on-demand droplet manipulations. Research. 2023;6:0263.
29.
Zhao L, Sun L, Chu X. Chemiluminescence immunoassay. TrAC Trends Anal Chem. 2009;28(4):404–415.
30.
Xiao Q, Lin J-M. Advances and applications of chemiluminescence immunoassay in clinical diagnosis and foods safety. Chin J Anal Chem. 2015;43(6):929–938.
31.
Woodhead JS, Weeks I. Chemiluminescence immunoassay. Pure Appl Chem. 1985;57(3):523–529.
32.
Weeks I, Beheshti I, McCapra F, Campbell AK, Woodhead JS. Acridinium esters as high-specific-activity labels in immunoassay. Clin Chem. 1983;29(8):1474–1479.
33.
Gorman BA, Francis PS, Barnett NW. Tris(2,2′-bipyridyl)ruthenium (ii) chemiluminescence. Analyst. 2006;131(5):616–639.
34.
Brundrett RB, White EH. Synthesis and chemiluminescence of derivatives of luminol and isoluminol. J Am Chem Soc. 1974;96(24):7497–7502.
35.
Marquette CA, Blum LJ. Applications of the luminol chemiluminescent reaction in analytical chemistry. Anal Bioanal Chem. 2006;385(3):546–554.
36.
Yamaguchi M, Yoshida H, Nohta H. Luminol-type chemiluminescence derivatization reagents for liquid chromatography and capillary electrophoresis. J Chromatogr A. 2002;950(1–2):1–19.
37.
Yue L, Liu Y-J. Mechanism of AMPPD chemiluminescence in a different voice. J Chem Theory Comput. 2013;9(5):2300–2312.
38.
Qi S, Li Q, Rao W, Liu X, Yin L, Zhang H. Determining the concentration of procalcitonin using a magnetic particles-based chemiluminescence assay for the clinical diagnosis of sepsis. Anal Sci Int J Jpn Soc Anal Chem. 2013;29(8):805–810.
39.
Molinero-Fernández Á, Moreno-Guzmán M, López , Escarpa A. Magnetic bead-based electrochemical immunoassays on-drop and on-chip for procalcitonin determination: Disposable tools for clinical sepsis diagnosis. Biosensors. 2020;10(6):66.
40.
Zhang T, Ren X, Fan D, Kuang X, Wang H, Wu D, Wei Q. Electrochemical procalcitonin immunoassay based on Au@Ag heterojunction nanorods as labels and CeO-CuO nanorods as enhancer. Sens Actuators B Chem. 2019;297: 126800.
41.
Jia Y, Yang L, Xue J, Zhang N, Fan D, Ma H, Ren X, Hu L, Wei Q. Bioactivity-protected electrochemiluminescence biosensor using gold nanoclusters as the low-potential luminophor and Cu2S snowflake as co-reaction accelerator for procalcitonin analysis. ACS Sens. 2019;4(7):1909–1916.
42.
Ding Z, Quinn BM, Haram SK, Pell LE, Korgel BA, Bard AJ. Electrochemistry and electrogenerated chemiluminescence from silicon nanocrystal quantum dots. Science. 2002;296(5571):1293–1297.
43.
Poznyak SK, Talapin DV, Shevchenko EV, Weller H. Quantum dot chemiluminescence. Nano Lett. 2004;4(4):693–698.
44.
Tao S, Feng T, Zheng C, Zhu S, Yang B. Carbonized polymer dots: A brand new perspective to recognize luminescent carbon-based nanomaterials. J Phys Chem Lett. 2019;10(17):5182–5188.
45.
Qian Y, Feng J, Wang H, Fan D, Jiang N, Wei Q, Ju H. Sandwich-type signal-off photoelectrochemical immunosensor based on dual suppression effect of PbS quantum dots/Co3O4 polyhedron as signal amplification for procalcitonin detection. Sens Actuators B Chem. 2019;300: 127001.
46.
Feng J, Li F, Liu L, Liu X, Qian Y, Ren X, Wang X, Wei Q. Ultrasensitive photoelectrochemical immunosensor for procalcitonin detection with porous nanoarray BiVO4/CuxS platform as advanced signal amplification under anodic bias. Sens Actuators B Chem. 2020;308: 127685.
47.
Li S, Xing Z, Feng J, Yan L, Wei D, Wang H, Wu D, Ma H, Fan D, Wei Q. A sensitive biosensor of CdS sensitized BiVO4/GaON composite for the photoelectrochemical immunoassay of procalcitonin. Sens Actuators B Chem. 2021;329: 129244.
48.
Seshadri P, Manoli K, Schneiderhan-Marra N, Anthes U, Wierzchowiec P, Bonrad K, di Franco C, Torsi L. Low-picomolar, label-free procalcitonin analytical detection with an electrolyte-gated organic field-effect transistor based electronic immunosensor. Biosens Bioelectron. 2018;104:113–119.
49.
Fang J, Li J, Feng R, Yang L, Zhao L, Zhang N, Zhao G, Yue Q, Wei Q, Cao W. Dual-quenching electrochemiluminescence system based on novel acceptor CoOOH@au NPs for early detection of procalcitonin. Sens Actuators B Chem. 2021;332: 129544.
50.
Chen P, Xia F, Tian D, Zhou C. A dual-coreactants electrochemiluminescent immunosensor for procalcitonin detection based on CdS-MoS2 nanocomposites. J Electrochem Soc. 2018;165(5):B196–B201.
51.
Zhang N, Feng J, Zhao G, Duan X, Wang Y, Zhang D, Wei Q. Ultrasensitive photochemical immunosensor based on flowerlike SnO2/BiOI/Ag2S composites for detection of procalcitonin. Biosensors. 2021;11(11):421.
52.
Huang J, Cheng W, Li Y. 3D carbonized wood-based integrated electrochemical immunosensor for ultrasensitive detection of procalcitonin antigen. Talanta. 2022;238: 122991.
53.
Li N-L, Jia L-P, Ma R-N, Jia WL, Lu YY, Shi SS, Wang HS. A novel sandwiched electrochemiluminescence immunosensor for the detection of carcinoembryonic antigen based on carbon quantum dots and signal amplification. Biosens Bioelectron. 2017;89:453–460.
54.
Song C, Li X, Hu L, Shi T, Wu D, Ma H, Zhang Y, Fan D, Wei Q, Ju H. Quench-type electrochemiluminescence immunosensor based on resonance energy transfer from carbon nanotubes and au-nanoparticles-enhanced g-C3N4 to CuO@polydopamine for procalcitonin detection. ACS Appl Mater Interfaces. 2020;12(7):8006–8015.
55.
Selimoğlu F, Gür B, Ayhan ME, Gür F, Kalita G, Tanemura M, Alma MH. Silver nanoparticle doped graphene-based impedimetric biosensor towards sensitive detection of procalcitonin. Mater Chem Phys. 2023;297: 127339.
56.
Liu Y, Chen F, Bao L, Hai W. Construction of a non-enzymatic electrochemical sensor based on graphitic carbon nitride nanosheets for sensitive detection of procalcitonin. RSC Adv. 2022;12(35):22518–22525.
57.
Li X, Du Y, Xu P. Signal-off electrochemiluminescence immunosensor based on Mn-eumelanin coordination nanoparticles quenching PtCo-CuFe2O4-reduced graphene oxide enhanced luminol. Sens Actuators B Chem. 2020;323: 128702.
58.
Zupančič U, Jolly P, Estrela P, Moschou D, Ingber DE. Graphene enabled Low-noise surface chemistry for multiplexed sepsis biomarker detection in whole blood. Adv Funct Mater. 2021;31(16):2010638.
59.
Wang G, Wan Y, Lin G, Li Z, Dong Z, Liu T. Development of a novel chemiluminescence immunoassay for the detection of procalcitonin. J Immunol Methods. 2020;484–485: 112829.
60.
Yin B, Yue W, Sohan ASMMF, Wan X, Zhou T, Shi L, Qian C, Lin X. Construction of a desirable hyperbolic microfluidic chip for ultrasensitive determination of PCT based on chemiluminescence. J Mater Chem B. 2023;11(9):1978–1986.
61.
Huang E, Huang D, Wang Y, Cai D, Luo Y, Zhong Z, Liu D. Active droplet-array microfluidics-based chemiluminescence immunoassay for point-of-care detection of procalcitonin. Biosens Bioelectron. 2022;195: 113684.
62.
Bhattacharyya A, Klapperich CM. Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples. Biomed Microdevices. 2007;9(2):245–251.
63.
Li H, Zhao M, Liu W, Chu W, Guo Y. Polydimethylsiloxane microfluidic chemiluminescence immunodevice with the signal amplification strategy for sensitive detection of human immunoglobin G. Talanta. 2016;147:430–436.
64.
Dart J, Setterfield J, Groves RW, Mee JB, Diercks GFH, Pas HH, Minassian D, Booth D, Reid E, Carnt N, et al. Autoantibody detection for diagnosis in direct immunofluorescence-negative mucous membrane pemphigoid. Ophthalmology. 2021;128(3):372–382.
65.
Odell ID, Cook D. Immunofluorescence techniques. J Invest Dermatol. 2013;133(1):1–4.
66.
Bossuyt X, Claessens J, De Langhe E. Antinuclear antibodies by indirect immunofluorescence and solid phase assays. Ann Rheum Dis. 2020;79(6):e65–e65.
67.
Yun H, Park JW, Min KC, Kim JK. Inflammatory dysfunction in hepatitis B-positive individuals: Quantitative assessment of C-reactive protein (CRP) and Procalcitonin (PCT) levels using immunofluorescence assay. Asia-Pac J Converg Res Interchange. 2023;9(9):323–335.
68.
Molinero-Fernández Á, Moreno-Guzmán M, Arruza L, López , Escarpa A. Polymer-based micromotor fluorescence immunoassay for on-the-move sensitive procalcitonin determination in very low birth weight infants' plasma. ACS Sens. 2020;5(5):1336–1344.
69.
Cho Y, Seo J, Sim Y, Chung J, Park CE, Park CG, Kim D, Chang JB. FRACTAL: Signal amplification of immunofluorescence via cyclic staining of target molecules. Nanoscale. 2020;12(46):23506–23513.
70.
Liu B, Lu S, Yang K, Dou X, Feng X, Cui H, Li F, Tian F. Two strategies for rapid and sensitive detection of procalcitonin using carbon dots-encapsulated nanocapsule and magnetic carbon dots as coupled labels. Chem Eng J. 2023;472: 145038.
71.
Schreiber CL, Li D-H, Smith BD. High-performance near-infrared fluorescent secondary antibodies for immunofluorescence. Anal Chem. 2021;93(7):3643–3651.
72.
Bravin C, Amendola V. Wide range detection of C-reactive protein with a homogeneous immunofluorimetric assay based on cooperative fluorescence quenching assisted by gold nanoparticles. Biosens Bioelectron. 2020;169: 112591.
73.
Gan SD, Patel KR. Enzyme immunoassay and enzyme-linked immunosorbent assay. J Invest Dermatol. 2013;133(9):1–3.
74.
Peng P, Liu C, Li Z, Xue Z, Mao P, Hu J, Xu F, Yao C, You M. Emerging ELISA derived technologies for in vitro diagnostics. TrAC Trends Anal Chem. 2022;152: 116605.
75.
Aydin S. A short history, principles, and types of ELISA, and our laboratory experience with peptide/protein analyses using ELISA. Peptides. 2015;72:4–15.
76.
Lai Y, Feldman KL, Clark RSB. Enzyme-linked immunosorbent assays (ELISAs). Crit Care Med. 2005;33(Supp l):S433–S434.
77.
Nilsson B. Enzyme-linked immunosorbent assays. Curr Opin Immunol. 1989;2(6):898–904.
78.
Yang F, Xu L, Dias ACP, Zhang X. A sensitive sandwich ELISA using a modified biotin-streptavidin amplified system for histamine detection in fish, prawn and crab. Food Chem. 2021;350: 129196.
79.
Guo Q, Han J-J, Shan S, Liu DF, Wu SS, Xiong YH, Lai WH. DNA-based hybridization chain reaction and biotin–streptavidin signal amplification for sensitive detection of Escherichia coli O157:H7 through ELISA. Biosens Bioelectron. 2016;86:990–995.
80.
Tabatabaei MS, Islam R, Ahmed M. Applications of gold nanoparticles in ELISA, PCR, and immuno-PCR assays: A review. Anal Chim Acta. 2021;1143:250–266.
81.
Oh S, Kim J, Tran VT, Lee DK, Ahmed SR, Hong JC, Lee J, Park EY, Lee J. Magnetic nanozyme-linked immunosorbent assay for ultrasensitive influenza a virus detection. ACS Appl Mater Interfaces. 2018;10(15):12534–12543.
82.
Rieger M, Kochleus C, Teschner D, Rascher D, Barton AK, Geerlof A, Kremmer E, Schmid M, Hartmann A, Gehlen H. A new ELISA for the quantification of equine procalcitonin in plasma as potential inflammation biomarker in horses. Anal Bioanal Chem. 2014;406(22):5507–5512.
83.
Wang Y, Liu X, Chen C, Chen Y, Li Y, Ye H, Wang B, Chen H, Guo J, Ma X. Magnetic nanorobots as maneuverable immunoassay probes for automated and efficient enzyme linked immunosorbent assay. ACS Nano. 2022;16(1):180–191.
84.
Li R, Liu Q, Jin Y, Li B. Fluorescent enzyme-linked immunoassay strategy based on enzyme-triggered in-situ synthesis of fluorescent copper nanoclusters. Sens Actuators B Chem. 2019;281:28–33.
85.
Ma J, Peng Z, Ma L, Diao L, Shao X, Zhao Z, Liu L, Zhang L, Huang C, Liu M. A multiple-target simultaneous detection method for immunosorbent assay and immunospot assay. Anal Chem. 2022;94(24):8704–8714.
86.
Tampoia M, Giavarina D, Di Giorgio C, Bizzaro N. Diagnostic accuracy of enzyme-linked immunosorbent assays (ELISA) to detect anti-skin autoantibodies in autoimmune blistering skin diseases: A systematic review and meta-analysis. Autoimmun Rev. 2012;12(2):121–126.
87.
Zhang Y, Gu H, Xu H. Recent progress in digital immunoassay: How to achieve ultrasensitive, multiplex and clinical accessible detection? Sens Diagn. 2024;3:9–27.
88.
Abate MF, Ahmed MG, Li X, Yang C, Zhu Z. Distance-based paper/PMMA integrated ELISA-chip for quantitative detection of immunoglobulin G. Lab Chip. 2020;20(19):3625–3632.
89.
Mou L, Dong R, Hu B, Li Z, Zhang J, Jiang X. Hierarchically structured microchip for point-of-care immunoassays with dynamic detection ranges. Lab Chip. 2019;19(16):2750–2757.
90.
Yin B, Qian C, Wan X, Muhtasim Fuad Sohan ASM, Lin X. Tape integrated self-designed microfluidic chip for point-of-care immunoassays simultaneous detection of disease biomarkers with tunable detection range. Biosens Bioelectron. 2022;212: 114429.
91.
Yin B-F, Wan X-H, Yang M-Z, Qian C-C, Sohan ASMMF. Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections. Mil Med Res. 2022;9(1):8.
92.
Zhou Y, Tian X-L, Li Y-S, Pan FG, Zhang YY, Zhang JH, Yang L, Wang XR, Ren HL, Lu SY, et al. An enhanced ELISA based on modified colloidal gold nanoparticles for the detection of Pb(II). Biosens Bioelectron. 2011;26(8):3700–3704.
93.
Chen X, Leng Y, Hao L, Duan H, Yuan J, Zhang W, Huang X, Xiong Y. Self-assembled colloidal gold superparticles to enhance the sensitivity of lateral flow immunoassays with sandwich format. Theranostics. 2020;10(8):3737–3748.
94.
Wang R, Zeng L, Yang H, Zhong Y, Wang J, Ling S, Saeed, Yuan J, Wang S. Detection of okadaic acid (OA) using ELISA and colloidal gold immunoassay based on monoclonal antibody. J Hazard Mater. 2017;339:154–160.
95.
Wen-de W, Min L, Ming C, Li-ping L, Rui W, Hai-lan C, Fu-Yan C, Qiang M, Wan-wen L, Han-zhong C. Development of a colloidal gold immunochromatographic strip for rapid detection of Streptococcus agalactiae in tilapia. Biosens Bioelectron. 2017;91:66–69.
96.
Zhou Y, Pan F-G, Li Y-S, Zhang YY, Zhang JH, Lu SY, Ren HL, Liu ZS. Colloidal gold probe-based immunochromatographic assay for the rapid detection of brevetoxins in fishery product samples. Biosens Bioelectron. 2009;24(8):2744–2747.
97.
Xu X-X, Lei X-L, Ye L-Y. Gold-based paper sensor for sensitive detection of procalcitonin in clinical samples. Chin J Anal Chem. 2022;50(4): 100062.
98.
Jiao F, Song B, Wang L, Zhou H, Zhou X, Liu T, Li X, Li J. Study on the performance of novel nanomaterials for detection of biomarkers such as PCT based on immunochromatography sensitivity. Nanotechnology. 2023;34(22): 225101.
99.
Chen R, Chen X, Zhou Y, Lin T, Leng Y, Huang X, Xiong Y. “Three-in-one” multifunctional nanohybrids with colorimetric magnetic catalytic activities to enhance immunochromatographic diagnosis. ACS Nano. 2022;16(2):3351–3361.
100.
Serebrennikova K, Samsonova J, Osipov A. Hierarchical nanogold labels to improve the sensitivity of lateral flow immunoassay. Nano-Micro Lett. 2018;10(2):24.
101.
Serebrennikova KV, Samsonova JV, Osipov AP. Enhancement of the sensitivity of a lateral flow immunoassay by using the biotin–streptavidin system. Mosc Univ Chem Bull. 2018;73(3):131–134.
102.
Huang D, Lin B, Song Y, Guan Z, Cheng J, Zhu Z, Yang C. Staining traditional colloidal gold test strips with Pt nanoshell enables quantitative point-of-care testing with simple and portable pressure meter readout. ACS Appl Mater Interfaces. 2019;11(2):1800–1806.
103.
Shao X-Y, Wang C-R, Xie C-M, Wang X-G, Liang R-L, Xu W-W. Rapid and sensitive lateral flow immunoassay method for procalcitonin (PCT) based on time-resolved immunochromatography. Sensors. 2017;17(3):480.
104.
Liao T, Yuan F, Shi C, He C-X, Li Z. Lanthanide chelate-encapsulated polystyrene nanoparticles for rapid and quantitative immunochromatographic assay of procalcitonin. RSC Adv. 2016;6(105):103463–103470.
105.
Guo J, Zhang J, Tian S, Liu K, Guo J. An up conversion optical system based on mesoporous silica encapsulated up-converting nanoparticles labeled lateral flow immunoassay for procalcitonin quantification in plasma. IEEE J Sel Top Quantum Electron. 2021;27(5):1–7.
106.
Choi S, Hwang J, Lee S, Lim DW, Joo H, Choo J. Quantitative analysis of thyroid-stimulating hormone (TSH) using SERS-based lateral flow immunoassay. Sens Actuators B Chem. 2017;240:358–364.
107.
Shi Q, Huang J, Sun Y, Yin M, Hu M, Hu X, Zhang Z, Zhang G. Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for ultrasensitive detection of antibiotics in milk. Spectrochim Acta A Mol Biomol Spectrosc. 2018;197:107–113.
108.
Wang X, Ma L, Hu C, Liu T, Sun S, Liu X, Guan M. Simultaneous quantitative detection of IL-6 and PCT using SERS magnetic immunoassay with sandwich structure. Nanotechnology. 2021;32(25): 255702.
109.
Shen H, Song E, Wang Y, Meng L, Dong J, Lin B, Huang D, Guan Z, Yang C, Zhu Z. In situ Raman enhancement strategy for highly sensitive and quantitative lateral flow assay. Anal Bioanal Chem. 2022;414(1):507–513.
110.
Xia J, Lu D, Liu Y, Ran M, Shang J, Bi L, Cao X. Prediction of premature rupture of membranes via simultaneous detection of procalcitonin and interleukin-6 by a SERS-based immunochromatographic assay. New J Chem. 2020;44(39):17099–17111.
111.
Serebrennikova KV, Samsonova JV, Osipov AP, Senapati D, Kuznetsov DV. Gold nanoflowers and gold nanospheres as labels in lateral flow immunoassay of procalcitonin. Nano Hybrids Compos. 2017;13:47–53.
112.
Chai F, Wang D, Shi F, Zheng W, Zhao X, Chen Y, Mao C, Zhang J, Jiang X. Dual functional ultrasensitive point-of-care clinical diagnosis using metal–organic frameworks-based immunobeads. Nano Lett. 2023;23(19):9056–9064.
113.
Liu J, Wang B, Huang H, Jian D, Lu Y, Shan Y, Wang S, Liu F. Quantitative ciprofloxacin on-site rapid detections using quantum dot microsphere based immunochromatographic test strips. Food Chem. 2021;335: 127596.
114.
Wei X, Chen X, Liu Z, Xu G, Chen G, Lin X, Zhan W, Huang X, Xiong Y. Advantages of aggregation-induced luminescence microspheres compared with fluorescent microspheres in immunochromatography assay with sandwich format. Anal Chim Acta. 2023;1247: 340869.
115.
Zhou S, Peng Y, Hu J, Duan H, Ma T, Hou L, Li X, Xiong Y. Quantum dot nanobead-based immunochromatographic assay for the quantitative detection of the procalcitonin antigen in serum samples. Microchem J. 2020;159: 105533.
116.
Lu Y-N, Shan Y, Huang H, Zhu L, Li B, Wang S, Liu F. Quantum dot microsphere-based immunochromatography test strip enabled sensitive and quantitative on-site detections for multiple mycotoxins in grains. Food Chem. 2022;376: 131868.
117.
Xu L-D, Zhang Q, Ding S-N, Xu J-J, Chen H-Y. Ultrasensitive detection of severe fever with thrombocytopenia syndrome virus based on immunofluorescent carbon dots/SiO2 nanosphere-based lateral flow assay. ACS Omega. 2019;4(25):21431–21438.
118.
Liu X, Liu X, Lin S, Du K, Ai Y, Wang Y. Procalcitonin measurement using antibody-conjugated fluorescent microspheres distinguishes atypical bacterial meningitis from viral encephalitis in children. Anal Biochem. 2021;626: 114219.
119.
Paloheimo L, Pajari-Backas M, Pitkänen E, Melamies L, Rissanen R. Evaluation of an immunoturbidimetric microalbuminuria assay. Clin Chem Lab Med [Internet]. 1987;25(12):1.
120.
Hernández VC, Ruiz MDP, Carrión RT, Douhal Y, Durán TP. Albumin by immunonephelometry or immunoturbidimetry? Clin Chim Acta. 2019;493:S469.
121.
Whicher JT, Price CP, Spencer K, Ward AM. Immunonephelometric and immunoturbidimetric assays for proteins. CRC Crit Rev Clin Lab Sci. 1982;18(3):213–260.
122.
Johnson AM. Nephelometric immunoassay. J Pharm Biomed Anal. 1987;5(8):803–809.
123.
Kamijo-Ikemori A, Sugaya T, Yoshida M, Hoshino S, Akatsu S, Yamazaki S, Kimura K, Shibagaki Y. Clinical utility of urinary liver-type fatty acid binding protein measured by latex-enhanced turbidimetric immunoassay in chronic kidney disease. Clin Chem Lab Med. 2016;54(10):10.
124.
Montagne P, Laroche P, Bessou T, Cuillière ML, Varcin P, Duheille J. Measurement of eleven serum proteins by microparticle-enhanced nephelometric immunoassay. Clin Chem Lab Med. 1992;30(4).
125.
Stowe H, Lawrence D, Newman DJ, Lamb EJ. Analytical performance of a particle-enhanced nephelometric immunoassay for serum cystatin C using rate analysis. Clin Chem. 2001;47(8):1482–1485.
126.
Wey L, Masetto T, Spaeth A, Brehm J, Kochem C, Reinhart M, Müller H, Kempin U, Lorenz F, Peter C, et al. Bioinformatical design and performance evaluation of a nucleocapsid- and an RBD-based particle enhanced turbidimetric immunoassay (PETIA) to quantify the wild type and variants of concern-derived immunoreactivity of SARS-CoV-2. Biomedicines. 2023;11(1):160.
127.
Borque L, Bellod L, Rus A, Seco ML, Galisteo-González F. Development and validation of an automated and ultrasensitive immunoturbidimetric assay for C-reactive protein. Clin Chem. 2000;46(11):1839–1842.
128.
Dang T, Li Z, Zhao L, Zhang W, Huang L, Meng F, Liu GL, Hu W. Ultrasensitive detection of C-reactive protein by a novel nanoplasmonic immunoturbidimetry assay. Biosensors. 2022;12(11):958.
129.
Coletta G, Amendola V. Numerical modelling of the optical properties of plasmonic and latex nanoparticles to improve the detection limit of immuno-turbidimetric assays. Nano. 2021;11(5):1147.
130.
Yang J, Zhang Y, Liu G, Zhou S, Xia Y, Li Z, Zhang C, Wang G. A highly integrated lab-on-a-disc immunoturbidimetric assay from whole blood with on-chip calibration. Microfluid Nanofluidics. 2022;26(2):10.
131.
Gao Y-Z, Zhang L, Huo W-S, Shi S, Lian J, Gao Y-H. An integrated giant magnetoresistance microfluidic immuno-sensor for rapid detection and quantification of D-dimer. Chin J Anal Chem. 2015;43(6):802–807.
132.
Yang J, Liu K, Yang M, Wang G. An immunoturbidimetric assay for specific proteins identification from whole blood based on multi-layered centrifugal microfluidic chip [Internet]. In: Wang H, editor. Eleventh International Conference on Information Optics and Photonics (CIOP 2019). Xi'an (China): SPIE; 2019.
133.
Aurora L, Snider J, Peterson E, Bryson T, Gui H, McCord J, Lanfear DE. Suppression of tumorigenicity 2 (st2) turbidimetric immunoassay and enzyme-linked immunosorbent assay: Predicting risk in heart failure. J Am Coll Cardiol. 2020;75(11):883.
134.
Rajan NK, Rajauria S, Ray T, Pennathur S, Cleland AN. A simple microfluidic aggregation analyzer for the specific, sensitive and multiplexed quantification of proteins in a serum environment. Biosens Bioelectron. 2016;77:1062–1069.
135.
Lucas LJ, Han J-H, Chesler J, Yoon J-Y. Latex immunoagglutination assay for a vasculitis marker in a microfluidic device using static light scattering detection. Biosens Bioelectron. 2007;22(9–10):2216–2222.
136.
Sun Q, Zheng W, Lin C, Shen D. A low-cost micro-volume nephelometric system for quantitative immunoagglutination assays. Sensors. 2019;19(20):4359.
137.
Bedin F, Benoit V, Ferrazzi E, Aufradet E, Boulet L, Rubens A, Dalbon P, Imbaud P. Procalcitonin detection in human plasma specimens using a fast version of proximity extension assay. PLoS One. 2023;18(2): e0281157.
138.
Van Der Hoeven AE, Van Waaij K, Bijlenga D. Hypocretin-1 measurements in cerebrospinal fluid using radioimmunoassay: Within and between assay reliability and limit of quantification. Sleep. 2022;45(7):zsac103.
139.
Ahmad S, Punzi HA, Wright KN, Groban L, Ferrario CM. Newly developed radioimmunoassay for human angiotensin-(1–12) measurements in plasma and urine. Mol Cell Endocrinol. 2021;529: 111256.
140.
Kent GN, Retallack RW. Radioimmunoassay of the basal circulating level of calcitonin in the rat. Biochem Biophys Res Commun. 1975;66(4):1251–1256.
141.
Bonamico M, Nenna R, Luparia RPL. Radioimmunological detection of anti-transglutaminase autoantibodies in human saliva: A useful test to monitor coeliac disease follow-up. Aliment Pharmacol Ther. 2008;28(3):364–370.
142.
Kim J-H, Lee S-Y, Lee S-K. Development of novel lab-on-a-chip platform for high-throughput radioimmunoassay. Appl Radiat Isot. 2021;168: 109526.
143.
Liu R, Zhang S, Wei C, Xing Z, Zhang S, Zhang X. Metal stable isotope tagging: Renaissance of radioimmunoassay for multiplex and absolute quantification of biomolecules. Acc Chem Res. 2016;49(5):775–783.
144.
Johnson J, Harris D, Pallett J, Khan S, Firoz T, Song C, Topal J, Mardh E, Sussman S. 1356: Optimization of PROCALCITONIN testing. Crit Care Med. 2020;48(1):655–655.
145.
Abers MS, Musher DM. Procalcitonin as a marker of etiology in community-acquired pneumonia. Clin Infect Dis. 2018;66(10):1639–1639.
146.
Self WH, Wunderink RG, Jain S, Edwards KM, Grijalva CG, Etiology of Pneumonia in the Community (EPIC) Study Investigators. Procalcitonin as a marker of etiology in adults hospitalized with community-acquired pneumonia. Clin Infect Dis. 2018;66(10):1640–1641.
147.
Li J, Cao T, Wei Y, Zhang N, Zhou Z, Wang Z, Li J, Zhang Y, Wang S, Wang P, et al. A review of novel cardiac biomarkers in acute or chronic cardiovascular diseases: The role of soluble ST2 (sST2), lipoprotein-associated phospholipase A2 (Lp-PLA2), myeloperoxidase (MPO), and procalcitonin (PCT). Dis Markers. 2021;2021:1–10.
148.
Vijayan AL, Vanimaya RS, Ravindran S, Saikant R, Lakshmi S, Kartik R, Manoj G. Procalcitonin: A promising diagnostic marker for sepsis and antibiotic therapy. J Intensive Care. 2017;5(1):51.
149.
Wussler D, Kozhuharov N, Oliveira MT, Bossa A, Breidthardt T, Mueller C. In reply to association of procalcitonin concentrations with pathogenic microorganisms. Clin Chem. 2020;66(10):1356–1357.
150.
Johansson N, Kalin M, Backman-Johansson C, Larsson A, Nilsson K, Hedlund J. Procalcitonin levels in community-acquired pneumonia—Correlation with aetiology and severity. Scand J Infect Dis. 2014;46(11):787–791.
151.
Cheng Z-B, Chen H. Higher incidence of acute respiratory distress syndrome in cardiac surgical patients with elevated serum procalcitonin concentration: A prospective cohort study. Eur J Med Res. 2020;25(1):11.
152.
Sandkovsky U, Kalil AC, Florescu DF. The use and value of procalcitonin in solid organ transplantation. Clin Transpl. 2015;29(8):689–696.
153.
Eschborn S, Weitkamp J-H. Procalcitonin versus C-reactive protein: Review of kinetics and performance for diagnosis of neonatal sepsis. J Perinatol. 2019;39(7):893–903.
154.
Huang M-Y, Chen C-Y, Chien J-H. Serum procalcitonin and procalcitonin clearance as a prognostic biomarker in patients with severe sepsis and septic shock. Biomed Res Int. 2016;2016:1–5.
155.
Downes KJ, Fitzgerald JC, Weiss SL. Utility of procalcitonin as a biomarker for sepsis in children. J Clin Microbiol. 2020;58(7):e01851–e01819.
156.
Aloisio E, Dolci A, Panteghini M. Procalcitonin: Between evidence and critical issues. Clin Chim Acta. 2019;496:7–12.
157.
Schuetz P, Mueller B. Procalcitonin to guide antibiotic decisions—Reply. JAMA. 2018;320(4):406.
158.
Davies J. Procalcitonin. J Clin Pathol. 2015;68(9):675–679.
159.
Sartelli M, Ansaloni L, Bartoletti M, Catena F, Cardi M, Cortese F, di Marzo F, Pea F, Plebani M, Rossolini GM, et al. The role of procalcitonin in reducing antibiotics across the surgical pathway. World J Emerg Surg. 2021;16(1):15.
160.
Kalil AC, Lisboa T. To procalcitonin, or not to procalcitonin? Chest. 2019;155(6):1085–1087.
161.
Neeser O, Branche A, Mueller B, Schuetz P. How to: Implement procalcitonin testing in my practice. Clin Microbiol Infect. 2019;25(10):1226–1230.
162.
Schuetz P, Briel M, Mueller B. Clinical outcomes associated with procalcitonin algorithms to guide antibiotic therapy in respiratory tract infections. JAMA. 2013;309(7):717.
163.
Rhee C. Using procalcitonin to guide antibiotic therapy. Open Forum Infect Dis. 2017;4(1):ofw249.
164.
Stocker M, van Herk W, el Helou S, Dutta S, Fontana MS, Schuerman FABA, van den Tooren-de Groot RK, Wieringa JW, Janota J, van der Meer-Kappelle LH, et al. Procalcitonin-guided decision making for duration of antibiotic therapy in neonates with suspected early-onset sepsis: A multicentre, randomised controlled trial (NeoPIns). Lancet. 2017;390(10097):871–881.
165.
Wolff M, Bouadma L. What procalcitonin brings to management of sepsis in the ICU. Crit Care. 2010;14(6):1007.
166.
Liu VX, Fielding-Singh V, Greene JD, Baker JM, Iwashyna TJ, Bhattacharya J, Escobar GJ. The timing of early antibiotics and hospital mortality in sepsis. Am J Respir Crit Care Med. 2017;196(7):856–863.
167.
Perner A, Gordon AC, De Backer D. Sepsis: Frontiers in diagnosis, resuscitation and antibiotic therapy. Intensive Care Med. 2016;42(12):1958–1969.
168.
Ji T, Xu X, Wang X, Cao N, Han X, Wang M, Chen B, Lin Z, Jia H, Deng M, et al. Background-free chromatographic detection of sepsis biomarker in clinical human serum through near-infrared to near-infrared upconversion immunolabeling. ACS Nano. 2020;14(12):16864–16874.
169.
Zhao W, Li J, Xue Z, Qiao X, Li A, Chen X, Feng Y, Yang Z, Wang T. A separation-sensing platform performing accurate diagnosis of jaundice in complex biological tear fluids. Angew Chem Int Ed. 2022;61(29):1.
170.
Vincent J-L, Brealey D, Libert N, Abidi NE, O'Dwyer M, Zacharowski K, Mikaszewska-Sokolewicz M, Schrenzel J, Simon F, Wilks M, et al. Rapid diagnosis of infection in the critically ill, a multicenter study of molecular detection in bloodstream infections, pneumonia, and sterile site infections. Crit Care Med. 2015;43(11):2283–2291.
171.
Ali MM, Li F, Zhang Z, Zhang K, Kang DK, Ankrum JA, Le XC, Zhao W. Rolling circle amplification: A versatile tool for chemical biology, materials science and medicine. Chem Soc Rev. 2014;43(10):3324.
172.
Gao M, Lian H, Yu L, Gong M, Ma L, Zhou Y, Yu M, Yan X. Rolling circle amplification integrated with suspension bead array for ultrasensitive multiplex immunodetection of tumor markers. Anal Chim Acta. 2019;1048:75–84.
173.
Chiang C-Y, Huang T-T, Wang C-H, Huang CJ, Tsai TH, Yu SN, Chen YT, Hong SW, Hsu CW, Chang TC, et al. Fiber optic nanogold-linked immunosorbent assay for rapid detection of procalcitonin at femtomolar concentration level. Biosens Bioelectron. 2020;151: 111871.
174.
Jing W, Wang Y, Yang Y, Wang Y, Ma G, Wang S, Tao N. Time-resolved digital immunoassay for rapid and sensitive quantitation of procalcitonin with plasmonic imaging. ACS Nano. 2019;13(8):8609–8617.
Year 2024 volume 7 Issue 4
PDF
234
129
Cite this Article
BibTeX
Article Info
doi: 10.34133/research.0345
  • Receive Date:2024-01-27
  • Online Date:2025-07-24
  • Published:2024-04-16
Article Data
Affiliations
History
  • Received:2024-01-27
  • Accepted:2024-03-04
Funding
National Natural Science Foundation of China (22307098)
Zhejiang Provincial Natural Science Foundation of China(LGF22C100003)
Wenzhou high-level innovation team(Development and application team of functional liver cancer-on-a-chip)
Wenzhou Basic Research Projects(Y2023147)
Wenzhou Institute, University of Chinese Academy of Sciences(WIUCASQD2021012)
the Scientific and Technological Innovation Major Base of Guangxi(No.2022-36-Z05)
Affiliations
    1State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-targeting Theranostics, Guangxi Key Laboratory of Bio-targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning, Guangxi 530021, P.R. China.
    2Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health); Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325000, P.R. China.
    3Joint Centre of Translational Medicine, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325035, P.R. China.
    4Department of Orthopedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopedics,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai 200025, P.R. China.

Corresponding:

* Address correspondence to: ; (Y.Z.); (L.Z.); (W.C.)
References
Share
https://castjournals.cast.org.cn/joweb/research/EN/10.34133/research.0345
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT