All the monomer conversions were performed via
1H NMR in CDCl
3 using a Bruker Avance Neo 500 MHz spectrometer at 25 °C. The molecular weights and dispersity were determined using an Agilent 1260 high performance liquid chromatography system equipped with a G7110B pump and a G7162A refractive index detector. All polymers were performed in THF solution (>99.8%, high performance liquid chromatography) at 35 °C with an elution rate of 0.5 ml min
−1. The apparent molecular weights were determined on single
photoluminescence gel MIXED-C columns using linear poly (methyl methacrylate) standards. Prior to the analysis, the sample was diluted with THF and filtered through a column of neutral alumina to remove Cu (II) and then filtered through a 0.22-μm nylon (NY) membrane filter before injecting it into the GPC columns (injection volume: 10 μl). Mechano-induced polymerization was performed in an ultrasonic bath (KUNSHAN KQ-300VDE, 45 kHz, 300 W), and the temperature was maintained in the range of 20 to 30 °C by immersing a hollow Cu cooling coil with circulating running water in the bath. The reaction device was placed in the ultrasonic bath for 1 h, and the temperature was observed until the temperature stabilized. All the conversions were measured using
1H NMR and the molecular weights were determined via GPC. The dried samples were heat pressed using an HP-100 heat-pressing machine (Hefei Kejing Material Technology Co., Ltd.) at 120 °C and 10 MPa for 10 min. The samples cooled to 25 °C spontaneously to give a hybrid material with 2-mm thickness. The ML spectra were collected from a spectrometer of Ocean Optic QE6500 with a liquid-nitrogen-cooled power detector (S7031-1006, HANANATSU). The scanning electron microscope images were obtained by a Zeiss Gemini SEM 300. The x-ray-induced luminescence patterns were obtained using an Omni-λ 300i spectrograph (Zolix) equipped with an x-ray tube (Model RACA-3, Zolix Instruments Co. Ltd., Beijing, China). The
photoluminescence images were obtained using a Hitachi F-4600 spectrophotometer equipped with an R928 photomultiplier detector. MALDI-TOF mass spectrometer was from Bruke, Germany. The MALDI instrument was equipped with a 337-nm pulsed nitrogen laser (laser intensity of 50 Hz). The number of laser irradiations was 100 for all mass spectra (delay time of 190 ns), with a 20-kV acceleration voltage. MALDI experiment was carried out using 2,5-DHB as the matrix. The matrix solution was prepared by dissolving 40 mg of 2,5-DHB in 1 ml of THF. Thermogravimetric analysis measurements were performed using a TG 209 F3 (German NETZSCH) and 80-μl aluminum oxide pans. The measurements were done under nitrogen and/or oxygen (quality 5.0) atmosphere and a gas flow of 50 ml/min for both gases. The heating rates was 10 °C/min.