White-light interferometry is widely employed in precision manufacturing sectors, including semiconductor processing, thin-film thickness measurement, and metal defect detection, owing to its merits of high precision, high measurement speed, and non-contact nature. The frequency domain analysis (FDA) technique has been applied to surface profile measurement by utilizing the slope of the phase distribution of the white-light scanning interference signal in the wavenumber domain. Through simulations and experiments, this study demonstrates that the accuracy of the phase obtained in the wavenumber domain is related to the amplitude distribution, whether in the presence of additive noise or phase noise, and quantitatively provides the optimal phase selection range for the FDA method. When the sample has strong spectral absorption, parts of the amplitude distribution in the wavenumber domain decrease significantly, rendering the corresponding phase information invalid and unreliable. To address this limitation, an improved algorithm is proposed in this paper, which incorporates the wavenumber-domain amplitude as a weighting factor into the least-squares fitting procedure. This method avoids the selection of the phase range for the FDA method and ensures high measurement accuracy.
In the simulation, the zero-mean Gaussian noise with a standard deviation (STD) of 10 nm is used as the phase noise εn(z) to generate a white-light interference signal. The Fourier transform is performed on the signal to obtain the amplitude IF(
The simulation results indicate that when only phase noise exists, the accuracy of phase extraction improves with the increase in the amplitude corresponding to the selected phase, thereby enhancing the overall measurement precision. However, the phase extraction accuracy has an upper limit. When the range
To verify the feasibility of the AOFDA method for interference signals with complex spectral distributions, a band-stop filter spectral distribution was used as the absorption spectrum of the measured object in the simulation. In the band-stop range, simulations with different reflectivities were conducted to investigate the measurement accuracy. When the reflectivity of the sample is ≥20%, it exerts little influence on the measurement accuracy of the FDA method. However, the reflectivity of <20% moves the measurement results away from their true values. When the reflectivity of the sample is <20%, the measurement results obtained by the AOFDA method always exhibit better performance. This indicates that the measurement accuracy of the AOFDA method is largely unaffected by the absorption spectrum of the sample.
The flat surface of wedged window and the step surface were measured in the experiment. When the different value of C is selected to obtain the surface profile of the wedged window, the C=0.5 has the better performance that agrees with simulation result. The Sz of the wedged window surface calculated by the AOFDA method and the FDA method (C=0.5) are 34.6 nm and 50.2 nm, and the Sq are 5.5 nm and 6.7 nm, respectively. The average step heights, whose value is regarded as 3.0 μm, of 10 measurements calculated by the AOFDA method and the FDA method (C=0.5) are 3.0054 μm and 2.9566 μm, and the repeatability values are 17.9 nm and 19.4 nm, respectively. The experimental results demonstrate that the AOFDA method can achieve the measurement accuracy comparable to that of the FDA method when selecting the optimal wavenumber-domain phase range. Since the selection of an appropriate wavenumber-domain phase range is no longer required for the AOFDA method, it enables the white-light interferometer to better adapt to complex measurement environments.
The measurement accuracy of the FDA method is degraded by environmental vibration and background noise. This work confirms that the measurement precision of the FDA method is correlated with the amplitude distribution in the wavenumber domain through the selection of diverse phase ranges, and proposes a feasible phase selection strategy to enhance its measurement performance. It is verified that the FDA method is difficult to adapt to the situation where the sample has a strong absorption spectrum. To address these limitations, the AOFDA method is developed in this paper, which incorporates the wavenumber-domain amplitude distribution as a weighting function into the phase fitting procedure. The AOFDA method can achieve a measurement accuracy comparable to that of the FDA method processed with the optimal phase range, while eliminating the need for determination of the optimal phase range.
| 科 Family | 属数 Number of genus | 种数 Number of species | 占总种数比例 Percentage of total species (%) | 属 Genus | 种数 Number of species | 占总种数比例 Percentage of total species (%) |
|---|---|---|---|---|---|---|
| 鹅膏菌科Amanitaceae | 2 | 11 | 5.26 | 鹅膏菌属 Amanita | 10 | 4.78 |
| 小菇科 Mycenaceae | 2 | 12 | 5.74 | 丝盖伞属 Inocybe | 5 | 2.39 |
| 多孔菌科 Polyporaceae | 8 | 14 | 6.70 | 蜡蘑属 Laccaria | 5 | 2.39 |
| 红菇科 Russulaceae | 3 | 23 | 11.00 | 小皮伞属 Marasmius | 6 | 2.87 |
| 小菇属 Mycena | 11 | 5.26 | ||||
| 光柄菇属 Pluteus | 5 | 2.39 | ||||
| 红菇属 Russula | 17 | 8.13 | ||||
| 栓菌属 Trametes | 5 | 2.39 |