收藏切换
Endoscopic OCT/OCTA imaging and applications in a continuous proximal scanning scheme
收藏切换
Guangsen Jia, Zehua Guan, Ping Si, Ruiming Kong, Chen Niu, Wenjuan Wu, Cuixia Dai
Opto-Electronic Engineering | 2026, 53(5) : 250325 - 1
Less
收藏切换
Opto-Electronic Engineering | 2026, 53(5): 250325-1
• Article •
Endoscopic OCT/OCTA imaging and applications in a continuous proximal scanning scheme
Full
Guangsen Jia, Zehua Guan, Ping Si, Ruiming Kong, Chen Niu, Wenjuan Wu, Cuixia Dai
Affiliations
  • Shanghai Institute of Technology, College of Sciences, Shanghai 201418, China
Published: 2026-05-26 doi: 10.12086/oee.2026.250325
Outline
收藏切换
Objective

Narrow-lumen organs, including the urethra, bladder, esophagus, gastrointestinal tract, and blood vessels, are highly susceptible to pathological remodeling processes associated with inflammation, fibrosis, neovascularization, and microcirculatory dysfunction. Early-stage diseases occurring in these organs, such as urethral stricture, bladder cancer, esophageal lesions, and vascular abnormalities, are often accompanied by subtle structural alterations and local hemodynamic changes before obvious morphological narrowing becomes clinically detectable. Therefore, high-resolution visualization of tissue microstructure and microvascular perfusion is of great importance for early diagnosis, disease monitoring, and treatment evaluation. Conventional imaging modalities, including white-light endoscopy, ultrasound endoscopy, retrograde urethrography, and fluorescence imaging, still face limitations in simultaneously assessing tissue morphology and microcirculation. Endoscopic optical coherence tomography (OCT) provides micron-scale cross-sectional imaging of biological tissues, while optical coherence tomography angiography (OCTA) further enables label-free visualization of blood flow and microvascular networks. Compared with distal motor-driven probes, proximally controlled endoscopic OCT probes possess advantages in miniaturization, structural simplicity, and mechanical flexibility, making them more suitable for narrow and deformable luminal organs. However, proximally controlled endoscopic imaging systems are highly susceptible to non-uniform rotational distortion (NURD), rotational instability, and motion artifacts, which significantly degrade OCTA image quality and vascular visualization performance. In this study, a proximally controlled endoscopic OCT/OCTA system was developed and optimized for stable multi-organ in vivo imaging and pathological assessment in complex luminal environments.

Methods

A swept-source OCT/OCTA imaging system centered at 1310 nm was employed in this study. The system achieved an axial resolution of 7.46 μm and a lateral resolution of approximately 15 μm. A side-viewing proximally controlled endoscopic probe was designed using a single-mode optical fiber, a GRIN lens, and a micro-reflector to achieve circumferential luminal imaging. To improve OCTA imaging stability under rotational scanning conditions, a complementary NURD correction strategy combined with a helical B-scan acquisition scheme was implemented to suppress rotational artifacts and improve inter-frame registration accuracy. Optical simulations were further performed using ZEMAX software to optimize probe focusing performance, working distance, and assembly tolerance.

To validate imaging capability, multilayer adhesive tape samples were first imaged to evaluate structural resolution and imaging stability. Subsequently, in vivo OCT/OCTA imaging experiments were conducted across multiple organs and animal models, including rat rectum and esophagus imaging, mouse bladder imaging, and rabbit urethra and abdominal aorta imaging, covering digestive, urinary, and vascular systems. Furthermore, pathological imaging studies were performed using a rabbit urethral stricture model induced by electrocautery thermal injury and a C57 mouse bladder cancer model. Structural OCT images and vascular OCTA datasets were acquired simultaneously to evaluate disease-associated microstructural remodeling and microcirculatory alterations.

Results and Discussions

The optimized proximally controlled endoscopic OCT/OCTA system demonstrated stable imaging performance in multiple narrow-lumen organs with different anatomical structures and motion characteristics. Imaging results of multilayer adhesive tape samples clearly resolved layered microstructures, validating the optical focusing capability and structural imaging performance of the designed probe.

In vivo imaging experiments further demonstrated that the system could reliably visualize multilayer tissue architectures, including mucosal, submucosal, and muscular layers, in the rat rectum and esophagus. OCTA imaging successfully revealed superficial microvascular networks distributed within the mucosal and submucosal regions. In mouse bladder imaging, clear structural delineation of bladder wall layers and vascular distribution was achieved despite bladder deformation and motion. Imaging of rabbit abdominal aorta further demonstrated the capability of the system for vascular lumen imaging under pulsatile conditions.

For pathological imaging applications, rabbit urethral stricture tissues exhibited obvious structural remodeling characterized by urethral wall thickening, disordered layered morphology, and localized arc-shaped hyperreflective bands associated with fibrosis formation. Correspondingly, OCTA imaging revealed reduced vascular density, interrupted vascular continuity, and localized hypoperfusion within stenotic regions, indicating progressive microcirculatory impairment during fibrosis progression. In the C57 mouse bladder cancer model, tumor-bearing tissues displayed irregular surface morphology, heterogeneous scattering features, decreased vascular density, and disorganized vascular architecture, reflecting tumor-associated angiogenic remodeling and microvascular disruption.

Compared with conventional endoscopic imaging modalities, the developed endoscopic OCT/OCTA system provides simultaneous visualization of tissue microstructure and microvascular perfusion with micron-scale spatial resolution and without the need for exogenous contrast agents. The complementary NURD correction strategy significantly improved OCTA image stability and vascular continuity in rotational scanning environments, enhancing the applicability of proximally controlled endoscopic OCTA in deformable and dynamically moving luminal organs. These results demonstrate the capability of the system for reliable detection of disease-associated structural abnormalities and hemodynamic alterations in complex narrow-lumen environments.

Conclusions

In summary, this study developed and optimized a proximally controlled endoscopic OCT/OCTA imaging system for multi-organ in vivo imaging and pathological assessment in narrow-lumen organs. The system demonstrated robust adaptability to complex anatomical and dynamic imaging environments and enabled simultaneous visualization of tissue microstructure and microvascular perfusion across digestive, urinary, and vascular systems. Pathological imaging experiments further verified the capability of the system for detecting fibrosis-associated hypoperfusion and tumor-related vascular remodeling. These findings indicate that proximally controlled endoscopic OCT/OCTA possesses significant potential for early, minimally invasive diagnosis, dynamic disease monitoring, and intraoperative guidance in luminal organ diseases.

optical coherence tomography  /  optical coherence tomography angiography  /  proximal scanning catheter  /  endoscopic imaging system  /  miniature endoscopic catheter
贾广森, 管泽华, 司平, 孔瑞明, 牛晨, 吴文娟, 戴翠霞. 近端控制内窥OCT/OCTA成像及应用研究. 光电工程, 2026 , 53 (5) : 250325 -1 . DOI: 10.12086/oee.2026.250325
Guangsen Jia, Zehua Guan, Ping Si, Ruiming Kong, Chen Niu, Wenjuan Wu, Cuixia Dai. Endoscopic OCT/OCTA imaging and applications in a continuous proximal scanning scheme[J]. Opto-Electronic Engineering, 2026 , 53 (5) : 250325 -1 . DOI: 10.12086/oee.2026.250325
Year 2026 volume 53 Issue 5
119
52
Cite this Article
BibTeX
Article Info
doi: 10.12086/oee.2026.250325
  • Receive Date:2025-10-30
  • Online Date:2026-10-22
  • Published:2026-05-26
Article Data
Affiliations
History
  • Received:2025-10-30
  • Revised:2026-01-22
  • Accepted:2026-01-23
Affiliations
    Shanghai Institute of Technology, College of Sciences, Shanghai 201418, China

Corresponding:

References
Share
https://castjournals.cast.org.cn/joweb/oee/EN/10.12086/oee.2026.250325
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT