Experimental study on optimization of liquid separation device in transport refrigeration unit
Full
Siqi CUI, Kaikun WANG, Jing BAI, Mingzhi CHEN, Bobo LI, Tianzhen ZHANG, Huifan ZHENG, Kexuan GU
Affiliations
  • School of Smart Energy and Environment,Zhongyuan University of Technology,Zhengzhou 450007,China
Published: 2026-04-30 doi: 10.3969/j.issn.1005-0329.2026.04.003
Outline
收藏切换

To address the issue of uneven refrigerant flow distribution in conventional venturi type liquid separators under low evaporation temperature conditions,as well as the resulting technical bottlenecks in transport refrigeration units operating in freezing mode,such as insufficient cooling capacity and excessively high discharge temperature,a liquid separation device with gas‑liquid separation functionality was designed.This device replaced the original venturi type liquid separator in the unit.A performance test bench was constructed,and experimental tests were conducted under both refrigeration mode and freezing mode.The experimental results indicate that compared with the original unit using the venturi type liquid separator,the unit equipped with the new liquid separator exhibited a significant increase in cooling capacity with increasing bypass regulating valve opening,while the discharge temperature first increased and then decreased.At a bypass regulating valve opening of 20%,the cooling capacity in refrigeration mode increased by 30.6% accompanied by a discharge temperature rise of approximately 6 ℃,while in freezing mode the cooling capacity increased by 38.6% accompanied by a discharge temperature rise of approximately 4 ℃.At a bypass regulating valve opening of 40%,the cooling capacity in refrigeration mode increased by 21.0% with a discharge temperature decrease of approximately 11 ℃,while in freezing mode the cooling capacity increased by 16.0% with a discharge temperature decrease of approximately 10 ℃.This study provides a technical solution for the efficient and stable operation of transport refrigeration units.

refrigeration unit  /  liquid separator  /  optimization  /  cooling capacity  /  discharge temperature
崔四齐, 王凯坤, 白静, 陈明志, 李博博, 张天臻, 郑慧凡, 谷可轩. 运输用制冷机组中分液装置优化的试验研究. 流体机械, 2026 , 54 (4) : 19 -25 . DOI: 10.3969/j.issn.1005-0329.2026.04.003
Siqi CUI, Kaikun WANG, Jing BAI, Mingzhi CHEN, Bobo LI, Tianzhen ZHANG, Huifan ZHENG, Kexuan GU. Experimental study on optimization of liquid separation device in transport refrigeration unit[J]. Fluid Machinery, 2026 , 54 (4) : 19 -25 . DOI: 10.3969/j.issn.1005-0329.2026.04.003
Year 2026 volume 54 Issue 4
51
17
Cite this Article
BibTeX
Article Info
doi: 10.3969/j.issn.1005-0329.2026.04.003
  • Receive Date:2025-08-05
  • Online Date:2026-10-22
  • Published:2026-04-30
Article Data
Affiliations
History
  • Received:2025-08-05
  • Revised:2026-03-17
Affiliations
    School of Smart Energy and Environment,Zhongyuan University of Technology,Zhengzhou 450007,China
References
Share
https://castjournals.cast.org.cn/joweb/ltjx/EN/10.3969/j.issn.1005-0329.2026.04.003
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT