To address the heating capacity degradation caused by outdoor unit frosting during winter operation of air‑source heat pumps,an electric heater was installed at the inlet pipe of the outdoor heat exchanger to elevate evaporation temperature,delay frosting,and reduce defrosting frequency. Experimental prototypes were tested to compare system performance with/without the electric heater,analyze differences between constant operating parameters and automatic adjustment,and investigate the effects of heater power,compressor frequency,expansion valve opening,and outdoor fan speed on heating performance.Results show that a 560 W heater extends heating duration by 15.1% and increases average heating capacity by 1.6%.Within the 0~735 W power range,heating duration linearly increases with heater power,extending by 2.4 minutes per 100 W increment.This study provides reference for defrosting optimization in air‑source heat pumps.