收藏切换
Experimental evaluation of hydrocarbon mixtures as alternatives in a -86 ℃ ultra-low temperature medical freezer
收藏切换
Jiarui LIU, Jianlin YU, Gang YAN
Fluid Machinery | 2025, 53(1) : 1 - 9
Less
收藏切换
Fluid Machinery | 2025, 53(1): 1-9
Experimental evaluation of hydrocarbon mixtures as alternatives in a -86 ℃ ultra-low temperature medical freezer
Full
Jiarui LIU, Jianlin YU, Gang YAN
Affiliations
  • 1School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
Published: 2025-01-30 doi: 10.3969/j.issn.1005-0329.2025.01.001
Outline
收藏切换

To address the challenges of high energy consumption and elevated global warming potential (GWP) associated with refrigerants in -86 ℃ ultra-low temperature medical freezers, this study investigates a 568 L freezer employing a single-stage mixed-refrigerant J-T refrigerator. Two ternary hydrocarbon mixtures (R600a/R170/R1150 and R601a/R290/R1150) were experimentally evaluated as environmentally friendly alternatives to the conventional fluoride-containing mixture (R600a/R23/R14/R50). The refrigeration performance of the 2 hydrocarbon blends was analyzed without changing the system components; capillary, compressor and charge adjustments were made for R601a/R290/R1150 with the aim of reducing the refrigeration temperature, compressor discharge temperature and system energy consumption. Experimental results demonstrated that, without system modifications, R600a/R170/R1150 achieved a refrigeration temperature of approximately -60 ℃, whereas R601a/R290/R1150 attained -70 ℃. After reduction of the capillary tube inner diameter and replacement of the compressor with one suitable for R290, R601a/R290/R1150 achieved a refrigeration temperature of -87.3 ℃. Compared to R600a/R23/R14/R50, this configuration reduced the maximum discharge temperature by 11.4 ℃ and energy consumption by 32.9%. However, the pull-down time to -81 ℃ increased from 246 min to 404 min. Further adjustments by increasing compressor speed and refrigerant charge shortened the cooling time to 298 min while reducing energy consumption by 28.9%. These findings confirm that R601a/R290/R1150 not only achieves sub -86 ℃ refrigeration temperatures but also exhibits superior energy efficiency and environmental benefits. Therefore, this hydrocarbon mixture presents a viable eco-friendly alternative for ultra-low temperature freezer applications.

-86 ℃ ultra-low temperature freezer  /  single-stage mixed-refrigerant J-T refrigerator  /  refrigerant alternatives  /  hydrocarbons  /  energy efficiency improvement
刘嘉瑞, 鱼剑琳, 晏刚. -86 ℃超低温医疗冷柜碳氢混合工质替代试验研究. 流体机械, 2025 , 53 (1) : 1 -9 . DOI: 10.3969/j.issn.1005-0329.2025.01.001
Jiarui LIU, Jianlin YU, Gang YAN. Experimental evaluation of hydrocarbon mixtures as alternatives in a -86 ℃ ultra-low temperature medical freezer[J]. Fluid Machinery, 2025 , 53 (1) : 1 -9 . DOI: 10.3969/j.issn.1005-0329.2025.01.001
Year 2025 volume 53 Issue 1
96
21
Cite this Article
BibTeX
Article Info
doi: 10.3969/j.issn.1005-0329.2025.01.001
  • Receive Date:2024-05-25
  • Online Date:2026-10-15
  • Published:2025-01-30
Article Data
Affiliations
History
  • Received:2024-05-25
  • Revised:2024-08-10
Affiliations
    1School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
References
Share
https://castjournals.cast.org.cn/joweb/ltjx/EN/10.3969/j.issn.1005-0329.2025.01.001
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT