收藏切换
Optimizing temporal resolution to reduce radiation dose in cerebral perfusion CT: a feasibility and stability study based on perfusion parameter assessment
收藏切换
Juntao HU1, 2, Sui LI2, Yun LIU1
Journal of Army Medical University | 2026, 48(4) : 461 - 469
Less
收藏切换
Journal of Army Medical University | 2026, 48(4): 461-469
• Clinical Medicine •
Optimizing temporal resolution to reduce radiation dose in cerebral perfusion CT: a feasibility and stability study based on perfusion parameter assessment
Full
Juntao HU1, 2, Sui LI2, Yun LIU1
Affiliations
  • 1Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing
  • 2Department of Radiology, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, China
Published: 2026-02-28 doi: 10.16016/j.2097-0927.202511101
Outline
收藏切换
Objective

To investigate the feasibility of reducing radiation dose in cerebral perfusion CT (CTP) while maintaining diagnostic accuracy by optimizing temporal resolution.

Methods

This retrospective cohort study included 117 stroke-suspected patients undergoing CTP at the First Affiliated Hospital of Army Medical University from January to September 2025. Three protocols were designed: Protocol 1 (full temporal resolution, 21-phase acquisition, baseline), Protocol 2 (every-other-phase sampling),Protocol 3 (peak-enhancement +1/-1 phase retention with every-other-phase sampling for remaining phases). Radiation reduction percentages relative to Protocol 1 were calculated. Regions of interest (ROI) were placed in ischemic core/penumbra to measure mean±SD of perfusion parameters: time to maximum of the residue function (Tmax), mean transit time(MTT), cerebral blood volume(CBV) and cerebral blood flow(CBF). Inter-protocol differences were assessed, and ischemic penumbra volume discrepancies were also analyzed.

Results

Protocol 2 and 3 reduced radiation dose by 50.0% and 42.9% versus Protocol 1, respectively. For perfusion parameters: Tmax SD differed significantly across protocols [F(1.92,222.42)=11.17, P<0.001, partial η²=0.09]; post hoc tests showed significant mean differences between Protocol 1 vs 2 (P<0.016 7) and Protocol 1 vs 3 (P<0.016 7), but not Protocol 2 vs 3. MTT means showed no significant difference [F(1.88,218.11)=0.47, partial η²=0.004] , though SD differed significantly between Protocol 1 vs 2 and 1 vs 3 (P<0.016 7). CBV SD differed significantly [F(1.98,229.25)=22.97, P<0.001, partial η²=0.17] with no mean difference (Friedman test). CBF means showed no significant difference (Bonferroni-adjusted) but SD differed significantly between Protocol 1 vs 2 and 1 vs 3 (P<0.016 7). Ischemic penumbra volumes differed significantly across all protocols (P<0.016 7).

Conclusion

Temporal resolution optimization significantly reduces CTP radiation dose while minimally impacting core perfusion parameters (MTT, CBV, CBF means). CBF remained stable across reduced-dose protocols and may serve as a reliable diagnostic criterion for infarct core delineation.

stroke  /  radiation dose  /  brain perfusion  /  tomography  /  X-Ray computed
胡钧涛, 李穗, 刘云. 优化时间分辨率以降低脑灌注CT辐射剂量:一项基于灌注参数评估的可行性与稳定性研究. 陆军军医大学学报, 2026 , 48 (4) : 461 -469 . DOI: 10.16016/j.2097-0927.202511101
Juntao HU, Sui LI, Yun LIU. Optimizing temporal resolution to reduce radiation dose in cerebral perfusion CT: a feasibility and stability study based on perfusion parameter assessment[J]. Journal of Army Medical University, 2026 , 48 (4) : 461 -469 . DOI: 10.16016/j.2097-0927.202511101
Year 2026 volume 48 Issue 4
64
25
Cite this Article
BibTeX
Article Info
doi: 10.16016/j.2097-0927.202511101
  • Receive Date:2025-11-21
  • Online Date:2026-10-23
  • Published:2026-02-28
Article Data
Affiliations
History
  • Received:2025-11-21
  • Revised:2026-01-15
Affiliations
    1Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing
    2Department of Radiology, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, China
References
Share
https://castjournals.cast.org.cn/joweb/ljjydxxb/EN/10.16016/j.2097-0927.202511101
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT