收藏切换
Improved visualization with an adjustable-light modified macroscopic on-site evaluation technique enhances specimen adequacy and diagnostic accuracy in EUS-FNA for pancreatic lesions: A randomized crossover trial
收藏切换
Xi ZHOU1, Jing SHAN1, 2, Mengyi DENG2, Dan LUO2, Ming ZHAO1, Xiaobin SUN1, Lin JIANG1
Journal of Army Medical University | 2026, 48(3) : 337 - 344
Less
收藏切换
Journal of Army Medical University | 2026, 48(3): 337-344
• Clinical Medicine •
Improved visualization with an adjustable-light modified macroscopic on-site evaluation technique enhances specimen adequacy and diagnostic accuracy in EUS-FNA for pancreatic lesions: A randomized crossover trial
Full
Xi ZHOU1, Jing SHAN1, 2, Mengyi DENG2, Dan LUO2, Ming ZHAO1, Xiaobin SUN1, Lin JIANG1
Affiliations
  • 1Department of Gastroenterology, the Third People’s Hospital of Chengdu, Chengdu ,Sichuan
  • 2College of Medicine, Southwest Jiaotong University, Chengdu, Sichuan , China
Published: 2026-02-15 doi: 10.16016/j.2097-0927.202510082
Outline
收藏切换
Objective

Determine whether a modified macroscopic on-site evaluation (MOSE) technique, by enhancing visualization of the macroscopic visible core (MVC) in 22G/25G fine needle aspiration (FNA) specimens, improves specimen adequacy and pathological diagnostic accuracy.

Methods

This single-center, prospective, randomized crossover trial enrolled 90 consecutive patients with solid pancreatic lesions scheduled for EUS-FNA from the Department of Gastroenterology at the Third People’s Hospital of Chengdu between February 2023 and August 2024. Patients were randomly assigned (1∶1) via a computer-generated sequence to Group A (first pass using traditional MOSE, second pass using modified MOSE) or Group B (first pass using modified MOSE, second pass using traditional MOSE). The core modification was the use of an adjustable white light source from 35 to 1 700 LUX at a fixed distance (37.2 mm) from the slide. Specimen adequacy was defined as MVC≥4 mm. The primary outcome was the specimen adequacy rate between groups. Secondary outcomes included the diagnostic accuracy of cytopathology and histopathology. Bias was controlled through blinded assessment (pathologists and data analysts were unaware of group allocation) and standardized operating procedures.

Results

The specimen adequacy rate was significantly higher in the modified MOSE group (70.0%, 95%CI: 59.9 to 78.5%) than in the traditional MOSE group (43.3%, 95%CI: 33.6 to 54.6%; χ²=13.714, P<0.001). The modified MOSE group also demonstrated superior diagnostic accuracy for both cytopathology [94.4%(95%CI: 87.7%~97.6%) vs 85.6%(95%CI: 76.8%~91.4%),χ2=4.9, P=0.021) and histopathology of tissue strips [95.6%(95%CI: 89.1%~98.3%) vs 83.3%(95%CI: 76.8%~91.4%),χ2=7.69, P=0.003]. Subgroup analysis based on needle gauge demonstrated that for the 22G needle, which constituted 87.8% (79/90) of cases, the modified MOSE demonstrated statistically significant advantages over the traditional MOSE in the following outcomes: specimen adequacy rate [65.8% (95%CI: 55.1% to 76.5%) vs 41.8% (95%CI: 30.7% to 52.9%), P=0.003], cytological diagnostic accuracy [93.7% (95%CI: 88.1% to 99.2%) vs 84.8% (95%CI: 76.7% to 92.9%), P=0.039], and histological diagnostic accuracy [94.9% (95%CI: 90.0% to 99.9%) vs 82.3% (95%CI: 73.7% to 90.9%), P=0.013].

Conclusion

Modified MOSE can enhance the visualization of the MVC in specimens obtained by 22G/25G FNA, thereby improving the specimen adequacy rate and pathological diagnostic accuracy.

endoscopic ultrasound-guided fine needle aspiration  /  pancreatic neoplasms  /  macroscopic on-site evaluation
周希, 单晶, 邓梦怡, 罗丹, 赵明, 孙晓滨, 姜琳. 采用可调节光源改良宏观现场评估技术可显著提升EUS-FNA胰腺标本充足率与诊断准确率:一项随机交叉对照试验. 陆军军医大学学报, 2026 , 48 (3) : 337 -344 . DOI: 10.16016/j.2097-0927.202510082
Xi ZHOU, Jing SHAN, Mengyi DENG, Dan LUO, Ming ZHAO, Xiaobin SUN, Lin JIANG. Improved visualization with an adjustable-light modified macroscopic on-site evaluation technique enhances specimen adequacy and diagnostic accuracy in EUS-FNA for pancreatic lesions: A randomized crossover trial[J]. Journal of Army Medical University, 2026 , 48 (3) : 337 -344 . DOI: 10.16016/j.2097-0927.202510082
Year 2026 volume 48 Issue 3
68
31
Cite this Article
BibTeX
Article Info
doi: 10.16016/j.2097-0927.202510082
  • Receive Date:2025-10-27
  • Online Date:2026-10-23
  • Published:2026-02-15
Article Data
Affiliations
History
  • Received:2025-10-27
  • Revised:2025-12-04
Affiliations
    1Department of Gastroenterology, the Third People’s Hospital of Chengdu, Chengdu ,Sichuan
    2College of Medicine, Southwest Jiaotong University, Chengdu, Sichuan , China
References
Share
https://castjournals.cast.org.cn/joweb/ljjydxxb/EN/10.16016/j.2097-0927.202510082
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT