收藏切换
Influence of VFTO amplitude on electrical insulation performance of EPDM for power cable terminals in GIS
收藏切换
PDF
Weihong HAN1, Chaosheng LI1, Xiaoping ZHAO1, Hongwei SU2, Jian WEI2
Insulating Materials | 2026, 59(4) : 78 - 84
Less
收藏切换
Insulating Materials | 2026, 59(4): 78-84
Insulation Technology
Influence of VFTO amplitude on electrical insulation performance of EPDM for power cable terminals in GIS
Full
Weihong HAN1, Chaosheng LI1, Xiaoping ZHAO1, Hongwei SU2, Jian WEI2
Affiliations
  • 1State Grid Gansu Electric Power Company Wuwei Electric Power Supply Company, Wuwei 733000, China
  • 2Hubei Anyuan Safety and Environmental Protection Technology Co., Ltd., Wuhan 430021, China
Published: 2026-04-20 doi: 10.16790/j.cnki.1009-9239.im.2026.04.010
Outline
收藏切换

In this paper, a very fast transient overvoltage (VFTO) discharge simulation experiment platform was established. The effect of VFTO on power equipment was simulated by multiple lightning shock waves, and the effect of discharge amplitude on the electrical insulation performance of ethylene propylene diene monomer (EPDM) was studied. The results show that after 200 times of pulsed discharges, carboxylate salt groups are formed on the EPDM surface, and the dielectric constant and dielectric loss factor increase, while the AC electric strength and surface water contact angle decrease significantly. The degradation degree of above performance increases with the increase of discharge electric field strength. When the field strength reaches 40 kV/mm, the AC electric strength of the EPDM sample decreases from 42.28 kV/mm to 37.16 kV/mm after 200 times of pulse discharges, with a decrease of 12.11%, and the water contact angle decreases from 100.53° to 88.63°.

VFTO  /  EPDM  /  AC electric strength  /  water contact angle
Weihong HAN, Chaosheng LI, Xiaoping ZHAO, Hongwei SU, Jian WEI. Influence of VFTO amplitude on electrical insulation performance of EPDM for power cable terminals in GIS[J]. Insulating Materials, 2026 , 59 (4) : 78 -84 . DOI: 10.16790/j.cnki.1009-9239.im.2026.04.010
Year 2026 volume 59 Issue 4
PDF
71
41
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2026.04.010
  • Receive Date:2025-08-07
  • Online Date:2026-09-10
  • Published:2026-04-20
Article Data
Affiliations
History
  • Received:2025-08-07
  • Revised:2025-09-08
Affiliations
    1State Grid Gansu Electric Power Company Wuwei Electric Power Supply Company, Wuwei 733000, China
    2Hubei Anyuan Safety and Environmental Protection Technology Co., Ltd., Wuhan 430021, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2026.04.010
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT