Insulating Materials | 2022, 55(5): 108-114
Test and Analysis
Research on Judgment Method of Insulation Vulnerable Spot for Low-voltage Random-wound Inverter-fed Motor Based on Three-curve Method
Full
Chizhou CHENG, Peng WANG, Xinting LIU, Yang SHI, Houlin GUO, Shakeel AKRAM
Affiliations
  • College of Electrical Engineering, Sichuan University, Chengdu 610065, China
Published: 2022-05-20 doi: 10.16790/j.cnki.1009-9239.im.2022.05.016
Outline
收藏切换

The partial discharge inception voltage (PDIV) of the turn-to-turn insulation for low-voltage random-wound inverter-fed motor changes with the rise time of pulse voltage, resulting in that it is difficult to find the vulnerable spot of the insulation system when the rise time changes. Therefore, considering the rise time of pulse width modulation, we proposed a three-curve method to determine the insulation vulnerable spot of inverter-fed motors by combining the PDIV test technology under repetitive pulse and sinusoidal voltages. At first, the minimum PDIV distributions of main insulation and phase-to-phase insulation were obtained by testing their PDIV under the sinusoidal voltage. Then, the turn-to-turn insulation of inverter-fed motor was conducted PDIV tests using the repetitive pulse voltage with 50-200 ns of rising time, and the fitting curves of PDIV with rising time were obtained. At last, according to the three-curve diagrams, considering the rise time of motor, the vulnerable spot of insulation system was determined, and the feasibility of three-curve method was verified by breakdown experiment. The results show that the insulation vulnerable spot of low-voltage random-wound inverter-fed motor can be judged by the three-curve method, and the feasibility of the three-curve method is verified by breakdown test.

inverter-fed motors  /  insulation system  /  partial discharge  /  PDIV
Chizhou CHENG, Peng WANG, Xinting LIU, Yang SHI, Houlin GUO, Shakeel AKRAM. Research on Judgment Method of Insulation Vulnerable Spot for Low-voltage Random-wound Inverter-fed Motor Based on Three-curve Method[J]. Insulating Materials, 2022 , 55 (5) : 108 -114 . DOI: 10.16790/j.cnki.1009-9239.im.2022.05.016
Year 2022 volume 55 Issue 5
PDF
153
70
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2022.05.016
  • Receive Date:2021-05-16
  • Online Date:2025-12-22
  • Published:2022-05-20
Article Data
Affiliations
History
  • Received:2021-05-16
  • Revised:2021-06-23
Funding
Affiliations
    College of Electrical Engineering, Sichuan University, Chengdu 610065, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2022.05.016
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT