Insulating Materials | 2022, 55(3): 100-106
Test and Analysis
Study on a Pressure Correction Method for Flash Point Determination of Transformer Insulating Oil Based on 1/T-lnP Linear Relationship
Full
Shaojie ZHANG, Xinliang GUO, Xueying YANG, Xueting CHENG, Yunhua HE
Affiliations
  • Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650217, China
Published: 2022-03-20 doi: 10.16790/j.cnki.1009-9239.im.2022.03.014
Outline
收藏切换

The flash point measured value of transformer oil is significantly affected by atmospheric pressure, therefore the standard flash point value of transformer oil at 101.3 kPa need to be obtained through pressure correction on the measured value. The open-cup and closed-cup flash point value of new 25# transformer oil and used transformer oil under different air pressure was measured by flash point tester. The results indicate that there is a certain linear relationship between the reciprocal value of flash point (1/TF-exp) and the logarithm of experimental pressure (lnP). The linear expression of 1/TF-exp-lnP for each experimental oil sample is determined, and the range of 1/TF-exp-lnP slope value is (-2.31--1.22)×10-4 (for the open-cup flash point) and (-6.68--2.32)×10-5 (for the closed-cup flash point) for different oil samples. The flash point value of the experimental oil sample determined under different pressure (60.0-102.0 kPa) is corrected to the standard flash point value at 101.3 kPa, and it is found that the correction deviation is far less than the deviation caused by using the current standard method on basis of the TF-exp-P linear relationship. The correction method based on the linear relationship of 1/TF-exp-lnP has a better correction accuracy and a wider pressure range, which has good practical significance to obtain more accurate corrected flash point value of transformer insulating oil.

transformer oil  /  flash point  /  air pressure  /  correction
Shaojie ZHANG, Xinliang GUO, Xueying YANG, Xueting CHENG, Yunhua HE. Study on a Pressure Correction Method for Flash Point Determination of Transformer Insulating Oil Based on 1/T-lnP Linear Relationship[J]. Insulating Materials, 2022 , 55 (3) : 100 -106 . DOI: 10.16790/j.cnki.1009-9239.im.2022.03.014
Year 2022 volume 55 Issue 3
PDF
100
44
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2022.03.014
  • Receive Date:2021-03-18
  • Online Date:2025-12-22
  • Published:2022-03-20
Article Data
Affiliations
History
  • Received:2021-03-18
  • Revised:2021-05-05
Affiliations
    Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650217, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2022.03.014
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT