收藏切换
Influence of measurement method on PDIV test results of AI/PI enamelled rectangular magnet wire
收藏切换
PDF
Wei LIU1, Xiyun LIN1, Shiming ZHANG1, Xianglong SHEN1, Guoqing YE1, Xiaoliang FENG1, Xubin WANG1, Yuanju LI2
Insulating Materials | 2023, 56(8) : 115 - 118
Less
收藏切换
Insulating Materials | 2023, 56(8): 115-118
Test and Analysis
Influence of measurement method on PDIV test results of AI/PI enamelled rectangular magnet wire
Full
Wei LIU1, Xiyun LIN1, Shiming ZHANG1, Xianglong SHEN1, Guoqing YE1, Xiaoliang FENG1, Xubin WANG1, Yuanju LI2
Affiliations
  • 1Zhejiang Xiandenglüneng New Material Co., Ltd., Xiandeng Hi-tech Electric Co., Ltd., Huzhou 313000, China
  • 2Xyno (Shanghai) Advanced Materials Co., Ltd., Shanghai 201109, China
Published: 2023-08-20 doi: 10.16790/j.cnki.1009-9239.im.2023.08.017
Outline
收藏切换

Enamelled rectangular magnet wires used in driving motor for electric vehicle need to test their partial discharge initial voltage (PDIV). However, the current IEC and national standards have no normative parameter on the PDIV test condition, and domestic motor manufacturers have different requirements on the PDIV performance. In order to obtain accurate PDIV data, the testing principle of instrument for measuring partial discharge was studied. The influence of test methods on the PDIV results of polyamide-imide and polyimide enamelled rectangular magnet wires under different voltage increase rate, determination threshold, and fitting length of wires was analyzed. The results indicate that if 10 V/s and 10 pC are taken as test condition and the fitting length of wires is more than 90 mm, the PDIV results are the closest to the theoretical value. If higher rising rate and higher threshold are used, the measured PDIV results will be higher, and the stability of test results will decrease.

driving motor for electric vehicle  /  enamelled rectangular magnet wire  /  partial discharge  /  PDIV  /  test standard
Wei LIU, Xiyun LIN, Shiming ZHANG, Xianglong SHEN, Guoqing YE, Xiaoliang FENG, Xubin WANG, Yuanju LI. Influence of measurement method on PDIV test results of AI/PI enamelled rectangular magnet wire[J]. Insulating Materials, 2023 , 56 (8) : 115 -118 . DOI: 10.16790/j.cnki.1009-9239.im.2023.08.017
Year 2023 volume 56 Issue 8
PDF
125
56
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2023.08.017
  • Receive Date:2022-10-15
  • Online Date:2025-11-24
  • Published:2023-08-20
Article Data
Affiliations
History
  • Received:2022-10-15
  • Revised:2022-12-15
Funding
Affiliations
    1Zhejiang Xiandenglüneng New Material Co., Ltd., Xiandeng Hi-tech Electric Co., Ltd., Huzhou 313000, China
    2Xyno (Shanghai) Advanced Materials Co., Ltd., Shanghai 201109, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2023.08.017
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT