收藏切换
CVT insulation status evaluation based on improved criteria importance through intercriteria correlation method
收藏切换
PDF
Pingtao DUAN, Yuan LI, Kai ZHOU, Hao YUAN, Hao ZHOU
Insulating Materials | 2025, 58(4) : 73 - 81
Less
收藏切换
Insulating Materials | 2025, 58(4): 73-81
Insulation Technology
CVT insulation status evaluation based on improved criteria importance through intercriteria correlation method
Full
Pingtao DUAN, Yuan LI, Kai ZHOU, Hao YUAN, Hao ZHOU
Affiliations
  • College of Electrical Engineering, Sichuan University, Chengdu 610065, China
Published: 2025-04-20 doi: 10.16790/j.cnki.1009-9239.im.2025.04.010
Outline
收藏切换

In order to ensure the safe and stable operation of capacitor voltage transformer (CVT), improve its insulation reliability, the insulation state of CVT was evaluated based on improved criteria importance through intercriteria correlation (CRITIC) method. Firstly, the CVT was conducted the artificially accelerated thermal ageing, and its capacitance and dielectric loss factor, polarization and depolarization current, voltage and current were tested under different ageing cycles. The results show that after ageing, the total capacitance of CVT increases from 10.106 nF to 10.155 nF, the time constant of the third branch increases from 62.35 s to 82.80 s, the current and voltage phase difference increases from 96.3° to 97.8°, and only the primary side apparent impedance value decreases among the insulation characteristic parameters. Subsequently, the CRITIC method was improved by residual expectation coefficient and activation entropy, and the improved CRITIC method was used to weight and score the CVT insulation characteristic parameters. In the empowerment results, the weight of 0.1 Hz low frequency dielectric loss factor is the largest, which is 0.323 3, and the weight of C1 dielectric loss factor is the smallest, which is 0.091 2, and the improved CRITIC method solves the problem of information incompleteness. Finally, the insulation score of CVT was correlated with the operating time under actual working condition, and its insulation status was evaluated. When the insulation score is 0 points, the corresponding operating time under working condition is 29.88 years, which is consistent with the actual project. According to CVT insulation score, the internal insulation state can be judged.

CVT  /  insulation status evaluation  /  ageing characteristics  /  improved CRITIC method  /  insulation score
Pingtao DUAN, Yuan LI, Kai ZHOU, Hao YUAN, Hao ZHOU. CVT insulation status evaluation based on improved criteria importance through intercriteria correlation method[J]. Insulating Materials, 2025 , 58 (4) : 73 -81 . DOI: 10.16790/j.cnki.1009-9239.im.2025.04.010
Year 2025 volume 58 Issue 4
PDF
119
55
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2025.04.010
  • Receive Date:2024-04-09
  • Online Date:2025-11-07
  • Published:2025-04-20
Article Data
Affiliations
History
  • Received:2024-04-09
  • Revised:2024-08-05
Funding
Affiliations
    College of Electrical Engineering, Sichuan University, Chengdu 610065, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2025.04.010
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT