收藏切换
Evaluation method for buffer layer ablation of high voltage cable based on gas stoichiometric characteristics
收藏切换
PDF
Zhigang REN1, Wei GUO1, Yekun MEN1, Jingcheng ZHANG1, Ge ZHAO2, Jian GAO2
Insulating Materials | 2025, 58(4) : 109 - 116
Less
收藏切换
Insulating Materials | 2025, 58(4): 109-116
Test and Analysis
Evaluation method for buffer layer ablation of high voltage cable based on gas stoichiometric characteristics
Full
Zhigang REN1, Wei GUO1, Yekun MEN1, Jingcheng ZHANG1, Ge ZHAO2, Jian GAO2
Affiliations
  • 1 State Grid Beijing Electric Power Research Institute, Beijing 100075, China
  • 2 State Key Laboratory of Electrical Insulation and Power Equipment, Xi′an Jiaotong University, Xi′an 710049, China
Published: 2025-04-20 doi: 10.16790/j.cnki.1009-9239.im.2025.04.014
Outline
收藏切换

The ablation of the buffer layer of high-voltage cables is accompanied by the release of characteristic gas, so the characteristic gas can be used as an indicator for the detection and evaluation of ablation faults. However, the correlation between the type and concentration of released gas and the degree of ablation is still unclear. In this paper, a buffer layer ablation simulation experiment platform was established. After comprehensive consideration, C2H6, C2H4, C2H2, and CO were selected as the characteristic gases for buffer layer ablation evaluation, and the change law of their stoichiometric characteristics with buffer layer ablation degree and moisture content were analyzed. The results show that the average molar mass of characteristic gas decreases with the increase of moisture content in buffer layer, and the ratio of C to H atoms in characteristic gases under humid conditions is higher than that under dry conditions. The concentrations of C and H atoms continuously increase with the burning time, and with the increase of burning time, the concentrations of C and H atoms first decrease, then increase and then decreases, and finally monotonically increase with the increase of moisture degree. Analysis suggests that the differences of damage to the buffer layer structure under different conditions are the reasons for the change in the stoichiometric characteristics of the released gas.

high voltage cable  /  buffer layer ablation  /  characteristic gas  /  stoichiometric characteristics
Zhigang REN, Wei GUO, Yekun MEN, Jingcheng ZHANG, Ge ZHAO, Jian GAO. Evaluation method for buffer layer ablation of high voltage cable based on gas stoichiometric characteristics[J]. Insulating Materials, 2025 , 58 (4) : 109 -116 . DOI: 10.16790/j.cnki.1009-9239.im.2025.04.014
Year 2025 volume 58 Issue 4
PDF
115
51
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2025.04.014
  • Receive Date:2024-04-24
  • Online Date:2025-11-07
  • Published:2025-04-20
Article Data
Affiliations
History
  • Received:2024-04-24
  • Revised:2024-05-15
Funding
Affiliations
    1 State Grid Beijing Electric Power Research Institute, Beijing 100075, China
    2 State Key Laboratory of Electrical Insulation and Power Equipment, Xi′an Jiaotong University, Xi′an 710049, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2025.04.014
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT