Temperature distribution characteristics of FXBW-500 composite insulator with internal carbonization creepage defect
收藏切换
PDF
Yongquan WU1, Siwei ZHANG1, Zongyi JIANG1, Yanjun JIAO1, Mincheng GAO1, Tao LONG1, Zihan GUO2, Dongdong ZHANG2
Insulating Materials | 2025, 58(2) : 102 - 109
Less
收藏切换
Insulating Materials | 2025, 58(2): 102-109
Test and Analysis
Temperature distribution characteristics of FXBW-500 composite insulator with internal carbonization creepage defect
Full
Yongquan WU1, Siwei ZHANG1, Zongyi JIANG1, Yanjun JIAO1, Mincheng GAO1, Tao LONG1, Zihan GUO2, Dongdong ZHANG2
Affiliations
  • 1Nanjing Power Supply Branch, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 210019, China
  • 2Nanjing Institute of Technology, Nanjing 211167, China
Published: 2025-02-20 doi: 10.16790/j.cnki.1009-9239.im.2025.02.014
Outline
收藏切换

Regarding the internal carbonization creepage defect of composite insulator, a finite element model of electromagnetic and thermal coupling calculation for FXBW-500 large-small-small shed type composite insulator was established, and the influencing laws of defect location and surface pollution on the temperature rise caused by internal carbonization creepage defect in core rod were analyzed. The results show that when there is a local carbonization creepage defect at different positions of composite insulators, the local temperature rise from high to low is high voltage end, low voltage end, and middle end. When there is pollution, the temperature distribution of the carbonization creepage defective insulator does not change significantly, but the maximum temperature rise values of each part all increase significantly, among which the maximum temperature rise of high voltage end increases from 9.3℃ to 18.2℃, and the temperature rise along the surface increases from 2.52℃ to 4.94℃. Although the existence of pollution makes the overall temperature of the insulator rise, it still does not conceal the temperature jump at the defect location. Therefore, when the location of carbonization creepage defects are identified through temperature, the temperature jump can be taken as a reference.

transmission lines  /  composite insulators  /  carbonization creepage  /  finite element  /  electric thermal field
Yongquan WU, Siwei ZHANG, Zongyi JIANG, Yanjun JIAO, Mincheng GAO, Tao LONG, Zihan GUO, Dongdong ZHANG. Temperature distribution characteristics of FXBW-500 composite insulator with internal carbonization creepage defect[J]. Insulating Materials, 2025 , 58 (2) : 102 -109 . DOI: 10.16790/j.cnki.1009-9239.im.2025.02.014
Year 2025 volume 58 Issue 2
PDF
126
56
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2025.02.014
  • Receive Date:2024-03-21
  • Online Date:2025-11-06
  • Published:2025-02-20
Article Data
Affiliations
History
  • Received:2024-03-21
  • Revised:2024-06-20
Funding
Affiliations
    1Nanjing Power Supply Branch, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 210019, China
    2Nanjing Institute of Technology, Nanjing 211167, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2025.02.014
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT